Gasline Installation:
This gas appliance should be installed by a qualified
installer in accordance with local building codes and with
current CAN/CGA - B149.1 or .2 installation codes for Gas
Burning appliances and equipment in Canada.
Installations in the USA must conform to the local codes
or in the absence of local codes to the current version of
National Fuel Gas Code, ANSI Z223.1/NFPA 54. Electrical
Installations must conform to the local codes or, in the ab-
sence of local codes, to the current version of the National
Electrical Code, ANSI/NFPA 70. See Appendix C for
installation within the State of Massachusetts..
1.
The gas pipeline can be brought into the fireplace
through the left or right side of the appliance. Knockouts
are provided at either location to allow for the gas pipe
installation, and testing of any gas connection.
2.
The gas control inlet is 3/8” NPT.
3.
When using copper or flex connector, use only approved
fittings. Always provide a union so that gas line can be
easily disconnected for burner or fan servicing. See gas
specification for pressure details and ratings.
4.
When a vertical section of gas pipe is required for the
installation, a condensation trap is needed. See CAN/CGA-
B149.1 or .2 for code details.
5.
For natural gas, a minimum of 3/8” iron pipe or copper
tubing need be used for supply from the gas meter. Con-
sult with the local gas utility if any questions arise concern-
ing pipe sizes.
6.
1/8” NPT plugged tappings are accessible for test gauge
connection both on the inlet and outlet of the gas valve.
7.
Turn the gas supply ON and check for leaks. DO NOT USE
OPEN FLAME FOR THIS PURPOSE. Use an approved leak
testing solution.
8.
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 PSIG (3.5 KPa).
9.
The appliance must be isolated from the gas supply
piping system by closing its individual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 PSIG (3.5 KPa).
Section 7:
Installing the Gasline
Figure 25.
Gas Line / Valve Installation.
Copper
Rigid pipe
SIT control
valve
Gas Specifications and Ratings:
Model: VZB28BN and VRI28BN
NG - Millivolt & IPI; 18,000 BTU/h
NG - IPI & MV; 18,000 BTU/h
Gas Inlet
Gas Supply Min. 5.5 WC
Max. 14.7 WC
Manifold Pressure; 3.5 WC
Orifice Size, #47dms.
WARNING
A Qualified Electrician must connect electrical wiring
to junction outlet for built-in installation.
AVERTISSEMENT
Un électricien qualifié doit raccorder le câblage
électrique à la sortie de la jonction pour l'installation
intégrée.
WARNING
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper or danger-
ous operation. Verify proper operation after servicing.
AVERTISSEMENT
Identifiez tous les fils avant de les débrancher lors
des contrôles. Les erreurs de câblage peuvent
provoquer un mauvais fonctionnement ou dangereux.
Vérifier le bon fonctionnement après l'entretien.
Part. No.
VZB28BN-Man-101817-A
VZB28BN Gas Fireplace
VANOX Fireplace Inc.
Page 18
Содержание LYRA VZB28BN
Страница 20: ...Part No VZB28BN Man 101817 A VZB28BN Gas Fireplace VANOX Fireplace Inc Page 20 SIT Millivolts Valve...
Страница 21: ...SIT IPI Valve Part No VZB28BN Man 101817 A VZB28BN Gas Fireplace VANOX Fireplace Inc Page 21...
Страница 22: ...Part No VZB28BN Man 101817 A VZB28BN Gas Fireplace VANOX Fireplace Inc Page 22...
Страница 30: ...Vanox Fireplaces Inc Port Coquitlam BC VANOX Fireplace Inc P r i n t e d i n C a n a d a...