106828

OWNER’S MANUAL

For more information, visit www.desatech.com

SPECIFICATIONS

SBVBN(C)

SBVBP(C)

21,000-30,000 Btu/h

20,000-28,000 Btu/h

Gas Type

Natural

Propane/LP

Ignition

Piezo

Piezo

Manifold Pressure

3.5" w.c.

10.0" w.c.

Minimum Inlet Supply Pressure

4.5" w.c.

11.0" w.c.

Thermal Efficiency

70%

70%

Dimension, Inches/mm (HxWxD)

Stove and Burner System*

27" x 26 

1

/

4

" x 20"

27" x 26 

1

/

4

" x 20"

685.8 x 660.4 x 635mm

685.8 x 660.4 x 635mm

Carton (Insert Only)

23" x 33" x 23"

23" x 33" x 23"

584.2 x 838.2 x 584.2mm

584.2 x 838.2 x 584.2mm

Weight, lbs/kg

Burner System

70 lbs/31.8 kg

70 lbs/31.8 kg

Shipping

75 lbs/34 kg

75 lbs/34 kg

* When installed in Amity cast iron stove body (SCIVFC Series and PSCIVFC Series).

ACCESSORIES

Purchase these stove and burner system
accessories from your local dealer. If they
can not supply these accessories, call DESA
International’s Sales Department at 1-800-
432-2382. for information. You can also
write to the address listed on the back page
of this manual.

WALL MOUNTED
THERMOSTAT CONTROL
KIT  GWMT1 (Not Shown)

Allows easy wall access to the operation of
your burner system. This will allow you
thermostatic control with the convenience
of a wall switch.

THERMOSTATICALLY-
CONTROLLED BLOWER KIT
DA3610TA

Provides better heat distribution. Blower
turns off and on automatically, as needed.
Complete installation and operation instruc-
tions included in this manual.

AU

TO

ON

OFF

COOLER

W

ARMER

TEMP

RECEIVER AND HAND-HELD
REMOTE CONTROL KIT
GHRC

For all models. Allows the heater to be
turned on and off conveniently.

RECEIVER AND HAND-HELD
THERMOSTAT REMOTE
CONTROL KIT - GHRCTA

Allows the burner system to be operated in
a manually or thermostatically controlled
mode. You can adjust your heat settings and
turn the heater on or off without leaving the
comfort of your easy chair.

WALL MOUNTED ON/OFF
SWITCH - GWMS2
(Not Shown)

Allows burner system to be turned on and
off with a wall switch.

Содержание SBVBN(C)

Страница 1: ...fied installer ser vice agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result causingpropertydamage personalinjury orloss of life...

Страница 2: ...properlyseatedandsealed If this unit is not properly installed by a qualifiedservicepersonwithglassdoorprop erlyseatedandsealed gas leakagecanoccur Carbon Monoxide Poisoning Early signs of carbon mono...

Страница 3: ...ith burner systemiscleanburningandventsvertically Heat is generated by both realistic flames and glowing embers When used without the blower accessory the stove with burner system requires no electric...

Страница 4: ...is stove is a freestanding unit de signed to set directly on the floor If your stove is to be installed directly on carpeting vinyl tile or any combustible material other than wood it must be installe...

Страница 5: ...tach bottom components to stove body seeFigure7 Reststoveondropclothor blanket to avoid scratching stove edges 7 Remove remaining pallet wood at tached to bottom of stove body see Figure 8 Use an adju...

Страница 6: ...is for door leveling adjustment 11 Check general catch bolt alignment with door claw Make final adjustment and door leveling after stove is in nor mal standing position 12 Carefully lift stove back up...

Страница 7: ...cover by loosening the 8 mounting screws see Figure 16 3 Align the holes in the top mounting tabs of blower with the holes in wall of rear cover Using the 4 screws provided mount blower and tighten s...

Страница 8: ...ouch the blower wheel while in operation WARNING Failure to position the parts in accordance with sup plied diagrams or failure to use only parts specifically approved withthisheatermayresultindam age...

Страница 9: ...aintain its balance between the combus tion air intake and the flue gas exhaust Certain limitations apply to vent configura tions and must be strictly followed 5 Connect one terminal of the wire from...

Страница 10: ...ilding codes You must follow all local building codes Note Wheninstallinginachase youshould insulate the chase as you would the outside walls of your home This is especially im portant in cold climate...

Страница 11: ...ge or loss of life RELINING SYSTEMS Suitability and approval of relining ma terials should be determined Condition size height and termina tion of the chimney to be relined must be determined No subst...

Страница 12: ...shutoffs Othersymptomsoffluegasspillage at the draft hood include condensation on walls and windows and or noticeable odors Spillage may also result in the release of carbonmonoxide acolorless odorle...

Страница 13: ...t resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench approved flexible gas line with gas con nector if allowed by local codes not provided An...

Страница 14: ...f 1 2 PSIG 3 5 kPa 1 Disconnectappliance with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping systems Pressures in excess of 1 2 psig 3 5 kPa will damage...

Страница 15: ...ictured in Figure 34 If wires are not connected as shown the switch will not work 2 Route the 25 ft wire through openings provided on the sides of the burner sys tem to a convenient location to mount...

Страница 16: ...e not connected as shown the ther mostat will not work 4 Route the wire to a convenient loca tion to mount your thermostat no out side wall IMPORTANT The wire must not exceed 25 feet in length The the...

Страница 17: ...move glass door to install logs lava rock and ember material To remove glass door you must first remove the front panel on stove body Figure 39 Installing Battery in Hand Held Remote Control Unit GHRC...

Страница 18: ...S Figure 43 Installing Log No 1 Figure 44 Installing Log No 2 Figure 45 Installing Log No 3 Figure 46 Installing Log No 4 WARNING The glass door must be securely in place before running this burner sy...

Страница 19: ...r turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or ex...

Страница 20: ...ation 2b Press the AUTO ON OFF button on the hand held remote control see Figure 50 The lights to the left of the button will show AUTO ON or OFF In the ON mode the burners will ignite The heater is i...

Страница 21: ...r cover when standing in front of stove with burner system in stalled The DA3610TA thermostatically con trolled blower has an ON setting and an OFF setting The blower will only run whentheswitchisinth...

Страница 22: ...rt or lint WARNING Only parts sup pliedbythemanufacturershould be used when replacing broken ordamagedglassdoorpanel see ReplacementParts page26 This glass door panel is a complete unit No substitute...

Страница 23: ...valve not fully open 4 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is...

Страница 24: ...or a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 22 or replace burner orif...

Страница 25: ...l valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Burner system produces unwanted odor...

Страница 26: ...to disconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwa...

Страница 27: ...Sales Department at 1 800 432 2382 for information You can also write to the address listed on the back page of this manual WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 Not Shown Allows easy wall access...

Страница 28: ...6828 For more information visit www desatech com SBVBN C AND SBVBP C ILLUSTRATED PARTS BREAKDOWN SBVBN C SBVBP C LO H I P I L O T OFF ON 4 4 17 18 19 21 23 1 23 4 23 2 23 3 27 4 22 10 16 11 8 1 25 4 1...

Страница 29: ...16 107195 01 Bracket Spill Switch 1 17 106036 01 Burner Natural 1 106036 02 Burner Propane LP 1 18 104506 16 Orifice Natural 1 104506 17 Orifice Propane LP 1 19 104507 01 Brass Elbow 1 20 901063 01 B...

Страница 30: ...URNER SYSTEM 106828 For more information visit www desatech com SBVBN C AND SBVBP C ILLUSTRATED PARTS BREAKDOWN AMITY SCIVFC SERIES PSCIVFC SERIES Indicates Color Suffix Designation 2 5 8 7 4 6 5 5 7...

Страница 31: ...al Per Stove 1 104175 05 One Leg Forest Green 4 Total Per Stove 1 104175 06 One Leg Metallic Charcoal 4 Total Per Stove 1 104175 07 One Leg Porcelain Enamel Red 4 Total Per Stove 1 104175 08 One Leg P...

Страница 32: ...ated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OT...

Отзывы: