CURRENT VERSUS VOLTAGE
provides the luminaire’s current draw at specific voltages. Total luminaire current is calculated with the
lamp on and all motors sequencing.
2
InsTallaTIOn & seTuP
POWER AND DATA CABLING REQUIREMENTS
CONNECTING POWER
This fixture requires standard AC power distribution from 100-240 VAC, 50/60 Hz. Current required depends on
the AC supply voltage.
NOTE:
The mating Neutrik® powerCON® True1 connector is supplied; however, you will need to purchase or
construct a cable appropriate for your application.
Depending on the application, the luminaire’s AC input cable may require a dif-
ferent connector. If required, install a new connector meeting your requirements
using the following wire color code reference:
WARNING:
DO NOT connect to three-phase service in countries with 240V power.
DATA IN
DATA
THRU
USB
NETWORK
AC
POWER
THRU
AC
POWER
INPUT
WIRE*
CONNECTION
Green/yellow
aC ground
Blue
aC neutral
Brown
aC line
* International (Harmonized) standard
AC VOLTAGE AT 60HZ
TOTAL CURRENT
100V
7.8a
110V
7.0a
120V
6.4a
130V
5.9a
200V
3.8a
210V
3.6a
220V
3.4a
230V
3.3a
240V
3.2a
TAbLE 1. CURRENT VS. VOLTAGE (550W SOURCE)
CONNECTION
PIN
aC neutral
X
aC line
Y
Ground (earth)
G
X
Y
G
CONNECTION
PIN
Phase 1
X
Phase 2
Y
Ground (earth)
G
For single-phase power at 240 volts RMS:
For three-phase power at 200 volts RMS:
WARNING!
It is the responsibility of the user to ad-
equately protect supply source with a correct size and
type circuit breaker and not overload circuits.
WARNING!
It is not recommended to power any
Vari-Lite luminaire from a dimmer - even in ‘NONDIM’
mode. Dimmer and non-dim modules are not suitable
sources of power because their output modifies the AC
wave form. This may work for a short time, but will even-
tually result in power problems, luminaire misoperation
and/or failure and may void the luminaire’s warranty.