Vanguard VMH26TPB Скачать руководство пользователя страница 15

111043-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

15

15

We recommend that you install a sediment trap in supply line as
shown in Figure 24. Locate sediment trap where it is within reach for
cleaning. Install in piping system between fuel supply and heater.
Locate sediment trap where trapped matter is not likely to freeze. A
sediment trap traps moisture and contaminants. This keeps them
from going into fireplace controls. If sediment trap is not installed
or is installed wrong, fireplace may not run properly.

Figure 24 - Gas Connection

INSTALLATION

Continued

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

PROPANE/LP
From External Regulator
(11" W.C. to 14" W.C.
Pressure)

NATURAL
From Gas Meter (5" W.C.
to 10.5" W.C. Pressure)

3" Minimum

Pipe

Cap

Tee

Nipple

Joint

Sediment Trap

* Purchase the optional CSA design-certified equipment shutoff
valve from your dealer. See Accessories, page 26.

CONNECTING EQUIPMENT SHUTOFF VALVE
TO HEATER CONTROL

Installation Items Needed

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not provided)

1.

Remove fireplace screen. Remove two screws that hold fire-
place screen in place for shipping. These screws are located
near top of screen. Discard screws. Lift fireplace screen up
and pull out to remove.

2.

Remove screws that attach branch support to fireplace (see
Figure 25). Carefully lift up branch support and remove from
fireplace (see Figure 25).

3.

Route flexible gas line included from fireplace control to equip-
ment shutoff valve through side or rear access holes in outer casing.

NOTICE: Most building codes do not permit con-
cealed gas connections. A flexible gas line is pro-
vided to allow accessibility from the fireplace (see
Figure 25). The flexible gas supply line connection to
the equipment shutoff valve should be accessible.

4.

Apply pipe joint sealant lightly to male threads of gas connec-
tor attached to flexible gas line/equipment shutoff valve (see
Figure 26).

5.

Check all gas connections for leaks. See Checking Gas Con-
nections,
 page 16.

6.

Replace branch support back into fireplace. Feed flexible gas
line into fireplace base area while replacing branch support.
Make sure the entire flexible gas line is in fireplace base area.
Reattach branch support to fireplace with screws removed in
step 2.

 CAUTION: Avoid damage to regulator. Hold gas

regulator with wrench when connecting it to gas
piping and/or fittings.

Figure 25 - Removing Log Base Assembly From Fireplace

Figure 26 - Attaching Flexible Gas Line to Equipment Shutoff
Valve

Branch
Support

Screen

Screen
Shipping
Screw

Shoulder
Screw

Flexible
Gas Line

Flexible Gas Line from
Fireplace Gas Regulator
Provided with Fireplace

To Fireplace
Gas Regulator

Equipment Shutoff Valve
Provided by Installer

PROPANE/LP
To External
Regulator

NATURAL
To Gas Supply

INSTALLATION

Connecting to Gas Supply (Cont.)

Connecting Equipment Shutoff Valve to Heater Control

Содержание VMH26TPB

Страница 1: ...for correct installa tion and operational procedures For as sistance or additional information con sult a qualified installer service agency or the gas supplier This appliance may be installed in an a...

Страница 2: ...ng fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting Due to high temperatures the appliance should be located out of traffic and away from furniture and...

Страница 3: ...n adjacent walls or furniture 10 This fireplace needs fresh air ventilation to run properly This fireplace has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fireplace if...

Страница 4: ...nsing ODS safetyshutoffsystem TheODS pilotisarequiredfeatureforvent free room fireplaces The ODS pilot shuts off the fireplace if there is not enough fresh air PIEZO IGNITION SYSTEM This fireplace has...

Страница 5: ...fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is defined as construction where a wall...

Страница 6: ...soropen ings add the volume of these rooms to the total volume of the space 2 Multiply the space volume by 20 to determine the maximum Btu Hr the space can support __________ volume of space x 20 Maxi...

Страница 7: ...e National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air i...

