background image

www.fmiproducts.com

113111-01

9

InsTallaTIon

IMPORTANT: 

Vent-free fireplaces add mois

-

ture  to  the  air. Although  this  is  beneficial, 
installing fireplace in rooms without enough 
ventilation air may cause mildew to form from 

too much moisture. See 

Air for Combustion 

and Ventilation, 

page 6.

Note: Your VANTAGE HEARTH fireplace is 

designed to be used in zero clearance instal-
lations. Wall or framing material can be placed 
directly against any exterior surface of your 

fireplace, except where standoff spacers are 

integrally  attached.  If  standoff  spacers  are 
attached  to  your  fireplace,  these  spacers 

can be placed directly against wall or fram

-

ing materials.

Use the dimensions shown for rough openings 

to create the easiest installation (see 

Built-In 

Fireplace Installation

, page 10).

CHECK GAS TYPE

Use only the correct type of gas (natural or 
propane/LP).  If  your  gas  supply  is  not  the 

correct  gas  type,  do  not  install  heater.  Call 
dealer  where  you  bought  heater  for  proper 

type heater.

 WARNING: This appliance is 

equipped for either natural gas 

or propane/LP gas but not both. 

Gas type is indicated on the rat

-

ing plate. Field conversion is not 

permitted.

INSTALLATION ITEMS

Before  installing  fireplace,  make  sure  you 
have the items listed below.
•  external regulator - propane/LP only (sup

-

plied by installer)

•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  test gauge connection*
•  ground joint union
•  sediment trap
•  tee joint
•  pipe wrench
*  A shutoff valve with 1/8" NPT tap is an ac

-

ceptable alternative to test gauge connection. 

Purchase the optional equipment shutoff valve 

from your dealer. 

Note: If desired, purchase a four-sided trim 
kit for built-in installations. See Accessories, 
page 29.

NOTICE: This heater is intended 

for  use  as  supplemental  heat. 

Use this heater along with your 

primary heating system. Do not 

install  this  heater  as  your  pri

-

mary heat source. If you have a 

central heating system, you may 

run system’s circulating blower 

while using heater. This will help 

circulate the heat throughout the 

house. In the event of a power 

outage, you can use this heater 

as your primary heat source.

 WARNING: A qualified ser

-

vice  person  must  install  fire

-

place. Follow all local codes.

 WARNING: Never install the 

fireplace

•  in a bedroom or a bathroom 

•  in a recreational vehicle

•  where  curtains,  furniture, 

clothing,  or  other  flammable 

objects are less than 36" from 

the front, top, or sides of the 

fireplace

•  as a fireplace insert

•  in high traffic areas

•  in windy or drafty areas

 CAUTION: This fireplace cre

-

ates  warm  air  currents.  These 

currents move heat to wall sur-

faces next to fireplace. Installing 

fireplace  next  to  vinyl  or  cloth 

wall  coverings  or  operating 

fireplace where impurities (such 

as,  but  not  limited  to,  tobacco 

smoke, aromatic candles, clean-

ing fluids, oil or kerosene lamps, 

etc.) in the air exist, may discolor 

walls or cause odors.

Содержание VMH26TNC

Страница 1: ...switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department...

Страница 2: ...ot convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING Thisproductcon tainsand orgenerateschemicals known to the state of Califo...

Страница 3: ...of gas indicated on rating plate This appli ance is not convertible for use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors propa...

Страница 4: ...ld cause pilot outage 16 Do not operate fireplace if any log is broken Do not operate fireplace if a log is chipped dime sized or larger 17 To prevent performance problems do not use propane LP fuel t...

Страница 5: ...ware packet 4 Check fireplace for any shipping damage If heater is damaged call FMI PRODUCTS LLC at 1 866 328 4537 for replacement parts before returning to dealer WARNING Always have branch support a...

Страница 6: ...ut and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter yo...

Страница 7: ...ft ceiling height 2560 cu ft volume of space If additional ventilation to adjoining room is supplied with grills or openings add the volume of these rooms to the total volume of the space 30 000 26 0...

