SH-110 Dry Scroll Vacuum Pump
22
DRAFT 3/22/07
Troubleshooting
Use the Troubleshooting chart in Table 5 to assist in defining a problem, determining a possible cause, and defining action
steps to remedy the situation.
Table 5 Troubleshooting Chart
Problem
Possible Causes
Corrective Actions
Will not start
One or both fuses blown
Replace fuses.
Identify cause of overload.
Check the line voltage and the voltage configuration of the pump.
Motor thermal protector open
Allow motor to cool.
Identify cause of overload.
Excessive voltage drop
Check size and length of cable.
Defective motor
Inspect. Contact Vacuum Technologies.
Poor ultimate
pressure
System leak
Locate and repair leak.
Water in pump
Flush pump with air or dry nitrogen.
Gas ballast plugged
Replace breather vent. Contact Vacuum Technologies.
Solvent in pump
Flush pump with air or dry nitrogen.
Install trap or filter.
Seals worn out
Rebuild pump.
Poor conductance to pump
Replumb with shorter and/or larger diameter tubing.
Hammering noise Pump overheated
Check ventilation to pump.
Check ambient temperature.
Debris in pump
Check intake screen.
Flush pump.
Disassemble pump and inspect.
Pump runs
intermittently
Motor thermal protector is
cycling open and closed.*
Allow the motor to cool.
Identify the cause of the overload.
*
The SH-110 is equipped with an auto-reset thermal motor protector. This protector will automatically shut down the
pump when it detects an overload condition, and will automatically restart the pump when the motor has cooled to
within an acceptable temperature range.