Страница 8: ...unting Clearances As Viewed From Front of Fireplace Shown Built In the Wall INSTALLATION Continued IMPORTANT Vent free fireplaces add moisture to the air Although this is beneficial installing firepla...

Страница 9: ...ning to use blower locate fireplace near an electrical outlet 267 8 267 8 3 4 Off The Floor Minimum 10 1 2 Figure 9 Rough Opening for Installing in Wall WARNING If pre wiring do not connect wiring to...

Страница 10: ...replace and set aside 2 Place fireplace on wood base 3 Place mantel around fireplace base assembly 4 Assemble brass trim kit See Assembling Brass Trim page 11 13 16 19 21 2 1 2 6 8 10 Note All vertica...

Страница 11: ...s louvers 1 3 4 Screw Wood Base INSTALLATION Continued Shoulder Screws Assembled Brass Trim Hole for 3 wood screw for attaching fireplace to mantel Hole for 3 wood screw for attaching fireplace to woo...

Страница 12: ...the assembly down see Figure 17 2 Using short Phillips screwdriver remove the screw under the center of the branch support Rotate valve cover shield clock wise and slide out IMPORTANT Do not remove sh...

Страница 13: ...valve cover shield The other hole is for a strain relief clamp not supplied to secure incoming electrical supply 2 Follow steps 2 through 6 in Installing BlowerAssembly page 12 Also remove black wire...

Страница 14: ...onry drill at least 1 deep 2 Fold floor anchor as shown in Figure 22 3 Insert floor anchor wings first into hole Tap anchor flush to floor 4 Insert mounting screws through base and into floor anchors...

Страница 15: ...e Figure 25 Carefully lift up branch support and remove from fireplace see Figure 25 3 Route flexible gas line included from fireplace control to equip mentshutoffvalvethroughsideorrearaccessholesinou...

Страница 16: ...leak detection fluid to gas joints Bubbles form ing show a leak 4 Correct all leaks at once Pressure Testing Fireplace Gas Connections 1 Open equipment shutoff valve see Figure 27 2 Open main gas valv...

Страница 17: ...ire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service techni cian or...

Страница 18: ...ING PROCEDURE OPERATING FIREPLACE Continued OPERATING BLOWER OFF ON Auto Off On Switch This blower has three settings ON OFF and AUTO In the ON position the blower will operate constantly In the OFF p...

Страница 19: ...with a mild soap and water mixture Wipe the cabinet to remove dust INSPECTING BURNER Burner Flame Pattern CLEANING AND MAINTENANCE Cleaning Burner Injector Holder and Pilot Air Inlet Hole Cabinet WAR...

Страница 20: ...mocouple damaged 8 Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ignitor...

Страница 21: ...rough 10 4 Clean burner see Cleaning and Mainte nance page 19 or replace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products OBSERVED PROBLEM Burner do...

Страница 22: ...1 Gas leak SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventil...

Страница 23: ...DESA Heating Products Techni cal Service Department at 1 866 672 6040 for referral information When calling DESA Heating Products have ready your name your address model and serial numbers of your fi...

Страница 24: ...satech com 24 ILLUSTRATED PARTS BREAKDOWN MODELS VMH26TPB Shown AND VMH26TNB 12 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 17 19 6 22 31 21 41 42 16 15 18 24 28 34 25 27 20 4 35 12 24 12 1 14...

Страница 25: ...se 1 20 102649 01CK 102649 01CK Branch Support 1 21 099415 09 099415 10 Gas Regulator 1 22 102875 01 102875 01 Regulator Bracket 1 23 101381 01 101381 01 Valve Cover and Piezo 1 24 099387 11 099387 11...

Страница 26: ...Equipment shutoff valve with 1 8 NPT tap THERMOSTATICALLY CONTROLLED BLOWER KIT GA3450T Provides better heat distribution Makes fireplace more efficient Automatically turns off and on as needed BRASS...

Страница 27: ...ed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 4...

Страница 28: ...111043 01B For more information visit www desatech com For more information visit www desatech com 28 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 29: ...________________________________________________________ _______________________________________________________________________________________________ _______________________________________________...

Страница 30: ...as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing...

Отзывы: