aXsGUARD Gatekeeper Authentication Quick Install Guide v1.6
Connecting the aXsGUARD Gatekeeper to a Network
Windows) or Terminal (Linux) and run the following command:
ping 192.168.250.254
If a reply is received as shown in the image above, everything is OK.
If a Request Timed Out or Destination Host Unreachable response is received, please check the following:
check that the workstation's TCP/IP settings have been entered correctly (see above)
check that the network cable is in good working order and correctly plugged into the device labeled 'eth0'
on the aXsGUARD Gatekeeper and your network hub or switch (see section
4.2
).
Once the workstation is correctly configured, the aXsGUARD Gatekeeper Administrator Tool can be accessed
through a browser on the workstation, as explained in the following section.
Note
Once the network settings on the aXsGUARD Gatekeeper have been configured appropriately,
(explained in section
6.6
), the workstation IP address can be reconfigured onto the network,
and the aXsGUARD Gatekeeper can be accessed from any browser on the network.
© 2009 - VASCO Data Security
16
Image 8: Command Prompt and Testing TCP/IP Settings