background image

2

107030

COMPACT CLASSIC HEARTH

®

 FIREPLACE

VMH26TPB

®

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate,
or service this fireplace. Improper
use of this fireplace can cause se-
rious injury or death from burns,
fire, explosion, electrical shock, and
carbon monoxide poisoning.

SAFETY
INFORMATION

Carbon Monoxide Poisoning:

 Early signs

of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If
you have these signs, the fireplace may not
be working properly. Get fresh air at once!
Have fireplace serviced.   Some people are
more affected by carbon monoxide than
others. These include pregnant women,
people with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.

Propane/LP Gas:

 Propane/LP gas is odor-

less. An odor-making agent is added to pro-
pane/LP gas. The odor helps you detect a
propane/LP gas leak. However, the odor added
to propane/LP gas can fade. Propane/LP gas
may be present even though no odor exists.

Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this fireplace.

 DANGER: Carbon monoxide

poisoning may lead to death!

WARNING ICON

G 001

 WARNINGS

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.

2.

Do not place propane/LP supply tank(s)
inside any structure. Locate propane/LP
supply tank(s) outdoors.

3.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

4.

This fireplace shall not be installed in
a bedroom or bathroom.

5.

Do not use this fireplace as a wood-
burning fireplace. Use only the logs
provided with the fireplace.

6.

Do not add extra logs or ornaments
such as pine cones, vermiculite, or rock
wool. Using these added items can
cause sooting. Do not add lava rock
around base. Rock and debris could fall
into the control area of fireplace.

7.

This fireplace is designed to be smoke-
less. If logs ever appear to smoke, turn
off fireplace and call a qualified ser-
vice person. 

Note: 

During initial op-

eration, slight smoking could occur due
to log curing and fireplace burning
manufacturing residues.

8.

To prevent the creation of soot, follow
the instructions in Cleaning and Main-
tenance, 
page 19.

9.

Before using furniture polish, wax, car-
pet cleaner, or similar products, turn
heater off.  If heated, the vapors from
these products may create a white pow-
der residue within burner box or on
adjacent walls or furniture.

10. This fireplace needs fresh air ventila-

tion to run properly. This fireplace has
an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS shuts
down the fireplace if not enough fresh
air is available. See Air for Combus-
tion and Ventilation,
 pages 5 through
7. If fireplace keeps shutting off, see
Troubleshooting, pages 20 through 22.

11. Do not run fireplace

• where flammable liquids or vapors

are used or stored.

• under dusty conditions.

12. Do not use this fireplace to cook food

or burn paper or other objects.

13. Do not use fireplace if any part has been

under water. Immediately call a quali-
fied service technician to inspect the
room fireplace and to replace any part
of the control system and any gas con-
trol which has been under water.

14. Turn off and unplug fireplace and let

cool before servicing. Only a qualified
service person should service and re-
pair fireplace.

Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.

Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects in the fireplace.

Fireplace front and screen be-
comes very hot when running
fireplace. Keep children and
adults away from hot surfaces to
avoid burns or clothing ignition.
Fireplace will remain hot for a
time after shutdown. Allow sur-
faces to cool before touching.

Carefully supervise young chil-
dren when they are in the room
with fireplace.

Keep the appliance area clear and
free from combustible materials,
gasoline, and other flammable va-
pors and liquids.

You must operate this fireplace
with a fireplace screen in place.
Make sure fireplace screen is in
place before running fireplace.

 WARNING: Any change to this

fireplace or its controls can be
dangerous.

 WARNING: Do not allow fans

to blow directly into the fireplace.
Avoid any drafts that alter burner
flame patterns. Ceiling fans can
create drafts that alter burner
flame patterns. Altered burner
patterns can cause sooting.

 WARNING: Do not use a

blower insert, heat exchanger
insert, or other accessory not ap-
proved for use with this fireplace.

Содержание VMH26TPB 14

Страница 1: ...Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or...

Страница 2: ...Note During initial op eration slight smoking could occur due to log curing and fireplace burning manufacturing residues 8 To prevent the creation of soot follow the instructions in Cleaning and Main...

Страница 3: ...wer gas bills Ignitor Button Screen Fireplace Cabinet Logs Control Knob IMPORTANT THIS PACKAGE CONTAINS A FIREPLACE HOOD UNWRAP CARTON AND REMOVE HOOD BEFORE DISCARDING PROTECTIVE PACKAGING 1 2 UNPACK...

Страница 4: ...tallation in structions provided with blower 4 Remove log packaging material and discard packaging Gently place log set on burner support see Figure 3 The log should fit flat against top of burner sup...

Страница 5: ...e atmosphere have a con tinuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable w...

Страница 6: ...pliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maxi...

Страница 7: ...stion and Ventilation for required size of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openin...

Страница 8: ...ects are less than 36 inches from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas CAUTION This fireplace cre ateswarmaircurrents Thesecur r...

Страница 9: ...oor Minimum 10 1 2 Figure 9 Rough Opening for Installing in Wall WARNING If pre wiring do not connect wiring to any electri cal source at this time Install fireplace electrical outlet and connect wiri...

Страница 10: ...on Walls and mantels above the firebox may become hot to the touch If installedproperly thesetempera turesmeettherequirementofthe national product standard Fol low all minimum clearances shown in this...

Страница 11: ...Valve Cover Shield Shoulder Screw Removing Valve Cover Shield 1 Open bottom louver assembly by swinging the assembly down see Fig ure 17 2 Using short Phillips screwdriver re move the screw under the...

Страница 12: ...rear of the valve cover shield and through the rectangular hole in the front of shield see Figure 18 8 Reconnect red wire to switch position 3 Reconnect blue wire to switch posi tion 1 Reconnect gree...

Страница 13: ...Plug power cord to the outlet receptacle not provided as shown in figure 19 Wind the extra cable in power cord and and tie it up with the plastic wire strap see Figure 21 Set the cable bundle between...

Страница 14: ...ly Propane LP Supply Tank External Regulator Attaching Wood Base to Solid Floor For attaching base to solid floors concrete or masonry Note Floor anchors and mounting screws areinhardwarepackage Theha...

Страница 15: ...replace seeFigure25 The flexible gas supply line con nection to the equipment shutoff valve should be accessible 4 Apply pipe joint sealant lightly to male threads of gas connector attached to flexibl...

Страница 16: ...t all leaks at once WARNING Neveruseanopen flame to check for a leak Apply a noncorrosiveleakdetectionfluid toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure external r...

Страница 17: ...e lightpilotwith match To light pilot with match see Manual Lighting Procedure page 18 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If...

Страница 18: ...s 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Now follow step 8 page 17 MANUAL LIGHTING PROCEDURE OPERATING FIREPLACE Continued OPERATING B...

Страница 19: ...Blocked air holes will cre ate soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a quali fied service person Wealsorecommendthatyoukeep...

Страница 20: ...ged 8 Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace pie...

Страница 21: ...ace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products OBSERVED PROBLEM Burner does not light after ODS pilot is lit Delayed ignition of burner Burner...

Страница 22: ...ement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROBLEM...

Страница 23: ...ll DESA International s Technical Service Department at 1 866 672 6040 for referral information When calling DESA International have ready your name your address modelandserialnumbersofyourfireplace h...

Страница 24: ...LASSIC HEARTH FIREPLACE VMH26TPB ILLUSTRATED PARTS BREAKDOWN VMH26TPB 12 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 17 19 6 22 31 21 41 26 42 39 39 16 15 18 24 28 5 34 25 27 20 4 35 12 24 12...

Страница 25: ...e 1 17 100587 01 Brass Screw 6 x 3 8 4 18 098303 02 Regulator Screw 2 19 104335 01CK Outer Shell Base 1 20 102649 01CK Branch Support 1 21 099415 09 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23...

Страница 26: ...ranunfinished birch ready to stain or paint Complete assemblyinstructionsincluded Three sided brass trim kit included EQUIPMENT SHUTOFF VALVE GA5010 For all models Equipment shutoff valve with 1 8 NPT...

Страница 27: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 28: ...or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the own...

Отзывы: