  WARNING:  Any  change  to 

this  heater  or  its  controls  can 

be dangerous.

 WARNING: Do not allow fans 

to blow directly into the fireplace. 

Avoid any drafts that alter burner 

flame patterns. Ceiling fans can 

create  drafts  that  alter  burner 

flame  patterns.  Altered  burner 

patterns can cause sooting.

 WARNING: Do not use a blow

-

er insert, heat exchanger insert, 

or other accessory not approved 

for use with this fireplace. 

Due  to  high  temperatures,  the 

appliance should be located out 

of traffic and away from furniture 

and draperies.

Do not place clothing or other 

flammable  material  on  or  near 

the appliance. Never place any 

objects in the fireplace.

Fireplace  front  and  screen  be

-

come very hot when running fire

-

place. Keep children and adults 

away from hot surfaces to avoid 

burns or clothing ignition. Fire

-

place will remain hot for a time 

after shutdown. Allow surfaces 

to cool before touching.

Carefully supervise young chil

-

dren when they are in the room 

with fireplace.

You must operate this fireplace 

with  the  fireplace  screen  and 

hood  in  place.  Make  sure  fire

-

place screen is in place before 

running fireplace.

saFeTy

Continued

Keep  the  appliance  area  clear 

and free from combustible ma

-

terials, gasoline, and other flam

-

mable vapors and liquids.

1.  This appliance is only for use with type of 

gas indicated on rating plate. This appli-

ance is not convertible for use with other 

gases.

2.  Do not place propane/LP supply tank(s) 

inside any structure. Locate propane/LP 
supply  tank(s)  outdoors  (propane/LP 
only).

3.  If you smell gas

• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a  neighbor’s  phone.  Follow  the  gas 

supplier’s instructions 

• if  you  cannot  reach  your  gas  supplier, 

call the fire department

4.  This fireplace shall not be installed in a 

bedroom or bathroom.

5.  Do not use this fireplace as a wood-burn

-

ing fireplace. Use only the logs provided 
with the fireplace. 

6.  Do not add extra logs or ornaments such 

as pine cones, vermiculite, or rock wool. 

Using these added items can cause soot-
ing. Do not add lava rock around base. 
Rock and debris could fall into the control 

area of fireplace.

7.  This fireplace is designed to be smoke

-

less. If logs ever appear to smoke, turn 
off  fireplace  and  call  a  qualified  service 

person. 

 

Note: During initial operation, slight smok-

ing could occur due to log curing and fire

-

place burning manufacturing residues. 

8.  To prevent the creation of soot, follow the 

instructions in 

Cleaning and Maintenance

page 23.

9.  Before using furniture polish, wax, carpet 

cleaner, or similar products, turn heater 
off. If heated, the vapors from these prod

-

ucts may create a white powder residue 
within burner box or on adjacent walls or 

furniture.

Содержание VMH26TNC

Страница 1: ...switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department...

Страница 2: ...ot convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING Thisproductcon tainsand orgenerateschemicals known to the state of Califo...

Страница 3: ...of gas indicated on rating plate This appli ance is not convertible for use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors propa...

Страница 4: ...ld cause pilot outage 16 Do not operate fireplace if any log is broken Do not operate fireplace if a log is chipped dime sized or larger 17 To prevent performance problems do not use propane LP fuel t...

Страница 5: ...ware packet 4 Check fireplace for any shipping damage If heater is damaged call FMI PRODUCTS LLC at 1 866 328 4537 for replacement parts before returning to dealer WARNING Always have branch support a...

Страница 6: ...ut and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter yo...

Страница 7: ...ft ceiling height 2560 cu ft volume of space If additional ventilation to adjoining room is supplied with grills or openings add the volume of these rooms to the total volume of the space 30 000 26 0...

Страница 8: ...R COMBUSTION AND VENTILATION Continued Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling...

Страница 9: ...codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection ground joint union sediment trap tee joint pipe wrench A shutoff valve with 1 8 NPT tap is an ac ceptable alter...

Страница 10: ...and depth of the fireplace CAUTION If you install the fireplace in a home garage fireplace pilot and burner must be at least 18 above floor locatefireplacewheremoving vehicle will not hit it For conv...

Страница 11: ...make all electrical connections 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after the equipment shutoff valve The flex...

Страница 12: ...r is installed install a properly grounded 120 volt three prong electrical outlet at fireplace location if an outlet is not there If possible locate outlet so cabinet mantel will cover it when install...

Страница 13: ...r Bracket Mounting Holes Figure 13 Installing Fireplace into Mantel Assembly 4 Slide one end of adjusting plate shim in slot on mitered edge of top trim see Figure 14 5 Slide other end of adjusting pl...

Страница 14: ...casing see Figure 17 Plug fan kit into 120 Volt grounded power supply and test operation Installing Blower Assembly CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors c...

Страница 15: ...ound in hardware kit into the hole left by supply cord strain relief 4 A licensed electrician must follow the wir ing diagram to connect incoming electri cal supply to fan kit wiring harness see Figur...

Страница 16: ...ocal codes Use pipe of 1 2 or greater diameter to allow proper gas volume to fireplace If pipe is too small undue loss of volume will occur Propane LP Supply Tank External Regulator Figure 21 External...

Страница 17: ...e Branch Support Screen Screen Shipping Screw Shoulder Screw Flexible Gas Line CONNECTING Equipment shutoff valve to heater control Installation Items Needed Phillips screwdriver sealant resistant to...

Страница 18: ...re Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equip ment shutoff valve from gas supply pip...

Страница 19: ...fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the...

Страница 20: ...ireplace screen in place Make sure fire place screen is installed before running fireplace NOTICE Duringinitialoperation of new fireplace burning logs will give off a paper burning smell Orange flame...

Страница 21: ...uction installation location room size open air temperatures etc Frequent use of your fireplace will let you determine your own comfort levels MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 unde...

Страница 22: ...n in Figure 34 turn fireplace off see To Turn Off Gas to Appliance page 21 see Troubleshooting page 24 Figure 33 Correct Burner Flame Pattern Figure 34 Incorrect Burner Flame Pattern Inspecting Burner...

Страница 23: ...lean Inspect these areas of fireplace before each use Have fireplace inspected yearly by a qualified service person Fireplace may need more frequent cleaning due to excessive lint from carpeting beddi...

Страница 24: ...osition 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Free ignitor cable if pinched by any metal or t...

Страница 25: ...lock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 Hand tighten until snug then tighten 1 4 turn more 6 A Contact local propane LP or natural gas company B Clean OD...

Страница 26: ...let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 12 4 Clean...

Страница 27: ...ly clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion ventilation...

Страница 28: ...der Warranty Contact authorized dealers of this product If they can t supply original replacement part s call FMI PRODUCTS LLC at 1 866 328 4537 When calling have ready your name your address model an...

Страница 29: ...shed Traditional Design W26GO Oak Finished Georgian Design For all models Mantel features clean classic lines Available in a stained oak or unfinished hardwood ready to stain or paint Complete assembl...

Страница 30: ...cts com 113111 01K 30 Parts Models vmh26tpC Shown and vmh26tnC 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 17 19 6 22 31 21 41 42 16 15 18 24 28 34 25 27 20 4 35 12 24 12 1 14 25 14 40 3 37 26...

Страница 31: ...rew 2 19 Outer Shell Base 1 20 102649 02 Branch Support 1 21 099415 09 Gas Regulator 1 099415 10 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23 101381 01 Valve Cover and Piezo 1 24 099387 11 Pilo...

Страница 32: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...