background image

19

106828

OWNER’S MANUAL

For more information, visit www.desatech.com

TO TURN OFF GAS

TO APPLIANCE

1.

Set ON/OFF switch located on rear
cover to “OFF”.

2a. Open lower panel.

2b.

If Using Optional Hand-Held Remote:

Set selector switch in the OFF posi-
tion to prevent draining battery.

3.

Turn off all electrical power to the
appliance if service is to be performed.

4.

Push in gas control knob slightly and
turn clockwise 

 to “OFF”.

5.

Close lower panel.

Shutting Off Burners Only (pilot
stays lit)

You may shut off the burners and keep
the pilot lit by doing one of the following:

1.

Turn control knob clockwise 
to the PILOT position.

2.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.

Remove glass door (see Removing/
Replacing Glass Door
, page 17).

2.

Follow steps 1 through 8 under Light-
ing Instructions
.

3.

Depress control knob and light pilot
with match.

4.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 10 through 14, column 2.

5.

Replace glass door (see Removing/
Replacing Glass Door
, page 17).

OPERATING STOVE
WITH B-VENT
BURNER SYSTEM

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor's phone. Follow
the gas supplier's instructions.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don't try to repair it, call a
qualified service technician. Force or
attempted repair may result in a fire
or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician
to inspect the appliance and to re-
place any part of the control sys-
tem and any gas control which has
been under water.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information
in column one.

2.

Set ON/OFF switch located on rear
cover to “OFF”.

3.

Open lower panel.

4.

Turn off all electric power to the
burner system.

5.

Push in gas control knob slightly and
turn clockwise 

 to “OFF”.

6.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation in column one. If you don't
smell gas, go to the next step.

7.

The pilot is located by the main
burner and should not require ac-
cessing for lighting.

8.

Turn knob on gas control counter-
clockwise 

 to “PILOT”.

9.

Push in control knob all the way and
hold. Immediately light the pilot by
repeatedly depressing the piezo
spark ignitor until a flame appears.
Continue to hold for about one (1)
minute after the pilot is lit. Release
knob and it will pop back. Pilot
should remain lit. If it goes out, re-
peat steps 5 through 8.
• If knob does not pop up when re-

leased, stop and immediately call
your service technician or gas
supplier.

• If the pilot will not stay lit after sev-

eral tries, turn the gas control knob
to “OFF” and call your service
technician or gas supplier.

10. Turn gas control counterclockwise

 to “ON”.

11. Turn on all electric power to the

burner system.

12. Turn the ON/OFF switch to ON

position.

13. This valve is equipped with a HI/LO

feature Set burner system input as
desired.

14. Close lower panel.

Figure 48 - Control Valve

LO HI

OFF

ON

PI

LO

T

Gas Control
Knob

Variable
Control Knob

Piezo Ignitor

Continued

Содержание SBVBN(C)

Страница 1: ...fied installer ser vice agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result causingpropertydamage personalinjury orloss of life...

Страница 2: ...properlyseatedandsealed If this unit is not properly installed by a qualifiedservicepersonwithglassdoorprop erlyseatedandsealed gas leakagecanoccur Carbon Monoxide Poisoning Early signs of carbon mono...

Страница 3: ...ith burner systemiscleanburningandventsvertically Heat is generated by both realistic flames and glowing embers When used without the blower accessory the stove with burner system requires no electric...

Страница 4: ...is stove is a freestanding unit de signed to set directly on the floor If your stove is to be installed directly on carpeting vinyl tile or any combustible material other than wood it must be installe...

Страница 5: ...tach bottom components to stove body seeFigure7 Reststoveondropclothor blanket to avoid scratching stove edges 7 Remove remaining pallet wood at tached to bottom of stove body see Figure 8 Use an adju...

Страница 6: ...is for door leveling adjustment 11 Check general catch bolt alignment with door claw Make final adjustment and door leveling after stove is in nor mal standing position 12 Carefully lift stove back up...

Страница 7: ...cover by loosening the 8 mounting screws see Figure 16 3 Align the holes in the top mounting tabs of blower with the holes in wall of rear cover Using the 4 screws provided mount blower and tighten s...

Страница 8: ...ouch the blower wheel while in operation WARNING Failure to position the parts in accordance with sup plied diagrams or failure to use only parts specifically approved withthisheatermayresultindam age...

