background image

Vanner Power Group

20-1000TUL INVERTER—OWNER'S MANUAL

N O T E

N O T E

N O T E

N O T E

N O T E

Air enters by the
fan at the rear of
the unit, and exits
through the sides
of the unit. For
maximum unit
performance, avoid
recirculating the
same hot air
through the unit.

W

W

W

W

W A R N I N G

A R N I N G

A R N I N G

A R N I N G

A R N I N G

Battery input
cables must be
connected to the
battery with
proper polarity
to avoid
damaging the
inverter.

Section 2: Installing the 20-1000TUL

Unpacking the Inverter

Inspect the shipping container and equipment for loose or damaged parts.

`

If any damage is found, immediately notify the freight carrier.

Installing the Inverter

Step 1: Turn the inverter OFF/disconnect power to the wiring harness.

Make sure power to the vehicle wiring harness is disconnected. Verify
that the inverter is turned OFF by checking that the ON-OFF/RESET
Inverter Switch is in the OFF-RESET position.
(The button should NOT be pushed in.)

Step 2: Select a location for the unit.

An ideal installation location has the following characteristics:
• Close to the battery (within six feet using #2 AWG wire)
• Protected from the weather
• Well ventilated

Step 3: Route DC input cables.

Route the negative and positive DC input cables from the inverter (through
the quick connector) to the battery. If required, protect cables where they
contact hard, sharp edges.

Step 4: Install in-line fuse.

Install an in-line Bussman ANN 125 or equivalent fuse (Vanner p/n 03640-
fuse and 03637-fuse holder) in the red, positive DC input cable between the
battery and inverter, within 18 in. of the battery or DC wiring bus system.

Step 5: Connect Bonding Lug.

Use a AWG #8 or larger copper conductor to connect the chassis bonding lug
to the vehicle chassis and/or earth ground.

Step 6: Connect the inverter to the battery.

Connect the black, negative DC input cable from the quick connector to the
battery negative (-) terminal. This battery negative terminal is usually where
the battery negative connects to the engine block or frame.

Connect the red, positive DC input cable from the quick connector to the
fuse of the battery positive (+) terminal. This battery terminal is usually
connected to the DC electrical system at the load side of the Battery
Disconnect Switch.

— 4 —

DC Cable Length

DC Cable Length

DC Cable Length

DC Cable Length

DC Cable Length

S i z e

S i z e

S i z e

S i z e

S i z e

M a x i m u m

M a x i m u m

M a x i m u m

M a x i m u m

M a x i m u m

2 A W G

1 2 f t .

1/O AWG

20 ft.

Содержание 20-1000TUL

Страница 1: ...Model 20 1000TUL AC Power Inverter System OWNER S MANUAL OM A96751 REV A...

Страница 2: ...he 20 1000TUL Inverter 9 Section 7 Troubleshooting 10 Section 8 GFCI Test Record 11 Warranty 12 List of Figures Figure 1 System Diagram 2 Figure 2 IFM1 Module Remote Wiring 7 Icon Legend W W W W Warni...

Страница 3: ...lent performance and reliability for your emergency vehicle With minimum maintenance and care you can expect years of trouble free service from your Vanner product The 20 1000TUL is a 12 VDC to 120 VA...

Страница 4: ...tly reducing the current draw from the battery until a demand is made on its output Continuous output of 120 VAC resumes when a load greater than 5 Watts is applied The load demand feature can be disa...

Страница 5: ...ry y y y y OFF 0 017 Amps Typical Load Demand waiting 0 09 Amps Typical Full ON at No Load 0 7 Amps Typical Full ON with Load Approx AC Load Watts 10 or AC Load Amps x 12 Frequency 60 Hz 0 1 Output Wa...

Страница 6: ...rom the weather Well ventilated Step 3 Route DC input cables Route the negative and positive DC input cables from the inverter through the quick connector to the battery If required protect cables whe...

Страница 7: ...ht Action Light Action Description Description Description Description Description Solid Red Inverter is On and the battery is almost too low to operate the inverter Blinking Red The inverter is Off T...

Страница 8: ...ce Cable length to the inverter Additionally the unit should not be installed with pin connections facing upward Step 2 Connect the Inverter to the Interface Module Install the 2 ft interface cable by...

Страница 9: ...re to install the Inverter Remote Status Display Panel Step 1 Select a location for the panel Identify the desired location for the inverter panel Step 2 Identify wires for installation Identify the g...

Страница 10: ...is operational Single Blink Green Light Inverter is not being used Shore power is applied to load Inverter will activate when shore power is unavailable Double Blink Green Light Inverter is on in the...

Страница 11: ...the ON position When powered by the AC power the ON lamp flashes indicating that the inverter is standing by Step 5 Verify Power Apply an AC load such as a shop light or drill The AC load is run dire...

Страница 12: ...ower is OFF SYMPT SYMPT SYMPT SYMPT SYMPTOM OM OM OM OM ON lamp fully illuminates AC load does not run SOL SOL SOL SOL SOLUTION UTION UTION UTION UTION Check and reset circuit breaker Verify AC load a...

Страница 13: ...L J U L J U L J U LY Y Y Y Y A U G A U G A U G A U G A U G S E P T S E P T S E P T S E P T S E P T O C T O C T O C T O C T O C T N O V N O V N O V N O V N O V D E C D E C D E C D E C D E C Y E A R Y...

Страница 14: ...ts product for any undertaking representation or warranty made by any dealers or distributors selling its products beyond herein expressed 5 Vanner does not assume responsibility for incidental or con...

Страница 15: ......

Страница 16: ...nner Power Group ower Group ower Group ower Group ower Group 4282 Reynolds Drive Hilliard Ohio 43026 Tel 614 771 2718 Fax 614 771 4904 Specifications Subject to Change Copyright 1996 Vanner Weldon Inc...

Отзывы: