AGENCY APPROVALS
Safety:

UL Listed:

UL 1950 (3

rd

 Edition)

CUL Listed:

CSA No. 22.2  950

FDA:

DHHS 21 CFR Subchapter J
Accession No 0220210-00

TUV/GS

EN60950

EMI Emissions:

FCC:

CISPR 22/FCC Part 15, Subpart B, Class A

CE:

EMC 89/336/EEC, LVD 73/23/EEC
EN55022, EN55024, EN61000-3-2, EN61000-3-3,
EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN610004-8,
EN61000-4-11

CONTROLS
Front:

Power Switch

Power LED Indicator
OSD Select and Adjust

Brightness, Contrast, H-Size, H-Position,
V-Size, V-Position, Pincushion, Trapezoid,
Parallelogram, Pin Balance, rotation,
Degauss, Factory Reset, Color Adjustment,
Exit

Rear:

Remote Control Address selection switches

Remote Control:

Infrared remote control capable of adjusting

individual selectable monitors via rear mounted
DIP switches.

WEIGHTS AND DIMENSIONS

VT29B-M 

Net Weight: 117 Lbs (53 kg) 
Gross Weight: 125 Lbs (57 kg) 

Unit Dimensions:
Width: 25” (635mm) 
Height: 21.13” (537mm) 
Depth: 19.75” (502mm) 

Packed Dimensions:
Width: 32” (813mm) 
Height: 28” (711mm) 
Depth: 27” (686mm) 

 SPECIFICATIONS 

(con’td)

13

Содержание VT29B-M

Страница 1: ...to Sync Color Display User s Guide Read these instructions completely before attempting to operate your new Color Display VarTechSystemsInc Solutions for Demanding Applications Industrial CRT and Flat Panel Displays ...

Страница 2: ...f fire or electric shock do not expose this appliance to rain or moisture CAUTION To reduce the risk of electric shock do not remove cover there are no user serviceable parts inside Refer servicing to qualified service personnel The lightning bolt symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product enclosure that m...

Страница 3: ...tant Safety Instruction 3 4 Connecting the Monitor 5 PD Series Monitor Operation 6 7 Color Monitor Hand Held Remote Operation 8 Power Management Function 9 Trouble Shooting 10 CRT Specifications 11 Specifications 12 13 Appendix Timing Charts 14 1 ...

Страница 4: ...y connecting a H V meter between the anode of CRT cap and chassis Caution 1 Keep monitor away from excessive dust high temperature moisture or direct sunlight 2 Use in a well ventilated area and do not cover ventilation openings 3 Unauthorized modifications of this equipment substitution or attachment of un shielded connecting cables may cause excessive interference 4 If the monitor is not in use ...

Страница 5: ...must not be blocked or covered The openings should never be blocked by placing the product on a bed sofa rug or any similar surface This product should never be placed near or over a radiator or heat register This product should not be placed in a built in installation unless proper ventilation is provided 8 This product should be operated from the type of power source indicated on the marking lab...

Страница 6: ...ng to a service technician 14 Unplug this product from the wall outlet and refer servicing to a qualified service technician under the following conditions A When the power cord or plug is damaged or frayed B If liquid has been spilled into the product C If the product has been exposed to rain or water D If the product does not operate normally when the operating instructions are followed Adjust o...

Страница 7: ... to the monitor The monitor supports two type of signal cable HD 15 or BNC The monitor will automatically detect which input is used however only one type can be connected at a time 5 The monitor supports separate sync composite sync and sync on green When using signal with composite sync the composite sync should be connected to the H H V connector of the BNC connectors or pin 14 of the HD 15 con...

Страница 8: ...con corresponding to adjustment required Center of OSD menu displays image resolution and frequency User s Controls Power Switch Push the Power Switch to turn the monitor on and off The Power LED near the OSD adjustment switches will light when the power is on The LED will display Green when a valid signal is present Amber if the monitor is in power saving mode sig nal is interrupted from computer...

Страница 9: ...MONITOR OPERATION 7 ...

Страница 10: ...ALUES TO ACHEIVE DESIRED NUMBER After setting Binary Code Monitor Power must be cycled to activate 2 Depress two digit number on remote to correspond to address setting 3 Depress REVIEW button to activate On Screen Display OSD 4 Depress CH or CH button to select adjustment function 5 Depress or button to adjust monitor 6 Depress POWER button to save adjustments and disable remote NOTE The POWER bu...

Страница 11: ...ion of these power states and their corresponding power consumption Mode H Sync V Sync Video Power Consumption ON Pulse Pulse Active 150 W max Standby None Pulse Blanked 25 W Suspend Pulse None Blanked 25 W 1 The power management function requires TTL horizontal and vertical sync signals to operate 2 This monitor is Energy Star compliant when used with a computer with DPMS Reinitializing Power To ...

Страница 12: ... of the Activate Degauss monitor has been circuit to degauss the changed during monitor operation Signal cable is not Connect the properly connected signal cable properly RGB gain settings Adjust the RGB gain level is off Picture not stable Signal cable not Connect the can not sync properly connected signal cable properly Input signal is out of the monitor s range Set the display adapter s resolut...

Страница 13: ...CRT SPECIFICATIONS MODEL VT29B M VIEW SIZE 27 68CM DEFLECTION 110 DEG PHOSPHOR P22 DOT PITCH 0 62 MM FACEPLATE FLAT 11 ...

Страница 14: ...elects input method DO NOT CONNECT BOTH TYPES OF INPUT CABLES TO MONITOR AT SAME TIME OR DAMAGE MAY RESULT Signal Compatibility POWER Input Voltage 100V 240V 47 Hz 63 Hz Consumption 120 W Maximum Input Connector IEC 3P 3 Prong Grounded 12 MODE RESOLUTION HOR FREQ VER FREQ VGA 640X350 31 5 kHz 70 Hz 640X400 31 5 kHz 70 Hz 640X480 31 5 kHz 60 Hz 640X480 31 5 kHz 72 Hz SVGA 800X600 35 2 kHz 56 Hz 800...

Страница 15: ...ED Indicator OSD Select and Adjust Brightness Contrast H Size H Position V Size V Position Pincushion Trapezoid Parallelogram Pin Balance rotation Degauss Factory Reset Color Adjustment Exit Rear Remote ControlAddress selection switches Remote Control Infrared remote control capable of adjusting individual selectable monitors via rear mounted DIP switches WEIGHTS AND DIMENSIONS VT29B M Net Weight ...

Страница 16: ...Appendix Timing Charts 14 ...

Страница 17: ...EMS INC HEADQUARTERS 11529 Sun Belt Ct Baton Rouge Louisiana 70809 Toll Free 800 223 8050 International Phone 001 225 298 0300 Fax 225 297 2440 E mail sales vartechsystems com www vartechsystems com 150 068 3 07 05 ...

Отзывы: