2.4 Intensité (courant alternatif)
plage
résolution
précision
600µA
0.1µA
+/- (1.2% + 3)
6000µA
1µA
+/- (1.2% + 3)
60mA
0.01mA
+/- (1.2% + 3)
600mA
0.1mA
+/- (1.2% + 3)
6A
0.001A
+/- (1.5% + 5)
10A
0.01A
+/- (1.5% + 5)
Protection :
Plage mA : fusible F1
ɸ6x32mm F 600mA H 600V
Plage 10A : fusible F2
ɸ6x25mm, F 10 A H 600V
2.5 Résistance
Plage
résolution
précision
6
00Ω
0.1Ω
+/- (1.0% + 2)
6
kΩ
0.001kΩ
+/- (0.8% + 2)
6
0kΩ
0.01kΩ
+/- (0.8% + 2)
6
00kΩ
0.1kΩ
+/- (0.8% + 2)
6
0MΩ
0.01MΩ
+/- (2.0% + 5)
Protection :
600Vrms
2.6 Capacitance
Plage
résolution
précision
9.999nF
0.001nF
+/- (4.0% + 10)
99.99nF
0.01nF
+/- (4.0% + 5)
999.9nF
0.1nF
+/- (4.0% + 5)
9.999µF
0.001µF
+/- (4.0% + 5)
99.99µF
0.01µF
+/- (4.0% + 5)
999.9µF
0.1µF
+/- (4.0% + 5)
9.999mF
0.001mF
+/- 10%
Protection :
600V-PTC
Test
capacitance ≤ 200nF, adapté au mode REL
2.7 Température
Plage
résolution
précision
°C
-40 ~
1000°C
-40~40°C
1°C
+/- 4°C
>40~500°C
+/- (1.0% + 4)
>500~1000°C
+/- (2.0% + 4)
°F
-40 ~
1832°F
-40~104°F
1°F
+/- 5°F
>104~932°F
+/- (1.5% + 5)
>932~1832°F
+/- (2.5% + 5)
Protection :
600V
K-type thermocouple type K est seulement possible pour les
températures inférieures à 250°C/482°F
2.4 AC current
range
resolution
accuracy
600µA
0.1µA
+/- (1.2% + 3)
6000µA
1µA
+/- (1.2% + 3)
60mA
0.01mA
+/- (1.2% + 3)
600mA
0.1mA
+/- (1.2% + 3)
6A
0.001A
+/- (1.5% + 5)
10A
0.01A
+/- (1.5% + 5)
Protection :
mA range : fuse F1
ɸ6x32mm F 600mA H 600V
10A range : fuse F2
ɸ6x25mm, F 10 A H 600V
2.5 Resistance
range
resolution
accuracy
6
00Ω
0.1Ω
+/- (1.0% + 2)
6
kΩ
0.001kΩ
+/- (0.8% + 2)
6
0kΩ
0.01kΩ
+/- (0.8% + 2)
6
00kΩ
0.1kΩ
+/- (0.8% + 2)
6
0MΩ
0.01MΩ
+/- (2.0% + 5)
Protection :
600Vrms
2.6 Capacitance
range
resolution
accuracy
9.999nF
0.001nF
+/- (4.0% + 10)
99.99nF
0.01nF
+/- (4.0% + 5)
999.9nF
0.1nF
+/- (4.0% + 5)
9.999µF
0.001µF
+/- (4.0% + 5)
99.99µF
0.01µF
+/- (4.0% + 5)
999.9µF
0.1µF
+/- (4.0% + 5)
9.999mF
0.001mF
+/- 10%
Protection :
600V-PTC
Test capacitance ≤ 200nF, adapt REL mode
2.7 Temperature
range
resolution
accuracy
°C
-40 ~
1000°C
-40~40°C
1°C
+/- 4°C
>40~500°C
+/- (1.0% + 4)
>500~1000°C
+/- (2.0% + 4)
°F
-40 ~
1832°F
-40~104°F
1°F
+/- 5°F
>104~932°F
+/- (1.5% + 5)
>932~1832°F
+/- (2.5% + 5)
Protection :
600V
K-type thermocouple is only applicable for temperature less than
250°C/482°F
3. MAINTENANCE
Avant de remplacer la batterie, débranchez les pointes de test
et éteignez le multimètre. Dévisser les vis du capot de la
batterie. Spécification de la batterie : AAA 1.5V x2.
Pour remplacer les fusibles, dévissez les vis à l’arrière de
l’appareil. Spécification des fusibles :
F1
ɸ6x32mm, F 600mA H 600V
F2
ɸ6x25mm, F 10 A H 600V
3. MAINTENANCE
Before replacing the battery, remove the test leads and switch off
the multimeter. Take off the screw on the battery cover. Battery
specifications : AAA 1.5V x2.
To replace fuse, take off the screws on the back of the
multimeter. Fuse specifications :
F1
ɸ6x32mm, F 600mA H 600V
F2 ɸ6x25mm, F 10 A H 600V