Control Channel Functions
The following control actions must be accomplished with zero time transition or with timing disabled.
Discrete values must be used and not manual controls such as faders or encoders.
To use control channel functions:
Step
1. Select an action to be sent.
Step
2. Set control channel value for desired action (for example, 84 for reset). Hold value for 3
seconds.
Note:
A numerical keypad is required for sending values. An encoder or fader does not allow for a
“snap” value change, which is required to affect the control functions.
Step
3. Set control channel value to zero. (This must occur without any scaling values. Action will
be voided if other values are detected between action value and zero.)
98
250
300
251
310
99
252
310
253
310
254
310
100
255
Follows Cue Data
Table 3-10: Control Channel Functions
Control
Channel
Function
Control Channel Value
% Value
For 3 Secs
or Greater
After
3 Secs
Display On
1
1-4
0
Luminaire Reset
33
81 - 87
0
Lamp Off
66
165 - 171
0
Lamp On
99
249 - 255
0
Table 3-9: Timing Channels Map (Continued)