12
ENGLISH
IS
1. TECHNICAL DATAS
VARMA 303MOB/15X5 IPX5
Power:
1500 Watt
IPX5
Infrared Heater protected against rain
220-240V 50/60 Hz Class I
VARMA 303MOB/20X5 IPX5
Power:
2000 Watt
IPX5
Infrared Heater protected against rain
220-240V 50/60 Hz Class I
Model on mobile telescopic stand with round baseTRIPOD2.
For inside and outside areas.
Only if used indoors, the heater must be combined with STAR PROGETTI control device CODE.207 or equivalent to comply
with EU Regulation 2015/1188.
2. EQUIPMENT
Appliances VARMA 303MOB/15X5 IPX5 are supplied complete with: 5 m electric cable, schuko plug, switch, steel grid.
3.
INSTALLATION OF VARMA 303MOB/15X5 IPX5 - VARMA 303MOB/20X5 IPX5
Do not place the heater immediately under a power socket.
To get the best heating performance, the ideal positioning of the appliance is 45° inclined downwards, and the appliance
to be fixed perfectly horizontal.
4.
POSITIONING VARMA 303MOB/15X5 IPX5 - VARMA 303MOB/20X5 IPX5
Adjust the VARMA IPX5 reflector in the direction of the required heating bundle, when installing on a wall. It is usually
a 45° inclination related to the horizontal line.
The appliance must never be installed on a flammable surface, VARMA IPX5 must be placed at a safe distance (clear
space) of minimum 2.0 m. from combustible materials such as: cartons, fabrics, curtains etc. as well as glass walls.
If placed in workshops and garages where there are flammable paints and liquids, VARMA IPX5 must be placed at a
minimum distance of 4 m. from the source of danger. We suggest not to use VARMA IPX5 in particularly dusty and closed
areas. This could damage the bulb.
When mounting inside a bathroom, always respect the minimum distances from showers and baths, and ensure
compliance with CEE-CEI.
Furthermore, the commands to adjust the appliance and turn it on and off must not be within reach of the shower or
bath.
5. CLEANING
The cover and bulb must be kept clean to maintain the heater’s original heat efficiency. Use only denatured alcohol and a
clean cloth. Other products may damage the heater.
6. INSTRUCTIONS FOR REPLACING THE BULB
WARNING - The V301-V302 guarantee does not cover replacement or repair of the bulb. To change the bulb contact a
professionally qualified electrician or assistance service.
If necessary, call our Technical Service. Technical Office tel. 02/90639261
35
Содержание V303MOB
Страница 8: ...8 ITALIANO...
Страница 13: ...13 ENGLISH IS...
Страница 18: ...18 FRAN AIS IS...
Страница 23: ...23 ESPA OL...
Страница 28: ...28 DEUTSCH Kundendienstzentrum Wenden Sie sich bei Bedarf an unser technisches B ro Tel 39 02 90639261 35...
Страница 29: ...29 VARMA 303MOB IPX5 V303MOB 15X5 V303MOB 20X5 VARMA 303 IPX5 VARMA 303 IPX5 c...
Страница 30: ...30 8 3 3 8 3 8...
Страница 31: ...31 CEE CEI 5 3...
Страница 32: ...32 Star Progetti T180 a b c III...