background image

25

105273

OWNER’S MANUAL

ACCESSORIES

Purchase these heater accessories from your
local dealer. If they can not supply these
accessories, call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. You can also write to the ad-
dress listed on the back page of this manual.

DAMPER CLAMP - GA6080
(Not Shown)

Permanently opens chimney flue damper
for vented operation. Can be used only with
non-thermostat accessories.

LAVA ROCK - GA6060
(Not Shown)

For all models. Order when additional rock
is desired. (3 lb. bag)

FIREPLACE HOOD

Black - GA6050
Brass - GA6052
Antique Brass - GA6053

For all models. Helps deflect heat away
from mantel or wall above fireplace. Fits
openings 28" to 48" wide.

MANUAL SHUTOFF VALVE -
GA5010

For all models. Manual shutoff valve with 1/8"
NPT tap. Fits 1/2" NPT pipe.

AU

TO

MAN

OFF

ST

ATUS

ON

LO

HI

TEMP

RECEIVER AND HAND-HELD
THERMOSTAT REMOTE
CONTROL KIT - GHRCT

For all models. Allows the gas log heater to
be operated in a manually or thermostati-
cally controlled mode. You can turn the gas
log heater on and off without ever leaving
the comfort of your easy chair.

RECEIVER AND HAND-
HELD REMOTE CONTROL
KIT - GHRC

For all models. Allows the gas log heater to
be turned on and off by using a hand-held
remote control.

WALL-MOUNT THERMOSTAT
SWITCH - GWMT1

(Not Shown)

For all models. The desired comfort setting
can be selected on the wall thermostat and
the log heater will automatically cycle from
pilot to the heat setting selected.

WALL-MOUNT ON/OFF
SWITCH - GWMS2

(Not Shown)

For all models. Allows the gas log heater to
be turned on and off with a wall switch.

Содержание UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER

Страница 1: ...cy or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Re...

Страница 2: ...ore operating heater 7 You must operate this heater with a fire placescreeninplace Makesurefireplace screen is closed before running heater 8 This log heater is designed to be smoke less If logs ever...

Страница 3: ...oduct information 1 Remove logs and heater base assem bly from carton Note Do not pick up heater base assembly by the burner This could damage heater Always handle base assembly by grate 2 Remove all...

Страница 4: ...thods help reduce heat loss in homes Home own ers weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home ownerswanttheirhomesasairtigh...

Страница 5: ...ustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ____________Btu Hr maximum the space can support _______...

Страница 6: ...l connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Co...

Страница 7: ...heatersaddmois ture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Com bustion and Ventila...

Страница 8: ...essory GA6050 GA6052 or GA6053 see Acces sories page 25 18 Model Noncombustible material OK Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot...

Страница 9: ...lf 12 8 A 18 8 20 14 22 163 4 24 20 All minimum distances are in inches Log Set 24 30 36 Models 18 Model 2 1 2 6 8 10 Minimum Non Combustible Material 8 Min 12 15 18 All minimum distances are in inche...

Страница 10: ...fireplace with a working flue and constructed of non combustible material Ifyourheaterisamanuallycontrolledmodel you may use this heater as a vented product There are three reasons for operating your...

Страница 11: ...regulator of heater see Figure 11 IMPORTANT Hold gas regulator with wrench when connecting flexible gas hose 2 Locate two masonry screws in hard ware package 3 Place heater base in fireplace 4 Place...

Страница 12: ...fitting with wrenchwhenconnectingittogas piping and or fittings Installsedimenttrapinsupplylineasshown in Figure 13 Locate sediment trap where it is within reach for cleaning Locate sedi ment trap whe...

Страница 13: ...In Excess Of 1 2 PSIG 1 Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas p...

Страница 14: ...16 Installing Golden Oak One Piece Log Set Figure 17 Installing Golden Oak One Piece Log Set Top View WARNING Failure to posi tion the parts in accordance with these diagrams or failure to use only p...

Страница 15: ...ff a paper burning smell Open damper or window to vent smell This will only last a few hours Note Home owners generally prefer to operate their heater with the chimney damper closed This will put all...

Страница 16: ...o turn the burner on and off When turning burner off the pilot will remain lit GHRCT Operation 2b Select the MAN manual or AUTO button on the hand held remote con trol unit see Figure 21 page 17 In ma...

Страница 17: ...t tern Figure23showsanincorrectpilotflame pattern Theincorrectpilotflameisnottouch ing the thermocouple This will cause the thermocouple to cool When the thermo couple cools the heater will shut down...

Страница 18: ...older for dust and dirt see Figure 24 3 Blow air through the ports slots and holes in the burner Figure 24 Injector Holder On Outlet Burner Tube Burner Tube Injector Holder May Be Brass or Aluminum De...

Страница 19: ...Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Re...

Страница 20: ...requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe minimum...

Страница 21: ...er burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is common w...

Страница 22: ...MAX GOLDEN OAK LOG MODELS VYD18NRA VYD24NRA VYD30NRA AND VYD36NR 4 13 13 14 22 13 8 18 7 6 9 1 12 5 16 15 17 3 11 2 10 24 23 23 19 19 20 21 26 25 O F F P I L O T O N H I L O O F F P I L O T O N H I L...

Страница 23: ...84 38 Screw 8 x 38 7 14 104384 01 102775 06CK 102775 08CK 102775 08CK Painted Base Assy 1 15 098271 07 098271 07 098271 07 098271 07 Ignitor Cable 1 16 102445 01 102445 01 102445 01 102445 01 Piezo Ig...

Страница 24: ...FICATIONS Golden Oak Golden Oak 18 Remote 24 30 and 36 Ready Remote Ready Btu Variable 16 000 30 000 20 000 39 000 Type Gas Natural Gas Only Natural Gas Only Ignition Piezo Piezo Pressure Manifold 3 5...

Страница 25: ...8 wide MANUAL SHUTOFF VALVE GA5010 Forallmodels Manualshutoffvalvewith1 8 NPT tap Fits 1 2 NPT pipe AUTO MAN OFF STA TUS ON LO HI TEMP RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT GHRCT For al...

Страница 26: ...to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER E...

Отзывы: