background image

www.fmiproducts.com

121082-01K

17

INSTALLATION

Continued

PRESSURE TESTING FIREPLACE GAS 

CONNECTIONS

1.  Open  equipment  shutoff  valve  (see 

Figure 18, page 16).

2.  Open main gas valve located on or near 

gas meter for natural gas or open pro-

pane/LP supply tank valve.

3.  Make sure control knob of fireplace is in 

the OFF position.

4.  Check  all  joints  from  equipment  shutoff 

valve to gas control valve (see Figures 

19 or 20, page 16). Apply noncorrosive 

leak detection fluid to all joints. Bubbles 

forming show a leak.

5.  Correct all leaks at once.

6.  Light fireplace (see 

Operation

, page 20.) 

Check all other internal joints for leaks.

7.  Turn off fireplace (see 

To Turn Off Gas to 

Appliance

, page 21.

INSTALLING BATTERIES IN 

REMOTE CONTROL AND RECEIVER

 WARNING: Make sure your 

selector switch is in OFF posi

-

tion before installing or chang

-

ing batteries in your hand-held 

remote or receiver. 

Hand-Held Remote Control

The hand-held remote control uses 3 AAA 

batteries (not included). 

To install batteries:
1.  Remove battery housing cover from back 

of hand-held remote (see Figure 21).

2.  Install or replace batteries.

3.  Replace battery housing cover.

When batteries are installed, the "little house" 

icon with current room temperature will be dis-

played (see Figure 22). This icon will always 

show in the control window as long as the 

batteries have power.

Figure 22 - Remote Display

+

+

-

+

-

-

AAA
AAA
AAA

Figure 21 - Battery Install Hand-Held 

Remote Control

Battery Housing 

Cover

Figure 23 - Battery Install Remote 

Control Receiver

Battery Housing 

Cover

Cover Plate

Screws

Receiver

Remote Receiver

The remote receiver uses 4 AA batteries (not 

included). 

To install or replace batteries:

1.  Open lower louver to gain access to re-

ceiver.

2.  Remove screws from cover place.
3.  Remove battery housing cover.
4.   Install or replace batteries.
5.  Replace battery housing cover.
6.  Replace cover plate.

Содержание VSGF36NRC

Страница 1: ...ot touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier ca...

Страница 2: ...t a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion an...

Страница 3: ...ct con tainsand orgenerateschemicals known to the state of California to cause cancer or birth defects or other reproductive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying...

Страница 4: ...ing off see Troubleshooting page 26 10 Do not run fireplace where flammable liquids or vapors are used or stored under dusty conditions 11 Do not use this fireplace to cook food or burn paper or other...

Страница 5: ...sembly and fireplace 4 Check heater for any shipping damage If heater is damaged call FMI PRODUCTS LLC at 1 866 328 4537 for replacement parts before returning to dealer PRODUCT FEATURES OPERATION Thi...

Страница 6: ...ou install your firebox Before installation consider the following 1 Where firebox will be located Allow for wall and ceiling clearances see Installa tion Clearances page 10 2 Everything needed to com...

Страница 7: ...nusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you must provi...

Страница 8: ...t vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors Example Gas water heater __________ Btu Hr Vent free fireplace _________ Btu Hr Total _________ Btu H...

Страница 9: ...vide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the attic will activate the power vent Figure 5 Ventilation Air from Outdoors Figu...

Страница 10: ...e Call dealer where you bought fireplace for proper type fireplace WARNING This appliance is equipped for either natural gas or propane LP gas but not both Gas type is indicated on the rat ingplate Fi...

Страница 11: ...rim accessories are available see Accessories page 31 Brass trim will ex tend past sides of firebox approximately 1 2 This will cover rough edges of wall opening If installing a mantel above firebox y...

Страница 12: ...for attaching trim 7 Install and properly test gas log heater Follow installation instructions included with the vent free gas log heater that is being installed IMPORTANT When finishing your firebox...

Страница 13: ...You can secure base to floor using wood screws Countersink screw heads and putty over 4 Route flexible gas line through access hole in hearth base 5 Center cabinet mantel on hearth base see Figure 12...

Страница 14: ...e optional shutoff valve from your dealer Minimum inlet pressure for purpose of input adjustment Figure 15 Gas Connection Sediment Trap Equipment Shutoff Valve With 1 8 NPT Tap 3 Minimum Cap Pipe Tee...

Страница 15: ...gure 16 Removing Log Base Assembly From Fireplace Figure 17 Attaching Flexible Gas Lines Together Flexible Gas Line from Fireplace Gas Regulator To Fireplace Gas Regulator Equipment Shutoff Valve Prov...

Страница 16: ...ed on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Corre...

Страница 17: ...g ing batteries in your hand held remote or receiver Hand Held Remote Control The hand held remote control uses 3 AAA batteries not included To install batteries 1 Remove battery housing cover from ba...

Страница 18: ...vertical and not leaning in toward burner where the flame will touch the log 3 Position front right log against right side of grate prongs see Figure 24 4 Position front left log against left side of...

Страница 19: ...cal cable through strain relief and handy box see Figure 26 Tighten screws on strain relief 3 Connect electrical cable to duplex outlet Match wire colors to those on duplex out let Be sure to connect...

Страница 20: ...Button Blower Control Knob OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal inj...

Страница 21: ...isintheOFFposition whenyouareawayfromhomefor long periods of time Heater will comeonautomaticallywithselec tor switch in the ON position ON REMOTE OFF PRG Figure 30 Remote Selector Switch in ON Positi...

Страница 22: ...temperature in either Fahrenheit or Celsius With remote control off press THERMOSTAT button and MODE button at the same time This will toggle the display from F to C Figure 34 Remote Control Display...

Страница 23: ...mperature bulb graphic on display see Figure 37 Use UP DOWN arrow button to set desired room temperature Control system will cycle fireplace on or off to maintain selected temperature To activate this...

Страница 24: ...Appliance page 21 see Troubleshooting page 26 Note The correct pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color MAIN BURNER Period...

Страница 25: ...reater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions on the can If you don t follo...

Страница 26: ...ny metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace ignitor 5 Replace pilot assembly 6 Replace pilot assembly 7 Install new alkaline battery in electronic ignitor Verify bat te...

Страница 27: ...ore 6 Replace pilot assembly 7 Replace control valve 8 Wait one minute for safety interlock system to reset Repeat ignition operation Burner does not light after ODS pilot is lit 1 Inlet gas pressure...

Страница 28: ...any 3 Observeminimuminstallation clearances see page 10 4 Clean burners see Cleaning and Maintenance page 25 or replace burner orifice s White powder residue forming within burner box or on adja cent...

Страница 29: ...Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilation 2 Contact local natural or propane LP gas company 3 CleanODS pilot seeCleaning and Maintenance page 25 Gas...

Страница 30: ...hipping Weight 120 lbs For input adjustment TECHNICAL SERVICE You may have further questions about installa tion operation or troubleshooting If so contact FMI PRODUCTS LLC at 1 866 328 4537 When call...

Страница 31: ...shed Traditional Design Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealers of this product If they can t sup...

Страница 32: ...MODELS VSGF36PRC VSGF36NRC 23 17 19 15 12 12 14 11 16 24 25 18 31 20 NG Only 21 NG Only 33 34 38 27 14 13 32 26 LPG 7 22 28 6 2 4 3 NG Only 35 36 5 1 37 9 10 8 23 30 29 AAA Battery Negative UP Install...

Страница 33: ...241 03 Valve Bracket 1 16 111440 04 Gas Valve 1 111440 03 Gas Valve 1 17 103782 01 Valve Bracket 1 18 098265 02 Male Elbow 1 19 099387 09 Pilot Tube 1 099387 12 Pilot Tube 1 20 099918 02 Pilot Regulat...

Страница 34: ...www fmiproducts com 121082 01K 34 PARTS MODELS VSGF36PRC AND VSGF36NRC 1 4 8 7 6 27 9 10 28 11 12 22 18 29 25 26 20 17 21 19 16 15 13 5 2 3 14 23 24...

Страница 35: ...20280 Top Spacer 4 17 Fireplace Surround 1 18 107128 01 Gas Conduit 2 19 115408 01 Receptacle Plate 1 20 21171 Gas Knock Out Cover 4 21 103771 01 Strain Relief 1 22 115402 01 Steel Receptacle Box 1 2...

Страница 36: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...