Vanguard VMH26TPB Скачать руководство пользователя страница 4

111043-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

4

ASSEMBLY

 WARNING: Always have branch support and

screen in place before operating fireplace. This pre-
vents excessive temperatures on fireplace surfaces.

 WARNING: Failure to position the parts in accor-

dance with these diagrams or failure to use only parts
specifically approved with this fireplace may result in
property damage or personal injury.

Figure 3 - Assembling Fireplace

ASSEMBLING FIREPLACE

Tools Required:

• Phillips screwdriver

• 5/16" hex wrench

• slotted screwdriver

Installing Log

1.

Lift screen up and pull out to remove.

2.

Cut two plastic straps to remove the log from the firebox cavity.

3.

An optional blower is available. See Accessories, page 26. In-
stall optional blower now. Follow installation instructions pro-
vided with blower.

4.

Remove log packaging material and discard packaging. Gently
place log set on burner support (see Figure 3). The log should
fit flat against top of burner support and log locator tabs fit
into the slots under the log. Do not allow log to contact flame.
If flame contacts log, soot will be created.

5.

Reattach screen by placing the notches in the screen frame
over the shoulder screws and pushing down.

PRODUCT FEATURES

SAFETY PILOT

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot is a required feature for vent-free
room fireplaces. The ODS/pilot shuts off the fireplace if there is not
enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system requires no matches,
batteries, or other sources to light fireplace.

THERMOSTATIC HEAT CONTROL

This fireplace has a thermostat sensing bulb and a control valve. The
thermostat will automatically modulate the heat output to maintain
a consistent room temperature. This results in greater fireplace
comfort. This can also result in lower gas bills.

IMPORTANT:

THIS PACKAGE CONTAINS A

FIREPLACE HOOD. UNWRAP

CARTON AND REMOVE HOOD

BEFORE DISCARDING

PROTECTIVE PACKAGING.

1

2

UNPACKING

1.

Remove log box and fireplace from carton. The hood is not
attached. 

IMPORTANT:

 The fireplace hood is inside the card-

board protective end wrap on the left side of fireplace (as
viewed from front). A decal is on the outside of the cardboard
end wrap stating hood is enclosed (see Figure 2).

2.

Remove hood from cardboard protective end wrap as shown
in Figure 2.

3.

Remove all protective packaging applied to fireplace for shipment.

4.

Make sure your fireplace includes one hardware packet.

5.

Check fireplace for any shipping damage. If fireplace is dam-
aged, promptly inform dealer where you bought fireplace.

Figure 2 - Removing Fireplace Hood

Hood

Cardboard
Protective
Fireplace
End Wrap

Hood Enclosed
Decal

Log

Screen

Burner Support with
Log Locator Tabs

Branch
Support

Shoulder
Screw

PRODUCT FEATURES
UNPACKING
ASSEMBLY

Assembling Fireplace

Содержание VMH26TPB

Страница 1: ...for correct installa tion and operational procedures For as sistance or additional information con sult a qualified installer service agency or the gas supplier This appliance may be installed in an a...

Страница 2: ...ng fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting Due to high temperatures the appliance should be located out of traffic and away from furniture and...

Страница 3: ...n adjacent walls or furniture 10 This fireplace needs fresh air ventilation to run properly This fireplace has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fireplace if...

Страница 4: ...nsing ODS safetyshutoffsystem TheODS pilotisarequiredfeatureforvent free room fireplaces The ODS pilot shuts off the fireplace if there is not enough fresh air PIEZO IGNITION SYSTEM This fireplace has...

Страница 5: ...fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is defined as construction where a wall...

Страница 6: ...soropen ings add the volume of these rooms to the total volume of the space 2 Multiply the space volume by 20 to determine the maximum Btu Hr the space can support __________ volume of space x 20 Maxi...

Страница 7: ...e National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air i...

Страница 8: ...unting Clearances As Viewed From Front of Fireplace Shown Built In the Wall INSTALLATION Continued IMPORTANT Vent free fireplaces add moisture to the air Although this is beneficial installing firepla...

Страница 9: ...ning to use blower locate fireplace near an electrical outlet 267 8 267 8 3 4 Off The Floor Minimum 10 1 2 Figure 9 Rough Opening for Installing in Wall WARNING If pre wiring do not connect wiring to...

Страница 10: ...replace and set aside 2 Place fireplace on wood base 3 Place mantel around fireplace base assembly 4 Assemble brass trim kit See Assembling Brass Trim page 11 13 16 19 21 2 1 2 6 8 10 Note All vertica...

Страница 11: ...s louvers 1 3 4 Screw Wood Base INSTALLATION Continued Shoulder Screws Assembled Brass Trim Hole for 3 wood screw for attaching fireplace to mantel Hole for 3 wood screw for attaching fireplace to woo...

Страница 12: ...the assembly down see Figure 17 2 Using short Phillips screwdriver remove the screw under the center of the branch support Rotate valve cover shield clock wise and slide out IMPORTANT Do not remove sh...

Страница 13: ...valve cover shield The other hole is for a strain relief clamp not supplied to secure incoming electrical supply 2 Follow steps 2 through 6 in Installing BlowerAssembly page 12 Also remove black wire...

Страница 14: ...onry drill at least 1 deep 2 Fold floor anchor as shown in Figure 22 3 Insert floor anchor wings first into hole Tap anchor flush to floor 4 Insert mounting screws through base and into floor anchors...

Страница 15: ...e Figure 25 Carefully lift up branch support and remove from fireplace see Figure 25 3 Route flexible gas line included from fireplace control to equip mentshutoffvalvethroughsideorrearaccessholesinou...

Страница 16: ...leak detection fluid to gas joints Bubbles form ing show a leak 4 Correct all leaks at once Pressure Testing Fireplace Gas Connections 1 Open equipment shutoff valve see Figure 27 2 Open main gas valv...

Страница 17: ...ire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service techni cian or...

Страница 18: ...ING PROCEDURE OPERATING FIREPLACE Continued OPERATING BLOWER OFF ON Auto Off On Switch This blower has three settings ON OFF and AUTO In the ON position the blower will operate constantly In the OFF p...

Страница 19: ...with a mild soap and water mixture Wipe the cabinet to remove dust INSPECTING BURNER Burner Flame Pattern CLEANING AND MAINTENANCE Cleaning Burner Injector Holder and Pilot Air Inlet Hole Cabinet WAR...

Страница 20: ...mocouple damaged 8 Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ignitor...

Страница 21: ...rough 10 4 Clean burner see Cleaning and Mainte nance page 19 or replace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products OBSERVED PROBLEM Burner do...

Страница 22: ...1 Gas leak SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventil...

Страница 23: ...DESA Heating Products Techni cal Service Department at 1 866 672 6040 for referral information When calling DESA Heating Products have ready your name your address model and serial numbers of your fi...

Страница 24: ...satech com 24 ILLUSTRATED PARTS BREAKDOWN MODELS VMH26TPB Shown AND VMH26TNB 12 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 17 19 6 22 31 21 41 42 16 15 18 24 28 34 25 27 20 4 35 12 24 12 1 14...

Страница 25: ...se 1 20 102649 01CK 102649 01CK Branch Support 1 21 099415 09 099415 10 Gas Regulator 1 22 102875 01 102875 01 Regulator Bracket 1 23 101381 01 101381 01 Valve Cover and Piezo 1 24 099387 11 099387 11...

Страница 26: ...Equipment shutoff valve with 1 8 NPT tap THERMOSTATICALLY CONTROLLED BLOWER KIT GA3450T Provides better heat distribution Makes fireplace more efficient Automatically turns off and on as needed BRASS...

Страница 27: ...ed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 4...

Страница 28: ...111043 01B For more information visit www desatech com For more information visit www desatech com 28 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 29: ...________________________________________________________ _______________________________________________________________________________________________ _______________________________________________...

Страница 30: ...as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing...

Отзывы: