Page 10
ECS 5M
2.2 MOUNTING
Mont the control panel to the wall using the mounting
holes located on the flange of the control housing.
Once the ECS 5M is in place, use a screwdriver to
remove the six screws holding the faceplate to the
housing.
2.3 SWITCH SETTINGS
The ECS 5M is configured for a variety of options via two
switches as follows:
2.3.1 - Line Voltage
Selector Switch
This switch is
located on the surface of
the main (bottom)
board and adapts the
control
panel
for
115
VAC or 230 VAC line
voltage.
To limit the unit’s exposure to noxious gases install the
unit in a hallway.
Make certain that the unit is mounted right side up with
the cable entry holes facing down.
The ECS 5M will operate in a temperature range of 32°F -
120 °F (0 °C - 50 °C).
* It is prohibited to use overhead cables outside the building.
Mounting hardware is not shipped with the unit.
230V
115V