INCORPORATED
®
Installation
ITC-Series
Inverter
Page 7
Owner‟s Manual 10/7/05
(Vanner Part # D011339) must be installed in it‟s place to insure that debris does not enter the unit through
the opening and to maintain proper airflow through the unit.
Specifications
Model
ITC12-2100
ITC12-3200
ITC24-3600
SP00172
AC OUTPUT
Voltage (RMS)
120 VAC
Frequency
60 Hz ± 0.5%
AC Waveform
Sine Wave
Total Harmonic Distortion (THD)
Less than 4.0% @ full power
Power Factor Allowed
-1 to 1
Continuous Output Rating @ 25ºC
Phase to Neutral
2100 watts
(17.5 amps)
3200 watts
(26.7 amps)
3600 watts
(30.0 amps)
Surge Capacity @ 25ºC (3 sec.)
6400 watts
DC INPUT:
Operating Range (12 Volt Nominal)
10.5 to 17 Volts
21.0 to 31 Volts
No Load, Inverter ON
4 amps
3 amps
No Load, Inverter OFF
0.30 amps
0.30 amps
Full power
208 amps
350 amps
195 amps
INVERTER EFFICIENCY @ Nom.
200 watts
77%
77%
500 watts
88%
84%
700 watts
88%
87%
1000 watts
88%
89%
1500 watts
86%
89%
2000 watts
84%
89%
2500 watts
NA
81%
88%
3000 watts
NA
78%
87%
3200 watts
NA
77%
87%
3600 watts
NA
NA
86%
AC INPUT
Voltage
120 Volts nominal
Frequency
60 Hz ± 12.5% (52.5 to 67.5)
AC TRANSFER SWITCH
Power Rating
30 amps @ 120 VAC
Transfer Time
Less than
40
milliseconds
BATTERY CHARGER
Charger Output Current maximum
60, 80 or 110 amps
AC Input Current maximum
30 amps
(0.88PF @ rated output)
SYSTEM
Ambient Operating Temperature
-40 to+40 C (-40 to+104 F)
Cooling Exhaust Fan
Thermostatically controlled
Mounting
Shelf or suspended
Dimensions Bottom mount position)
8 1/4”H x 18 7/16”W x 13 5/8”D
Weight
66 pounds
Component Identification/Location
The Figures below show the location of the various components of the ITC system.