RadioLink ScenePoint DR Station — MODEL: RDR<XXXX>
page 3 of 4
ScenePoint Wiring Examples
Motorized Blind
Always disconnect
power before wiring the
station and shade motor. In
this application the Interlock
Switch is set to
active
or
Interlocked. Connect load 1
to the open relay of the blind
motor and load 2 to the
close relay, or vice-versa.
Typically, neutrals are all tied
together at the station box.
Custom program desired
operation in Design Center.
Fan and Light
Always disconnect
power before wiring the
station and station loads. In
this application the Interlock
Switch is set to inactive or
the non-interlocked position.
Connect relay load 1 to the
light and relay load 2 to the
fan, or vice-versa. Typically,
neutrals are all tied together
at the station box. Custom
program desired operation in
Design Center.
NOTE: The light may not be
dimmed in this application.