Reboot Fixture

Select Reboot Fixture, press the ENTER button to confi rm, Are you sure? will show on the display, press the EN-
TER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu 
mode.

Version

Select Version, press the ENTER button to confi rm, Version will show on the display, press the MENU button 
back to exit.

Fixture Hours

Select Fixture Hours, press the ENTER button to confi rm, Fixture Hours will show on the display, press the MENU 
button back to exit.

Crossload (Software)

Select Crossload (Software), press the ENTER button to confi rm, Send will show on the display, press the ENTER 
button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode.

Service

To select Service, press the ENTER button to confi rm. Use the UP/DOWN button to select Service Settings or 
Diagnostics, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 
one minute to exit menu mode.

Service Settings 

Select Service Settings, press the ENTER button to confi rm. Optics Off set will show on the display, press the 
ENTER button to store, Zoom will show on the display. Press the MENU button back to the last menu or let the 
unit idle one minute to exit menu mode.

Diagnostics

To select Diagnostics, press the ENTER button to confi rm. Use the UP/DOWN button to select Fan Check or Led 
Temp, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one 
minute to exit menu mode.

Manual Control

Enter menu mode, select Manual Control, press the ENTER button to confi rm, use the UP/DOWN button to 
select Intensity, Intensity fi ne

All functions. Use the UP/DOWN button to adjust the value from 0 to 255, press 

the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit 
menu mode.

Test 

Enter menu mode, select Test, press the ENTER button to confi rm, use the UP/DOWN button to select All Test, 
Pan/Tilt Test, Test Channel, Encoder Pan or Encoder Tilt.

All Test

Select All Test, press the ENTER button to confi rm, the unit will run all test. Press the MENU button back to the 
last menu or exit menu mode after auto test.

Pan/Tilt Test

Select Pan/Tilt Test, press the ENTER button to confi rm, the unit will run Pan/Tilt test. Press the MENU button 
back to the last menu or exit menu mode after auto test.

Test Channel

To select Test Channel, press the ENTER button to confi rm, the present channel will show on the display, use 
the UP/DOWN button to select channel Intensity …All fuctions, press the ENTER button to confi rm, then use the 
UP/DOWN button to adjust the value, press the ENTER button to store, the fi xture will run as the channel value 
indicates. Press the MENU button back to the last menu or exit menu mode idling one minute.

Encoder Pan

Select Encoder Pan, press the ENTER button to confi rm, displays pan encoder will show on the display. Press 
the MENU button back to the last menu or exit menu mode after auto test.

Encoder Tilt

Select Encoder Tilt, press the ENTER button to confi rm, displays tilt encoder will show on the display. Press the 
MENU button back to the last menu or exit menu mode after auto test.

Содержание EVENTWASH VL800

Страница 1: ...VL800 EVENTWASH USER MANUAL...

Страница 2: ...y be smoke or smells These will disappear after a few minutes of operation Do not place ammable materials near the xture Inspect power cables and replace any damaged cables before each use During oper...

Страница 3: ...functions press the MENU button until the required one is shown on the display Select the func tion by the ENTER button and the display will blink Use the DOWN and UP button to change the mode Once t...

Страница 4: ...Law Curve Linear Law Curve Output Fan Mode Standard Default Studio Whisper Dimming Speed Fast Slow Default White Balance Red Green Blue Reset to default Frequency 900Hz 910Hz 920Hz 930Hz 940Hz 950Hz 9...

Страница 5: ...est All functions Encoder Pan XXXXXXX Displays Pan Encoder Encoder Tilt XXXXXXX Displays Tilt Encoder Address Address DMX address setting To select DMX Address press the ENTER button to con rm Use the...

Страница 6: ...Select Display press the ENTER button to con rm Use the UP DOWN button to select Orienta tion or On Time press the ENTER button to store Select Orientation press the ENTER button to con rm Use the UP...

Страница 7: ...nu or let the unit idle one minute to exit menu mode Manual Control Enter menu mode select Manual Control press the ENTER button to con rm use the UP DOWN button to select Intensity Intensity ne All f...

Страница 8: ...tensity Low 3 Pan High 32767 0 65535 16 bit movement control PAN 540 end to end travel 4 Pan Low 5 Tilt High 32767 0 65535 16 bit Movement control Tilt 220 end to end travel 6 Tilt Low 7 Zoom 128 0 25...

Страница 9: ...CF_18_Congo Blue CF_19_Blue CF_20_Virgin Blue CF_21_Midnight Maya CF_22_Dluble C T Blue CF_23_Slate Blue CF_24_Regal Blue CF_25_Fullt C T Blue CF_26_Steel Blue CF_27_Lighter Blue CF_28_Cyan CF_29_Mar...

Страница 10: ...ure operates at maximum output Default Studio Mode Reduced output with lower fan settings Whisper Mode Redcued output with lower fan settings Reserved Values Fan On Default Fan Auto Reserved Values TA...

Страница 11: ...ntrol of color 39 White Low 4 40 Red High 5 0 0 65535 16 bit control of color 41 Red Low 5 42 Green High 5 0 0 65535 16 bit control of color 43 Green Low 5 44 Blue High 5 0 0 65535 16 bit control of c...

Страница 12: ..._18_Congo Blue CF_19_Blue CF_20_Virgin Blue CF_21_Midnight Maya CF_22_Dluble C T Blue CF_23_Slate Blue CF_24_Regal Blue CF_25_Fullt C T Blue CF_26_Steel Blue CF_27_Lighter Blue CF_28_Cyan CF_29_Marine...

Страница 13: ...Default Reserved Values Reserved Values Dimmer Snap On Fast snaps Dimmer Snap Off Default Smooth Dimming Color Calibration on Color Calibration off Default Standard Mode Fixture operates at maximum o...

Страница 14: ...CF_18_Congo Blue CF_19_Blue CF_20_Virgin Blue CF_21_Midnight Maya CF_22_Dluble C T Blue CF_23_Slate Blue CF_24_Regal Blue CF_25_Fullt C T Blue CF_26_Steel Blue CF_27_Lighter Blue CF_28_Cyan CF_29_Mari...

Страница 15: ...Auto Reserved Values TABLE 5 8 BIT 1 CELL CHANNEL FUNCTION DEFAULT RANGE DESCRIPTION 1 Intensity High 0 0 255 8 Bit control of Dimming 2 Pan High 32767 0 65535 16 Bit Movement control PAN 720 end to...

Страница 16: ...143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 187 188 208 209 229 229 255 Channel OFF RGBW enabled CF_0_Color OFF CF_1_White 10000K CF_2_White 8000K CF_3_White 6500K CF_4_White 5600K CF...

Страница 17: ...es Fixture Shutdown Display Menu ON Display Menu OFF Dimming Curve Linear Dimming Curve S Curve Dimming Curve Square Curve Default Reserved Values Reserved Values Dimmer Snap On Fast snaps Dimmer Snap...

Страница 18: ...ow 3 Red 28 Blue High 3 Green 29 Blue Low 3 Blue 30 White High 3 White 31 White Low 3 Red 32 Red High 4 Green 33 Red Low 4 Blue 34 Green High 4 White 35 Green Low 4 Color Preset 36 Blue High 4 Strobe...

Страница 19: ...uld be terminated to reduce signal errors MAINTENANCE TROUBLESHOOTING Following are a few common problems that may occur during operation The unit does not work light and fan do not turn on Check the...

Страница 20: ...CF_0_Color OFF CF_1_White 10000K CF_2_White 8000K CF_3_White 6500K CF_4_White 5600K CF_5_White 5000K CF_6_White 4500K CF_7_White 4000K CF_8_White 3200 CF_9_White 3000K CF_10_White 2700K CF_11_Moroccan...

Страница 21: ...rve Linear Dimming Curve S Curve Dimming Curve Square Curve Default Reserved Values Reserved Values Dimmer Snap On Dimmer Snap Off Default Reserved Values Reserved Values Standard Mode Studio Mode Fan...

Страница 22: ...NCE TROUBLESHOOTING Following are a few common problems that may occur during operation The unit does not work light and fan do not turn on Check the connection of power and main fuse Measure the main...

Страница 23: ...Road Park Royal London NW10 7QP United Kingdom Tel 44 020 8965 3209 OCEANIA 14H Vega Place Rosedale Auckland 0632 New Zealand Tel 64 9 481 0100 VL800 EVENTWASH User Manual Document no 912400575012UM V...

Отзывы: