STONEVAC MILLSYNC
120V
140 N. Brandon
P.O. Box 74, Fallbrook, CA 92088
1-800-VANIMAN (826-4626)
SV-MS-04/18 Page 2
MAINTENANCE
1.
Cleaning the Filter
- When a noticeable drop in suction occurs in the unit, it is time to clean the filter.
To use the self-cleaning feature of the StoneVac, push and hold the Power switch in the “CLEAN”
position for several seconds. Optimum cleaning takes place in within 5 seconds. For best results, wait
an additional 10-15 seconds with the Power switch in the
“OFF”
or center position, this allows the dust
cleaned from the filter to fall into the dust bin before turning the unit on again.
2.
Emptying the Dust Bin
- Depending on usage, the unit will need to be emptied at different intervals.
To check the level of dust in the bin, open the door and observe the dust level. To empty, open the door
and slide the bin from the unit. Pull the edges of the bag together to close the bag for disposal. Replace
the bag with a Vaniman replacement and carefully slide the dust bin back into the unit. Replacement
bag re-order number
P/N 97002
(pack of 12).
3.
Servicing or Replacing the Filter Cartridge
- Regularly check the filter to make sure it is secure and
properly seated against the filter mounting/sealing plate. Periodically, the filter cartridge will become
worn or clogged beyond the use of the “CLEAN” feature. In cases when dust collector usage is heavy,
changing interval may be as frequent as 3-6 months. To replace the filter, follow the instructions above
to remove and empty the dust bin. With the dust bin removed, reach underneath the Filter Cartridge
and unscrew the filter retaining nut. Remove the nut and washers and pull the filter downward then
forward out of the unit. Replace the filter with a new filter cartridge then reverse removal instructions
for proper installation. Filter Cartridge re-order
P/N 97001
.
NOTE:
Be sure to replace the rubber washer
FIRST
and the metal washer
SECOND
. Securely fasten
the filter retaining nut. Improper installation may cause dust to pass into the air.
4.
Electrical Protection
- The StoneVac is protected by a circuit breaker. If the unit is plugged in and
does not operate, check to see if the circuit breaker was activated by inspecting it on the back of the unit
where the power cord enters the unit. If the circuit breaker was activated, push the button in the center
to reset it. If the unit still does not operate, contact your dealer or call the factory at 1-800-VANIMAN for
technical assistance.
5.
Thermal Protection
- The brushless motor is thermally protected is virtually maintenance free. However,
if improper ventilation is not provided to the unit, it may overheat and shut down. Allow the unit to cool
fully, correct the ventilation problem and restart the unit.