I N S T A L L A T I O N I N S T R U C T I O N S
6
5
6
5. The air extractor pipe is in the upper right
hand corner. Secure it with a hose clamp
contained in the delivery.
You can choose to connect the high
performance sound muffler to your exhaust
air outlet pipe and also fasten it with an
additional clamp.
6. The suction pipe is located at the bottom left
hand corner of the central vacuum cleaner.
Place rubber sleeve and the remaining two
hose clamps over the suction pipe and
secure the rubber sleeve for one via the
stub and for another via the suction pipe.
The pipe section should have a length of at
least 6 cm before installing an elbow or tee.
This enables a future withdrawal of the unit.
7. Connect the 12/24 V control line from the
vacuum line to the 24 V control line of the
central vacuum cleaner. Plug in the 230 V
cable into the insulated ground receptacle.
Now the central vacuum cleaner can be
operated properly.
7