C
HAPTER
3. M
AINTENANCE
P
ROCEDURES
3-13
02.9631.0010
CONFIDENTIAL
15 Jan 98
To perform self test:
Step 1.
At console, change page to Luminaire Test Status.
Step 2.
At console, type test number in cue keypad window (or console
channel select panel) and observe test. Refer to Test Code
Description paragraph in this procedure for specific test
numbers.
Note: Leading zeros for tests are assumed by console software and need
not be entered. Example: Test 1 is assumed to be 001.
3.1.2.6
Reading Error Codes
While luminaires may be tested simultaneously, error codes must be read
sequentially, one luminaire at a time.
To locate and read error codes:
Step 1.
At console, go to Luminaire Test window (not to be confused
with Luminaire Test Stat window).
Step 2.
Press [ERR CHANS]. Channels with test errors will be
displayed on cue key pad (for mini-Artisan 2 and mini-
Artisan Plus consoles) or console channel select panel (for
Artisan control console).
Step 3.
At console, switch to Luminaire Test Status window.
Step 4.
At console cue keypad or the channel select panel, enter
channel for luminaire to be analyzed.
Step 5.
Press and release [CHANNEL] button. Error code for selected
channel will display in console board control window.
Step 6.
Press and release [NEXT ERR] button to scroll to next error
for same luminaire.
Step 7.
To observe errors for additional channels, deselect current
channel and repeat steps 4 thru 6.
Note: Most Significant Digit (MSD) of error code corresponds to Least
Significant Digit (LSD) of test number. For example, any error code
beginning with 6 would indicate an error associated with color wheel #1
(Test X06 is the test for color wheel #1, as indicated in the Test Code
Description paragraph).