background image

7

105500

OWNER’S MANUAL

 WARNING: Never touch the

blower wheel while in operation.

7.

Peel off the backing paper and stick the
supplied wiring diagram decal on the
inside of rear cover on right side oppo-
site control.

 WARNING: Failure to position

the parts in accordance with sup-
plied diagrams or failure to use
only parts specifically approved
with this heater may result in dam-
age or personal injury.

8.

Connect or reconnect gas supply to fire-
place per Connecting Fireplace to Gas
Supply
 on page 13 of this manual.

INSTALLING OPTIONAL
BLOWER ACCESSORY

1.

Align the holes in the top mounting tabs
of blower with holes in wall of rear
cover (see Figure 16). Using the 4
screws provided, mount blower and
tighten screws securely.

Note:

 For DA3610T, make sure the ther-

mal switch has been properly installed
to fit against the back of the firebox.

2.

Make sure all wire connections to ter-
minals on blower motor (and thermal
switch where applicable) are securely
attached and that the screw retaining
the green ground wire is tight.

3.

Place speed control on left inside of rear
cover and push the plastic control shaft
through opening (see Figure 16).

4.

While supporting speed control, secure
control shaft with lock nut by pushing and
turning lock nut with pliers clockwise
until tight against the side of rear cover.
Place control knob provided onto shaft
(see Figure 16).

5.

Plug in blower power cord.

6.

Check to make sure that the power cord
is completely clear of the blower wheel
and that there are no other foreign ob-
jects in blower wheel. Turn blower on
and check for operation. Turn blower
off by rotating knob fully counterclock-
wise before continuing.

NOTICE: If installing blower in an
existing fireplace with gas con-
nections, shut off gas supply and
disconnect heater from gas sup-
ply. Contact a qualified service
person to do this.

Attaching Thermal Switch to
DA3610T Thermostatically
Controlled Blower

When installing the DA3610T thermostati-
cally controlled blower accessory, you must
first secure the thermal switch to the blower.

1.

Remove the two hex head screws on the
blower assembly as shown in Figure 15.

2.

Place the green wire between the bot-
tom hole on the thermal switch bracket
and the bottom hole on the blower as-
sembly.  Insert one of the hex screws
into all three pieces and tighten.

3.

Insert the top screw through the ther-
mal switch bracket and into the blower
assembly. Tighten screw.

4.

Connect the blue wire on the blower
assembly to the right side of the ther-
mal switch.

5.

Connect the black wire to the left side
of the thermal switch.

Installing GA3700/DA3610T
Blowers

 WARNING: A qualified ser-

vice person must connect fire-
place to gas supply. Follow all
local codes.

Figure 15 - Attaching Thermal Switch to
DA3610T Thermostatically Controlled
Blower Accessory

Figure 16 - Installing Optional Blower Accessory (Thermostat Model DA3610T Shown)

FREESTANDING
FIREPLACE
ASSEMBLY

Continued

Blower

Mounting Screws
(Included in
Hardware Pack)

Blower
Control Knob

Control
Shaft

Rear Cover

Speed Control

Power Cord

Lock
Nut

White
Wire

Blue
Wire

Green
Ground Wire

Black
Wire

Wiring
Diagram
Decal

Continued

Thermal
Switch
with
Bracket

Black
Wire

White Wire

Green
Wire

Blue Wire

Hex Head
Screws

Blower
Assembly

Содержание SBVBN(A)

Страница 1: ...res Forassistance or additional information consultaqualifiedinstaller service agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not prohibite...

Страница 2: ...qualified service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide Poisoning Early signsofcarbonmonoxidepoisoningresemble theflu withheadaches dizziness ornause...

Страница 3: ...d vents vertically Heat is gener ated by both realistic flames and glowing embers When used without the blower ac cessory the fireplace requires no electricity making it ideal for emergency backup hea...

Страница 4: ...igure 4 on page 5 4 This stove is a freestanding unit de signed to set directly on the floor If your fireplace is to be installed directly on carpeting vinyl tile or any combus tible material other th...

Страница 5: ...ing Down Stove On Side Figure 8 Removing Pallet Wood From The Bottom of The Stove Figure 6 Removing Back Panel Bolt Product Identification Label Back Stove Panel Pallet Wood Bolt Pallet Wood Bottom Of...