Страница 8: ...R COMBUSTION AND VENTILATION Continued Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 of the ceiling...

Страница 9: ...codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection ground joint union sediment trap tee joint pipe wrench A shutoff valve with 1 8 NPT tap is an ac ceptable alter...

Страница 10: ...and depth of the fireplace CAUTION If you install the fireplace in a home garage fireplace pilot and burner must be at least 18 above floor locatefireplacewheremoving vehicle will not hit it For conv...

Страница 11: ...make all electrical connections 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after the equipment shutoff valve The flex...

Страница 12: ...r is installed install a properly grounded 120 volt three prong electrical outlet at fireplace location if an outlet is not there If possible locate outlet so cabinet mantel will cover it when install...

Страница 13: ...r Bracket Mounting Holes Figure 13 Installing Fireplace into Mantel Assembly 4 Slide one end of adjusting plate shim in slot on mitered edge of top trim see Figure 14 5 Slide other end of adjusting pl...

Страница 14: ...casing see Figure 17 Plug fan kit into 120 Volt grounded power supply and test operation Installing Blower Assembly CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors c...

Страница 15: ...ound in hardware kit into the hole left by supply cord strain relief 4 A licensed electrician must follow the wir ing diagram to connect incoming electri cal supply to fan kit wiring harness see Figur...

Страница 16: ...ocal codes Use pipe of 1 2 or greater diameter to allow proper gas volume to fireplace If pipe is too small undue loss of volume will occur Propane LP Supply Tank External Regulator Figure 21 External...

Страница 17: ...e Branch Support Screen Screen Shipping Screw Shoulder Screw Flexible Gas Line CONNECTING Equipment shutoff valve to heater control Installation Items Needed Phillips screwdriver sealant resistant to...

Страница 18: ...re Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equip ment shutoff valve from gas supply pip...

Страница 19: ...fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the...

Страница 20: ...ireplace screen in place Make sure fire place screen is installed before running fireplace NOTICE Duringinitialoperation of new fireplace burning logs will give off a paper burning smell Orange flame...

Страница 21: ...uction installation location room size open air temperatures etc Frequent use of your fireplace will let you determine your own comfort levels MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 unde...

Страница 22: ...n in Figure 34 turn fireplace off see To Turn Off Gas to Appliance page 21 see Troubleshooting page 24 Figure 33 Correct Burner Flame Pattern Figure 34 Incorrect Burner Flame Pattern Inspecting Burner...

Страница 23: ...lean Inspect these areas of fireplace before each use Have fireplace inspected yearly by a qualified service person Fireplace may need more frequent cleaning due to excessive lint from carpeting beddi...

Страница 24: ...osition 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Free ignitor cable if pinched by any metal or t...

Страница 25: ...lock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 Hand tighten until snug then tighten 1 4 turn more 6 A Contact local propane LP or natural gas company B Clean OD...

Страница 26: ...let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 12 4 Clean...

Страница 27: ...ly clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion ventilation...

Страница 28: ...der Warranty Contact authorized dealers of this product If they can t supply original replacement part s call FMI PRODUCTS LLC at 1 866 328 4537 When calling have ready your name your address model an...

Страница 29: ...shed Traditional Design W26GO Oak Finished Georgian Design For all models Mantel features clean classic lines Available in a stained oak or unfinished hardwood ready to stain or paint Complete assembl...

Страница 30: ...cts com 113111 01K 30 Parts Models vmh26tpC Shown and vmh26tnC 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 17 19 6 22 31 21 41 42 16 15 18 24 28 34 25 27 20 4 35 12 24 12 1 14 25 14 40 3 37 26...

Страница 31: ...rew 2 19 Outer Shell Base 1 20 102649 02 Branch Support 1 21 099415 09 Gas Regulator 1 099415 10 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23 101381 01 Valve Cover and Piezo 1 24 099387 11 Pilo...

Страница 32: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...

Отзывы: