Section 5: Inverter Status Panel Operation
Two LEDs on the front of the Remote Status Display Panel indicate the status of the
inverter. The status indicated by the LED displays is directly related to the status
indicated by the LEDs on the front of the inverter.
Inverter LED
Inverter LED
Inverter LED
Inverter LED
Inverter LED
Light Action
Light Action
Light Action
Light Action
Light Action
Description
Description
Description
Description
Description
Steady Green Light
Inverter is operational.
Single Blink-Green Light
Inverter is not being used. Shore power is applied to load. Inverter will
activate when shore power is
unavailable.
Double Blink-Green Light
Inverter is on in the Load Demand mode and is waiting for AC load to be
turned ON.
Inverter F
Inverter F
Inverter F
Inverter F
Inverter Fault LED
ault LED
ault LED
ault LED
ault LED
Light Action
Light Action
Light Action
Light Action
Light Action
Description
Description
Description
Description
Description
Red Light
Unit shutdown
*
— Check the inverter's front panel LEDs for reason of
shutdown: Low Battery, Overload,
or Overtemp.
*
Refer to the Troubleshooting section of this manual for fault diagnostic information.