3.1.2.3
Downloadable Test Setup
To prepare luminaires for downloadable test:
Step 1.
Connect luminaire to console utilizing all appropriate equipment
and apply power. Refer to Series 200® System Installation and
Checkout Manual (02.9622.0010).
Step 2.
At console board control window, scroll to Board Utilities and
select [DIAGS] Option .
Step 3.
Under Diagnostic Services there are four options. Select
[DNLD TEST].
Note: Luminaire Test window has two pages. Pressing the Page button
scrolls back and forth between the two pages.
Step 4.
At the console, select channels for all luminaires to be tested.
Step 5.
Press and hold the [ENABLE] button and press [RESET TST].
To test multiple luminaires simultaneously, press [RESET TST]
twice.
Selected luminaires will calibrate, then head and yoke will go to limit stop
and remain in that position.
3.1.2.4
Verifying Software Downloaded
To verify test has been downloaded to appropriate luminaires:
Step 1.
At console, press [TEST CHANNELS].
Step 2.
At cue key pad (for mini-Artisan 2 and mini-Artisan Plus
consoles) or console channel select panel (for Artisan control
console), verify channels selected for test.
3.1.2.5 Perform
Test
Once test software has been downloaded, test may be run from console or
from individual luminaire by adjusting luminaire thumbwheel. To return
luminaire to console control, thumbwheel setting must be reset to original
address. All selected luminaires may be tested simultaneously, or individual
luminaires may be selected at the console for individual testing. With
software loaded in luminaire, luminaire may be disconnected from console
and repowered via cheater cable for isolated remote test and/or
troubleshooting.