RadioLink ScenePoint DR Station — MODEL: RDR<XXXX> 

page 3 of 4 

ScenePoint Wiring Examples 
 
 
 
 
 
 
Motorized Blind 

 Always disconnect 

power before wiring the 
station and shade motor. In 
this application the Interlock 
Switch is set to 

active

 or 

Interlocked. Connect load 1 
to the open relay of the blind 
motor and load 2 to the 
close relay, or vice-versa. 
Typically, neutrals are all tied 
together at the station box. 
Custom program desired 
operation in Design Center. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
Fan and Light 

 

 Always disconnect 

power before wiring the 
station and station loads. In 
this application the Interlock 
Switch is set to inactive or 
the non-interlocked position. 
Connect relay load 1 to the 
light and relay load 2 to the 
fan, or vice-versa. Typically, 
neutrals are all tied together 
at the station box. Custom 
program desired operation in 
Design Center. 
 
NOTE: The light may not be 
dimmed in this application. 
 
 
 
 
 

 
 
 
 