Disassembly of the V-Series Internal Gear Pump
with Magnetic Coupling
9.
Disassembly
9.1
General
Improper or incorrect assembly and disassembly may cause pump malfunctions and result in
high repair costs and long downtimes. If you have questions or require further information, please
do not hesitate to contact VARISCO S.p.A.
!
Failure to observe these instructions and/or the warning notes may result in risks to the operator
and/or serious damage to the pump or pump unit.
VARISCO S.p.A.
shall not be held liable for
any accidents or damage caused as a result of non-observance of this manual.
The specific safety requirements in relation to strong magnetic fields must be strictly observed.
Persons who have a pacemaker should not be allowed to work on a pump with magnetic
coupling!
The magnetic field is sufficiently strong to affect a pacemaker’s proper operation. For this
reason, a safe distance of at least three (3) metres should be kept.
Always keep equipment with magnetic data carriers (memory) such as cheque cards,
computer disks, watches, etc. at a distance from the magnetic coupling (at least 1 m) because
they might be damaged and/or data loss might occur.
Prior to opening the pump, make sure that
-
it is completely depressurized
-
all its content was drained and the pump flushed
-
it was vented and allowed to cool down.