P/N VT-108732-US, Manual revision: C

 

 

 

  

5-2 

Repair

 

 

 

 

C

USTOMER  SERVICE

 

 

Services 

Clinical  training

 

The local Vante  representative will provide staff training upon delivery of  the 

equipment and should be contacted to organize further instruction if needed. 

 

Repair service

 

Vante maintains a worldwide network of company-trained service 

representatives responsible for responding to technical needs concerning 

equipment. If service beyond the routine maintenance and cleaning described in 

this manual is required, Vante should be  contacted to provide specific 

instruction. 
In the continental U.S., Vante may be reached  by  calling  (877)  565-5557. 

 

Product return guidelines

 

If, for any reason, merchandise must be returned to the company, the customer 

should contact the local Vante representative to arrange for repairs or returns 

using procedures to  ensure proper handling and subsequent analysis. No 

returns will be accepted  without advanced authorization. 

 

Warning: Vante products must be properly cleaned and packaged prior  to 

their return. It remains an important responsibility of the customer to reduce 

potential health hazards by being aware of the risks involved in the shipping, 

handling and testing of this material. Units returned to Vante for repair  are 

subject to biohazard charges if any component is contaminated with blood or 

blood products.

 

Содержание SEBRA 2605

Страница 1: ...operation manual VT 108732 US Model 2605 Segmenting Head VANTE INC IGNITING INNOVATION...

Страница 2: ...Printed in USA Copyright 2002 2010 2017 Vante...

Страница 3: ...66 Toll free 1 877 565 5557 Disclaimer This manual is intended as a guide to provide the operator with necessary instructions on the proper use and maintenance of certain Vante Corporation products Th...

Страница 4: ......

Страница 5: ...2 SPECIFICATIONS 2 3 Environment 2 3 Mechanical and Weight 2 3 Chapter 3 Sealing Head Operation SETUP 3 1 RECOMMENDED TUBING 3 1 SEALING PROCEDURE 3 2 SEAL SPACING 3 5 Chapter 4 Cleaning the Sealing H...

Страница 6: ...ronic Equipment 7 1 RF Effects In Potentially Explosive Atmospheres 7 1 List of Figures Figure 2 1 Model 2605 Segmenting Head 2 2 Figure 3 1 Correct Technique for Holding the Tubing 3 2 Figure 3 2 Inc...

Страница 7: ......

Страница 8: ...tant and or critical information Note provides useful information regarding a procedure or operating technique when using Vante material Caution advises the operator against initiating an action or cr...

Страница 9: ...rocessing facilities and transfusion centers Tubing or bags utilized in the collection and handling of blood and blood products is typically made from thermoplastic vinyl namely polyvinylchloride PVC...

Страница 10: ...e 2 1 Model 2605 Segmenting Head Table 2 1 Sealing Head Component Functions Component Function Ground Jaw Compresses tubing while RF is applied to form seal RF Jaw Delivers RF energy to tubing to form...

Страница 11: ...or tubing exterior may affect actual perfor mance Users are advised that when temperature and humidity conditions seem less than what might be considered comfortable for humans it is best to slow the...

Страница 12: ...P N VT 108732 US Manual revision C Sealing Head Description 2 4...

Страница 13: ...ion ranges of PVC tubing The Sealer is designed to seal blood bag transfer sets and intravenous tubing small or medium size with typical outside diameter of 0 148 1 18 inch 3 8 4 6 mm and wall thickne...

Страница 14: ...econd After the seal is formed the sealing jaw will retract to its original position Warning Do NOT pull the tubing or bag through the sealing region Under no circumstances should the tubing be pulled...

Страница 15: ...d experience these problems reduce the rate of sealing as necessary or allow for periods of rest for the Sealing Head Caution Never trigger the jaws when non RF reactive materials are in the sealing r...

Страница 16: ...e an opening in the tubing which will subject the blood or plasma to non sterile conditions and the user to potentially hazardous fluids In addition the Sealing Head may become damaged by arcing due t...

Страница 17: ...that progress along an open ended length of tubing may be spaced as desired but inch 1 cm is the recommended minimum Multiple seals in close proximity are not required nor are they recommended when us...

Страница 18: ......

Страница 19: ...the RF jaw tube assembly and void the warranty Figure 4 1 Incorrect Cleaning Technique Note Other than periodic cleaning the Sealing Head is designed to be mainte nance free and to withstand substanti...

Страница 20: ...is carefully understood and observed Note The illustrations in this section show the splash guard removed for clarity However to perform a topical cleaning it is not necessary to remove the splash gua...

Страница 21: ...If the splash guard was removed for topical cleaning be sure to follow the cleaning procedure in Splash Guard Replacement on page 4 5 before reinstalling a new splash guard If the above procedure doe...

Страница 22: ...ead components See Chapter 6 1 Disconnect the Sealing Head from the Power Source by removing the RF power cable and seven pin connector from the Power Source Warning Failure to separate the Sealing He...

Страница 23: ...emoving Adhesive Residue 4 Dry the Sealing Head completely 5 Remove the paper backing from adhesive on the new splash guard 6 Align and attach the new splash guard See Figure 4 6 Attachment of New Spl...

Страница 24: ...nd or Segmenting Head case with the damp tissue until clean Make sure the surfaces are completely dry before putting back into service Caution Do not apply fluids directly to the Sealing Head case and...

Страница 25: ...ot properly aligned CallVante Bad seals or intermittent seals occur Sealing Head power source combination may not give optimumperformance Check to see if another Sealing Head connected to the power so...

Страница 26: ...continental U S Vante may be reached by calling 877 565 5557 Product return guidelines If for any reason merchandise must be returned to the company the customer should contact the local Vante repres...

Страница 27: ...wareness Assign individuals responsibility for the maintenance of clean up supplies and equipment spill handling leadership and training and record keeping Signif icant blood spill occurrences should...

Страница 28: ...h solution or by autoclaving if applicable A contaminated Sealing Head RF jaw tube assembly head should be cleaned with alcohol in accordance with the procedures in this document while wearing disposa...

Страница 29: ...ante RF instruments interfere with the function of modern cardiac pacemakers Electrical Safety Vante RF devices meet or exceed appropriate electrical safety standards and pose no electrical shock haza...

Страница 30: ......

Страница 31: ......

Страница 32: ...Vante Inc 3480 E Britannia Dr Suite 120 Tucson AZ 85706 USA www vante com 2002 2010 2017Vante Inc...