Страница 9: ...aintain its balance between the combus tion air intake and the flue gas exhaust Certain limitations apply to vent configura tions and must be strictly followed 5 Connect one terminal of the wire from...

Страница 10: ...ilding codes You must follow all local building codes Note Wheninstallinginachase youshould insulate the chase as you would the outside walls of your home This is especially im portant in cold climate...

Страница 11: ...ge or loss of life RELINING SYSTEMS Suitability and approval of relining ma terials should be determined Condition size height and termina tion of the chimney to be relined must be determined No subst...

Страница 12: ...shutoffs Othersymptomsoffluegasspillage at the draft hood include condensation on walls and windows and or noticeable odors Spillage may also result in the release of carbonmonoxide acolorless odorle...

Страница 13: ...t resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench approved flexible gas line with gas con nector if allowed by local codes not provided An...

Страница 14: ...f 1 2 PSIG 3 5 kPa 1 Disconnectappliance with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping systems Pressures in excess of 1 2 psig 3 5 kPa will damage...

Страница 15: ...ictured in Figure 34 If wires are not connected as shown the switch will not work 2 Route the 25 ft wire through openings provided on the sides of the burner sys tem to a convenient location to mount...

Страница 16: ...e not connected as shown the ther mostat will not work 4 Route the wire to a convenient loca tion to mount your thermostat no out side wall IMPORTANT The wire must not exceed 25 feet in length The the...

Страница 17: ...move glass door to install logs lava rock and ember material To remove glass door you must first remove the front panel on stove body Figure 39 Installing Battery in Hand Held Remote Control Unit GHRC...

Страница 18: ...S Figure 43 Installing Log No 1 Figure 44 Installing Log No 2 Figure 45 Installing Log No 3 Figure 46 Installing Log No 4 WARNING The glass door must be securely in place before running this burner sy...

Страница 19: ...r turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or ex...

Страница 20: ...ation 2b Press the AUTO ON OFF button on the hand held remote control see Figure 50 The lights to the left of the button will show AUTO ON or OFF In the ON mode the burners will ignite The heater is i...

Страница 21: ...r cover when standing in front of stove with burner system in stalled The DA3610TA thermostatically con trolled blower has an ON setting and an OFF setting The blower will only run whentheswitchisinth...

Страница 22: ...rt or lint WARNING Only parts sup pliedbythemanufacturershould be used when replacing broken ordamagedglassdoorpanel see ReplacementParts page26 This glass door panel is a complete unit No substitute...

Страница 23: ...valve not fully open 4 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is...

Страница 24: ...or a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 22 or replace burner orif...

Страница 25: ...l valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Burner system produces unwanted odor...

Страница 26: ...to disconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwa...

Страница 27: ...Sales Department at 1 800 432 2382 for information You can also write to the address listed on the back page of this manual WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 Not Shown Allows easy wall access...

Страница 28: ...6828 For more information visit www desatech com SBVBN C AND SBVBP C ILLUSTRATED PARTS BREAKDOWN SBVBN C SBVBP C LO H I P I L O T OFF ON 4 4 17 18 19 21 23 1 23 4 23 2 23 3 27 4 22 10 16 11 8 1 25 4 1...

Страница 29: ...16 107195 01 Bracket Spill Switch 1 17 106036 01 Burner Natural 1 106036 02 Burner Propane LP 1 18 104506 16 Orifice Natural 1 104506 17 Orifice Propane LP 1 19 104507 01 Brass Elbow 1 20 901063 01 B...

Страница 30: ...URNER SYSTEM 106828 For more information visit www desatech com SBVBN C AND SBVBP C ILLUSTRATED PARTS BREAKDOWN AMITY SCIVFC SERIES PSCIVFC SERIES Indicates Color Suffix Designation 2 5 8 7 4 6 5 5 7...

Страница 31: ...al Per Stove 1 104175 05 One Leg Forest Green 4 Total Per Stove 1 104175 06 One Leg Metallic Charcoal 4 Total Per Stove 1 104175 07 One Leg Porcelain Enamel Red 4 Total Per Stove 1 104175 08 One Leg P...

Страница 32: ...ated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OT...

Отзывы: