An error has occurred if the value for the current (I grid)
hovers b0.01 and -0.01 on one of the connected
phases. Check the cable connection to the current sensor.
If realistic values are not displayed, check whether the
connection corresponds to a clockwise phase sequence.
Note:
The system may need to have a large load at all
three phases.
Checking the battery modules
Check whether the
Battery module serial number
of the
installed battery module is displayed.
Exiting the password-protected area
8.10.9
Finally, it is necessary to ensure that the customer is unable to
access the password-protected area.
Click on the
Logout
tab.