3.2 Intermediate storage/preservation
As required, pumps should be tested and set using a liquid that also serves to protect the pump’s
interior for a period of six months from the time of delivery. This liquid is a mixture of lube oil and
passivating neutral detergent.
Clean the pump prior to installation if the filled-in liquid might contaminate the product to be pumped.
Never start up the pump with water and do not leave any traces of water in the pump.
3.3 Return
Pumps that have delivered corrosive or poisonous media must be thoroughly flushed and
cleaned before they are returned to the manufacturer.
A declaration of conformity confirming that it is safe to use and a safety data sheet for the
medium must be enclosed with the returned pump (see Annex ”Certificate of Conformity“).
Please state safety precautions and decontamination measures taken.