user manuaL
w w w.Va r i - L i t e .co m
VL1600 ProfiLe
16
CAUTION:
Do not push on gobo glass. Press on gobo carrier only.
CAUTION:
Do not touch gobos with bare fingers. Wear cotton gloves or other covering while replacing. To
clean, refer to
care aND maiNteNaNce oN PaGe 35
Step 5. Remove current gobo by carefully pressing on edges of gobo carrier with fingers, pressing gobo to-
ward front end of luminaire (toward lens), and out of wheel.
Step 6. Install new gobo as follows:
a.
Place the gobo holder on a clean, flat work surface with the teeth facing upwards. The gobo is
held in place in the gobo holder by a spring. Taking care to avoid scratching or applying pressure
to the gobo, lever the end of the spring out, remove the spring and then lift the gobo out of the
gobo holder.
b.
Hold the gobo with the dark side facing upwards towards the teeth in the gobo holder. Match up
the alignment marks (arrowed) in the gobo and gobo holder. Lay the new gobo flat in the gobo
holder.
c.
Insert gobo carrier into wheel, ensuring that carrier snaps into place.
Step 7. Rotate desired gobo wheel until required gobo position is accessible.
DMX OPERATION
DMX MAPS
The tables assume a DMX start address of 1. When a different starting address is used, this address becomes
channel 1 function and other functions follow in sequence.
gobo wheel
crossed slot screw
(2 per head cover)
Содержание VL1600 Profile
Страница 1: ...VL1600 Profile user manual...