Installing Lamp

In the event the lamp was packed separately during shipment, follow the procedure in this section. 

WARNING:  

Disconnect fixture before relamping. 

AVERTISSEMENT: 

Déconnectez le projecteur avant que le changement de lampe.

WARNING:  

Hot Lamp. Luminaire must remain powered on for 5 minutes after dousing lamp. Do not open for 5 minutes after switching 

off. 

AVERTISSEMENT: 

Lampe chaude. Le luminaire doit rester en marche pendant 5 minutes après avoir éteindre la lampe. Ne pas ouvrir 

pendant 5 minutes après la coupure.

WARNING:  

Risk of exposure to excessive ultraviolet radiation. Do not operate without complete lamp enclosure in place or when lens is 

damaged. 

AVERTISSEMENT: 

Risque d’exposition aux rayonnements ultraviolets excessifs. Ne pas faire fonctionner sans le boîtier 

complet de lampe mis en place ou lorsque l’objectif est endommagé.

Note:  

Wear cotton gloves or other covering while installing lamp. Touching lamp glass with bare fingers will leave oil and may cause the 

lamp to explode or reduce lamp life. If touched, use isopropyl alcohol and cotton cloth to thoroughly clean glass portion of lamp.

To install lamp:

Step

1. Ensure power is completely removed from luminaire.

Step

2. Remove lamp from shipping box.

Step

3. Set the luminaire head horizontally.

Step

4. Engage tilt lock to secure luminaire head in position.

Step

5. At back of luminaire, using #2 Phillips screwdriver, remove lamp socket cover by loosening the two quarter-turn captive 

screws. Note: lamp socket cover is connected with a safety tether.

Figure 4:  Lamp Socket Cover Removal

Lamp Socket Cover*

Quarter-Turn Screws

Lamp

Lamp Socket

Note: *lamp socket cover is connected with a safety tether

Содержание 20.9708.0001

Страница 1: ...VARll llllE VL6000 Beam Luminaire QuickStart Guide...

Страница 2: ...ates Institute for Theatre Technology USITT Recommended Practice for DMX512 A Guide for Users and Installers 2nd edition ISBN 9780955703522 USITT Contact Information USITT 315 South Crouse Avenue Suit...

Страница 3: ...nd instructions provided in this manual and any accompanying documentation before installing and operating the products described herein Heed all cautions and warnings during installation and use of t...

Страница 4: ...NTERFERENCE This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Notes de s curit Avant de pro...

Страница 5: ...en s parpillant 4 Se prot ger les yeux pour remplacer la lampe 5 Utiliser des appareils de protection appropri s gants protection des yeux pour manier des lampes endommag es 6 Si la lampe a t touch e...

Страница 6: ...Note Please check with Authorized Vari Lite Dealer for availability on accessories Vari Lite Part No Accessory PCT1BE AC Input Cable Neutrik powerCON True1 with Bare End no connector 1 Meter PC1GTL208...

Страница 7: ...le phase power at 240 volts RMS For three phase power at 200 volts RMS WARNING It is not recommended to power any VARI LITE luminaire from a dimmer even in NONDIM mode Dimmer and non dim modules are n...

Страница 8: ...ion for more information To connect power and data Step 1 Connect data cable from console to first luminaire in chain at DATA IN connector Step 2 If required connect additional data cables from DATA T...

Страница 9: ...sque d exposition aux rayonnements ultraviolets excessifs Ne pas faire fonctionner sans le bo tier complet de lampe mis en place ou lorsque l objectif est endommag Note Wear cotton gloves or other cov...

Страница 10: ...safety tether is completely encapsulated within lamp socket cover Step 10 Disengage tilt lock to allow luminaire head to move freely Step 11 Align lamp as described in Align Lamp For Maximum Beam Irra...

Страница 11: ...tion beam on a white wall at a distance of 10 to 20 feet Step 3 Using console or internal luminaire menu controls focus to a hard edge Be sure that beam size iris is completely opened Step 4 Using thr...

Страница 12: ...intenir une distance de 8 0mm entre le lampe et le couverture arri re comme illustr dans Figure 8 Figure 8 Lamp Adjustment Floor Mounting the Luminaire All luminaires included in this manual are desig...

Страница 13: ...Brackets may be installed in many different orientations as shown in Figure 10 Step 3 While pulling up on locking mechanism release fit keyed holes onto raised mounting buttons at bottom of enclosure...

Страница 14: ...data cables according to procedure given in Connecting Data on page 7 When hanging the luminaire in a side hang position orient the enclosure as shown in Figure 12 Natural convection and the designed...

Страница 15: ...t when the luminaires are side by side Figure 12 Side Hang Orientation If the luminaires are stacked on top of one another in a side hang a 45 enclosure orientation with the fan inlet closest to the f...

Страница 16: ...14 Figure 14 Menu Control LCD Display and Menu System Operation The LCD Display Menu system consists of several categories Use the Menu Buttons to access and make changes to the menu items When the de...

Страница 17: ...system is in battery operation mode Step 3 To exit battery mode press and hold ESC and OK for two seconds Note luminaire will automatically exit this mode after one minute of inactivity Status Bar The...

Страница 18: ...nnel Summary Listing DMX Channel Description DMX Channel Description 1 Intensity 13 Color Wheel 3 2 3 Pan 14 Color Wheel 3 Control 4 5 Tilt 15 Gobo Wheel 1 6 Edge 16 17 Gobo 1 Rot Index 7 Color Wheels...

Страница 19: ...VARI LITE VL6000 BEAM LUMINAIRE QUICKSTART GUIDE 02 9708 0001 27 April 2017 18 Notes...

Страница 20: ...VARI LITE VL6000 BEAM LUMINAIRE QUICKSTART GUIDE 19 27 April 2017 02 9708 0001...

Страница 21: ...VARI LITE VL6000 BEAM LUMINAIRE QUICKSTART GUIDE 02 9708 0001 27 April 2017 20...

Страница 22: ...VARI LITE VL6000 BEAM LUMINAIRE QUICKSTART GUIDE 21 27 April 2017 02 9708 0001...

Страница 23: ...VARI LITE VL6000 BEAM LUMINAIRE QUICKSTART GUIDE 02 9708 0001 27 April 2017 22...

Страница 24: ......

Отзывы: