Vanguard Firewerks VTDMV24NA Скачать руководство пользователя страница 2

www.desatech.com

114926-01C

2

WARNING:  Improper  installation,  adjustment,  altera-
tion, service or maintenance can cause injury or prop-
erty damage. Refer to this manual for correct installation 
and  operational  procedures.  For  assistance  or  addi-
tional information consult a qualified installer, service 
agency or the gas supplier.

WARNING:  This  appliance  is  for  installation  only  in 
a  solid-fuel  burning  masonry  or  UL127  factory-built 
fireplace, constructed of noncombustible material and 
connected to a working flue. (See page 6 for minimum 
flue opening.)

WARNING: This is a gas-fired heater. It uses air (oxy-
gen) from the room in which it is installed. Provisions 
for  adequate  combustion  and  ventilation  air  must  be 
provided. Refer to the 

National Fuel Gas Codes, ANSI 

Z233.1/NFPA  54,  Section  5.3, Air  for  Combustion  and 
Ventilation.

This appliance may be installed in an aftermarket,* per-
manently located, manufactured (mobile) home, where 
not prohibited by local codes.
This appliance is only for use with the type of gas indi-
cated on the rating plate. This appliance is not convert-
ible for use with other gases. 

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

State of Massachusetts: The installation must be made 
by a licensed plumber or gas fitter in the Commonwealth 
of Massachusetts.

TABLE OF CONTENTS

Safety Information ............................................... 3
Local Codes ........................................................ 4
Product Identification ........................................... 5
Unpacking ........................................................... 5
Product Features ................................................. 5
Installation ........................................................... 5
Operating Appliance .......................................... 10
Inspecting Burners .............................................11
Cleaning and Maintenance ................................ 12

Service Hints ..................................................... 12
Technical Service .............................................. 12
Replacement Parts ............................................ 12
Troubleshooting ................................................. 13
Specifications .................................................... 17
Accessories ....................................................... 17
Wiring Diagram .................................................. 17
Illustrated Parts Breakdown and Parts List ....... 18
Warranty Information ...........................Back Cover

Содержание Firewerks VTDMV24NA

Страница 1: ...ny other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s...

Страница 2: ...33 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This app...

Страница 3: ...be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Do not pla...

Страница 4: ...rovided by other means screens shall have openings for introduction of combustion air 8 Toreducethecreationofsoot followtheinstruc tions in Cleaning and Maintenance page 12 SAFETY INFORMATION Continue...

Страница 5: ...d ser vice person must install heater Follow all local codes WARNING Before installing in a solid fuel burning replace the chimney ue and rebox must be cleaned of soot creo sote ashes and loose paint...

Страница 6: ...nly in a solid fuel burning or UL127 factory built re place constructed of noncombustible material and connected to a working ue The replace chimney must have a permanent vent opening to outside with...

Страница 7: ...e control valve INSTALLATION Continued CAUTION Never connect propane LP unit directly to the propane LP supply This unit re quiresanexternalregulator not supplied Install the external regulator betwee...

Страница 8: ...om External Regulator 11 W C to 14 W C Pressure 3 Min Pipe Cap Tee Nipple Joint CHECKING GAS CONNECTIONS WARNING Testallgaspiping and connections internal and external to unit for leaks after installi...

Страница 9: ...valve 3 Make sure control knob of appliance is in the OFF position 4 Check all joints from equipment shutoff valve to gas control see Figure 9 or 10 Apply noncorrosive leak detection uid to all joint...

Страница 10: ...d separately see Accessories page 17 Follow instructions included with the remote control OPERATING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING Keep ue open when operating unit WARNING If y...

Страница 11: ...thermocouple to cool When the thermocouple cools the appliance will shut down If pilot ame pattern is incorrect as shown in Figure 16 turn appliance off see To Turn Off Gas to Appliance page 10 see Tr...

Страница 12: ...ropane LPunits only propane LPgas supply may be low You may feel your gas pressure is too low If so contact your local propane LP or natural gas supplier TECHNICAL SERVICE You may have further questio...

Страница 13: ...as lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 External gas regulator setting is incorrect When ignitor button is pressed there is no spark at ODS pilot When...

Страница 14: ...n burner s see Cleaning and Maintenance page 12 1 Clean burner see Cleaning and Maintenance page 12 or replace burner ori ce 2 Replace damaged burner 3 Replace gas regulator 4 Correct external gas reg...

Страница 15: ...oved from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 6 4 Clean burners see Cleaning and Maintenance page 12 or replace bur...

Страница 16: ...nding while heating or contracting while cooling 1 Appliance burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply propane LP onl...

Страница 17: ...HAND HELD REMOTE CONTROL KIT HRC100 Allows the gas log heater to be turned on and off using a hand held remote control A wall mount docking station is included CLEANING KIT GCK Not Shown Your vented g...

Страница 18: ...www desatech com 114926 01C 18 ILLUSTRATED PARTS BREAKDOWN MODELS VTDMV24NA VTDMV24PA VTDMV18NA AND VTDMV18PA 1 2 3 4 5 6 17 16 15 7 8 9 10 11 12 14 13...

Страница 19: ...Pilot Assembly 1 103778 01 Pilot Assembly 1 11 111828 01 Brass Fitting 2 12 114930 01 Pilot Bracket 1 13 26205 Gas Ori ce 1 23109 Gas Ori ce 1 14 114930 01 Venturi 1 114936 01 Venturi 1 15 Burner 1 16...

Страница 20: ...The heater MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original conditi...

Отзывы: