VLC5501 Vapormatic Immobiliser Installation Manual
15 of 21
4. Keypad not accepting new user codes, 1
long beep
Check power supply, go to 2
Check correct procedure for adding codes. (see
page 12)
Switch ignition off, switch ignition on, try again with
correct master code, confirm with #
Are you hearing a beep on every digit entry
Re-set to factory default by using Master override
card 8 digit unique number (please refer to the PIN
code card section in the User manual)
5. Immobiliser not working, 30 amp relays
not in circuit, engine starts with out
entering PIN code
Check in-line fuses to immobiliser blockers
Is the Keypad Override Disc within a 5 metre range
or on person
Check all wiring for good connections
Check chassis earth
Test blockers, normally closed with no power, open
with power
6. Immobiliser not working, 30 amp relays
in circuit, engine starts with out entering
PIN code
Check relays & correct wiring to relay terminals
Check chassis earth to relays
Check power supply from blockers
7. System not working
Check vehicle power supply
Check immobilisers in-line fuses
Check for correct wiring connections to vehicle
Check all connection for good contact
Check for good chassis earth
Check the serial numbers match on the immobiliser
blockers (Sticker on casing), Keypad mounting plate
(Sticker on mounting plate) and Keypad Override
Disc (Sticker on PCB board)
Check for correct code, enter factory reset 8 digit
code (please refer to the PIN code card section in
the User manual)
Complete installation tests as per manual