Symptom
Remedy
The unit does not work, no light
Check the mains connection and the fuse.
No response to the DMX con-
troller
1. If the dot behind the first character of the display is
flashing in the DMX mode, no DMX signal is received.
Make sure that the DMX controller is turned on. Check
the DMX ports and cables for proper connection.
2. If the display does not flash and still no response,
check the address settings and the DMX polarity.
3. Try using another DMX controller.
4. Check to see if the DMX cables run near or alongside
to high voltage cables that may cause damage or inter-
ference to DMX interface circuits.
If the procedures recommended above do not succeed, please contact our Service Center. You
can find the contact information at
www.thomann.de
.
Troubleshooting
BAT.PARset 4 RGBW