![Vantage Hearth VSGF36NRC Скачать руководство пользователя страница 30](http://html2.mh-extra.com/html/vantage-hearth/vsgf36nrc/vsgf36nrc_owners-manual-and-installation-manual_3460430030.webp)
www.fmiproducts.com
121082-01K
30
SPECIFICATIONS
Figure 47 - Remote Control Wiring Diagram
Black Connectors
Receiver
To Thermopile
White
Red
Model VSGF36NRC
• Rating (Variable): 33,000/21,500 Btu/Hr
• Type Gas: Natural Gas
• Ignition: Electronic
• Pressure Manifold: 3.5" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 10.5" W.C., Minimum* 5" W.C.
• Shipping Weight:
120 lbs.
* For input adjustment
Model VSGF36PRC
• Rating (Variable): 33,000/21,500 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Pressure Manifold: 7.9" W.C.
• Inlet Gas Pressure (in. of water):
Maximum 13" W.C. Minimum* 11" W.C.
• Shipping Weight:
120 lbs.
* For input adjustment
TECHNICAL SERVICE
You may have further questions about installa
-
tion, operation or troubleshooting. If so, contact
FMI PRODUCTS, LLC at 1-866-328-4537.
When calling, please have your model and
serial numbers of your firebox ready.
You can also visit FMI PRODUCTS, LLC’s
web site at
www.fmiproducts.com
.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low for
propane/LP unit
You may feel your gas pressure is too low. If
so, contact your local gas supplier.
WIRING DIAGRAM
Note: For proper operation of remote control, wires from thermopile to control receiver must
be connected exactly as shown.