OWNER’S MANUAL

LIGHTING

INSTRUCTIONS

Ignitor Button

Figure 29  - Control Knob In The OFF
Position

Control Knob

 WARNING: You must operate

this fireplace with the fireplace
screen in place. Make sure fire-
place screen is installed before
running fireplace.

NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Orange flame will also be
present. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.

OPERATING
FIREPLACE

1.

STOP! Read the safety information,
column 1.

2.

Make sure equipment shutoff valve
is fully open.

3.

Turn control knob clockwise 

Clockwise

to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including near
the floor. If you smell gas, STOP! Fol-
low “B” in the safety information,
column 1. If you don’t smell gas, go
to the next step.

5.

Turn control knob counterclockwise

C-clockwise

 to the PILOT position. Press

in control knob for five (5) seconds
(see Figure 29).

Note:

 You may be running this fire-

place for the first time after hooking
up to gas supply. If so, the control
knob may need to be pressed in for
30 seconds or more. This will allow
air to bleed from the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button.
This will light pilot. The pilot is at-
tached to the front of burner. If
needed, keep pressing ignitor but-
ton until pilot lights.

Note:

 If pilot does not stay lit, refer

to Troubleshooting, pages 20 through
22. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure,
 page 18.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

 If pilot goes out, repeat steps

3 through 7. This fireplace has a
safety interlock system. Wait one (1)
minute before lighting pilot again.

8.

Turn control knob counterclockwise

C-clockwise

 to desired heating level. The

main burner should light. Set control
knob to any heat level between HI
and LO.

Thermocouple

Pilot Burner

Figure 30 - Pilot

Ignitor Electrode

FOR YOUR SAFETY

READ BEFORE

LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

 CAUTION: Do not try to adjust

heating levels by using the equip-
ment shutoff valve.

Continued

Содержание VMH26TPB 14

Страница 1: ...Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or...

Страница 2: ...Note During initial op eration slight smoking could occur due to log curing and fireplace burning manufacturing residues 8 To prevent the creation of soot follow the instructions in Cleaning and Main...

Страница 3: ...wer gas bills Ignitor Button Screen Fireplace Cabinet Logs Control Knob IMPORTANT THIS PACKAGE CONTAINS A FIREPLACE HOOD UNWRAP CARTON AND REMOVE HOOD BEFORE DISCARDING PROTECTIVE PACKAGING 1 2 UNPACK...

Страница 4: ...tallation in structions provided with blower 4 Remove log packaging material and discard packaging Gently place log set on burner support see Figure 3 The log should fit flat against top of burner sup...

Страница 5: ...e atmosphere have a con tinuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable w...

Страница 6: ...pliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maxi...

Страница 7: ...stion and Ventilation for required size of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openin...

Страница 8: ...ects are less than 36 inches from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas CAUTION This fireplace cre ateswarmaircurrents Thesecur r...

Страница 9: ...oor Minimum 10 1 2 Figure 9 Rough Opening for Installing in Wall WARNING If pre wiring do not connect wiring to any electri cal source at this time Install fireplace electrical outlet and connect wiri...

Страница 10: ...on Walls and mantels above the firebox may become hot to the touch If installedproperly thesetempera turesmeettherequirementofthe national product standard Fol low all minimum clearances shown in this...

Страница 11: ...Valve Cover Shield Shoulder Screw Removing Valve Cover Shield 1 Open bottom louver assembly by swinging the assembly down see Fig ure 17 2 Using short Phillips screwdriver re move the screw under the...

Страница 12: ...rear of the valve cover shield and through the rectangular hole in the front of shield see Figure 18 8 Reconnect red wire to switch position 3 Reconnect blue wire to switch posi tion 1 Reconnect gree...

Страница 13: ...Plug power cord to the outlet receptacle not provided as shown in figure 19 Wind the extra cable in power cord and and tie it up with the plastic wire strap see Figure 21 Set the cable bundle between...

Страница 14: ...ly Propane LP Supply Tank External Regulator Attaching Wood Base to Solid Floor For attaching base to solid floors concrete or masonry Note Floor anchors and mounting screws areinhardwarepackage Theha...

Страница 15: ...replace seeFigure25 The flexible gas supply line con nection to the equipment shutoff valve should be accessible 4 Apply pipe joint sealant lightly to male threads of gas connector attached to flexibl...

Страница 16: ...t all leaks at once WARNING Neveruseanopen flame to check for a leak Apply a noncorrosiveleakdetectionfluid toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure external r...

Страница 17: ...e lightpilotwith match To light pilot with match see Manual Lighting Procedure page 18 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If...

Страница 18: ...s 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Now follow step 8 page 17 MANUAL LIGHTING PROCEDURE OPERATING FIREPLACE Continued OPERATING B...

Страница 19: ...Blocked air holes will cre ate soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a quali fied service person Wealsorecommendthatyoukeep...

Страница 20: ...ged 8 Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace pie...

Страница 21: ...ace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products OBSERVED PROBLEM Burner does not light after ODS pilot is lit Delayed ignition of burner Burner...

Страница 22: ...ement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROBLEM...

Страница 23: ...ll DESA International s Technical Service Department at 1 866 672 6040 for referral information When calling DESA International have ready your name your address modelandserialnumbersofyourfireplace h...

Страница 24: ...LASSIC HEARTH FIREPLACE VMH26TPB ILLUSTRATED PARTS BREAKDOWN VMH26TPB 12 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 17 19 6 22 31 21 41 26 42 39 39 16 15 18 24 28 5 34 25 27 20 4 35 12 24 12...

Страница 25: ...e 1 17 100587 01 Brass Screw 6 x 3 8 4 18 098303 02 Regulator Screw 2 19 104335 01CK Outer Shell Base 1 20 102649 01CK Branch Support 1 21 099415 09 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23...

Страница 26: ...ranunfinished birch ready to stain or paint Complete assemblyinstructionsincluded Three sided brass trim kit included EQUIPMENT SHUTOFF VALVE GA5010 For all models Equipment shutoff valve with 1 8 NPT...

Страница 27: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 28: ...or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the own...

Отзывы: