background image

STONEVAC MILLSYNC

120V

140 N. Brandon

  

  

P.O. Box 74, Fallbrook, CA 92088

  

  

1-800-VANIMAN (826-4626)

SV-MS-04/18 Page 2

MAINTENANCE

1. 

Cleaning the Filter

 - When a noticeable drop in suction occurs in the unit, it is time to clean the filter.  

To use the self-cleaning feature of the StoneVac, push and hold the Power switch in the “CLEAN” 

position for several seconds.  Optimum cleaning takes place in within 5 seconds.  For best results, wait 

an additional 10-15 seconds with the Power switch in the 

“OFF”

 or center position, this allows the dust 

cleaned from the filter to fall into the dust bin before turning the unit on again.

2. 

Emptying the Dust Bin

 - Depending on usage, the unit will need to be emptied at different intervals.  

To check the level of dust in the bin, open the door and observe the dust level.  To empty, open the door 

and slide the bin from the unit.  Pull the edges of the bag together to close the bag for disposal.  Replace 

the bag with a Vaniman replacement and carefully slide the dust bin back into the unit. Replacement 

bag re-order number 

P/N 97002 

(pack of 12).

3. 

Servicing or Replacing the Filter Cartridge

 - Regularly check the filter to make sure it is secure and 

properly seated against the filter mounting/sealing plate.  Periodically, the filter cartridge will become 

worn or clogged beyond the use of the “CLEAN” feature.  In cases when dust collector usage is heavy, 

changing interval may be as frequent as 3-6 months.  To replace the filter, follow the instructions above 

to remove and empty the dust bin.  With the dust bin removed, reach underneath the Filter Cartridge 

and unscrew the filter retaining nut.  Remove the nut and washers and pull the filter downward then 

forward out of the unit.  Replace the filter with a new filter cartridge then reverse removal instructions 

for proper installation. Filter Cartridge re-order 

P/N 97001

.   

NOTE: 

Be sure to replace the rubber washer 

FIRST

 and the metal washer 

SECOND

.  Securely  fasten    

 

    the filter retaining nut. Improper installation may cause dust to pass into the air. 

4.  

Electrical Protection

 - The StoneVac is protected by a circuit breaker.  If the unit is plugged in and 

does not operate, check to see if the circuit breaker was activated by inspecting it on the back of the unit 

where the power cord enters the unit.  If the circuit breaker was activated, push the button in the center 

to reset it.  If the unit still does not operate, contact your dealer or call the factory at 1-800-VANIMAN for 

technical assistance.
5.  

Thermal Protection

 - The brushless motor is thermally protected is virtually maintenance free.  However, 

if improper ventilation is not provided to the unit, it may overheat and shut down.  Allow the unit to cool 

fully, correct the ventilation problem and restart the unit.