Страница 6: ...p nut is a bolt stop and the bot tom nut is for door leveling adjustment 12 Check general catch bolt alignment with door claw Make final adjustment and door leveling after stove is in nor mal standing...

Страница 7: ...jects in blower wheel Turn blower on and check for operation Turn blower off by rotating knob fully counterclock wise before continuing NOTICE If installing blower in an existing fireplace with gas c...

Страница 8: ...nearby combustibles This appli ance is equipped with a safety control sys tem designed to protect against improper venting of combustion products It is very important that the venting system maintain...

Страница 9: ...osure walls should have a fire rating equal to or greater than the floors through which the gas vent passes except in single or two family dwellings Situate the gas vent in the structure so that it ca...

Страница 10: ...should be relined with appropriate listed relining systems Cleanout access may be required NOTICE Consult the authority having jurisdiction in your area regarding listed chimney liner venting applicat...

Страница 11: ...c gas A simple spillage test can be con ducted if spillage is suspected See Checking Gas Connection pages 13 and 14 CAUSES OF SPILLAGE AND CORRECTIVE ACTION Incorrect Vent Sizing If the vent is too sm...

Страница 12: ...ector if allowed by local codes not provided AnA G A design certifiedmanualshutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur chase the A G A design certified man...

Страница 13: ...ation Items Needed 5 16 hex socket wrench or nut driver sealant resistant to propane LP gas not provided 1 Open lower door panel 2 Route flexible gas line provided by installer from manual shutoff val...

Страница 14: ...Open propane LP supply tank valve for propane LP fireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is in the OFF position 4 Chec...

Страница 15: ...at sources such as lamps direct sun light fireplace or heat and air condi tioning ducts WARNING Do not connect this thermostat to a power source Electrical shock and or fire hazard will occur 5 Gently...

Страница 16: ...s seeFigure35 5 Place receiver into valve bracket and align holes see Figure 36 6 Use push in fasteners included with receiver to secure to bracket 7 Connect the wires from the receiver to the valve a...

Страница 17: ...Figure 41 Installing Log No 2 Figure 42 Installing Log No 3 Figure 43 Installing Log No 4 WARNING The glass door must be securely in place before running this fireplace Do not run this fireplace if g...

Страница 18: ...turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or expl...

Страница 19: ...on the hand held remote control unit Figure 47 Setting the GHRCT Selector Switch control Knob and Flame Adjustment Knob for Remote Operation TEMP STATUS HI LO MAN ON AUTO OFF Figure 48 Hand Held Ther...

Страница 20: ...Blower controls are located on the left side of the switch bracket to the left just inside the louver panel Both the GA3700 manual blower and the DA3610T thermostatically controlled blower have an ON...

Страница 21: ...e used when replacing broken ordamagedglassdoorpanel see ReplacementParts page25 This glass door panel is a complete unit No substitute materials may be used If glass has been broken carefully remove...

Страница 22: ...pen 4 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located behind the...

Страница 23: ...from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 21 or replace burner orifice 1 Adjust the log set so that the flame does n...

Страница 24: ...Control valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted o...

Страница 25: ...ng controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarrantycoveragefor parts replac...

Страница 26: ...Pressure 4 5 w c 11 0 w c Thermal Efficiency 70 70 Dimension Inches mm HxWxD Fireplace 27 x 26 x 25 27 x 26 x 25 685 8 x 660 4 x 635mm 685 8 x 660 4 x 635mm Carton Insert Only 23 x 33 x 23 23 x 33 x...

Страница 27: ...ireplaces THERMOSTATICALLY CONTROLLED BLOWER KIT DA3610T Provides better heat distribution Blower turns off and on automatically as needed Completeinstallationandoperationinstruc tions included in thi...

Страница 28: ...ENT FREESTANDING FIREPLACE 105500 ILLUSTRATED PARTS BREAKDOWN SBVBN A SBVBP A LO H I P I L O T OFF ON 24 17 18 19 21 23 1 23 4 23 2 23 3 26 27 4 22 9 4 1 10 11 8 2 4 4 7 28 13 14 15 16 20 20 25 5 29 3...

Страница 29: ...urner Propane LP 1 18 104506 03 Orifice Natural 1 104506 04 Orifice Propane LP 1 19 104507 01 Brass Elbow 1 20 104508 01 Brass Fitting 2 21 105493 01 Aluminum Tubing Assy 1 22 105325 01 Air Deflector...

Страница 30: ...repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXP...