Vanguard Firewerks VTDMV24NA Скачать руководство пользователя страница 11

www.desatech.com

114926-01C

11

NOTICE: You must light the pilot 

before using the hand-held re-

mote control unit. See 

Lighting 

Instructions

 on page 10.

After lighting, let pilot flame burn for about 

one minute. Turn control knob to ON posi-

tion. Adjust flame adjustment knob anywhere 

between  HI  and  LO.  Flip AUTO/OFF/ON 

switch  to AUTO.  Slide  the  selector  switch 

to  the  REMOTE  position  (see  Figure  13).  

Note: 

The  burner  may  light  if  hand-held 

remote was on when selector switch was last 

turned off. You can now turn the burner on and 

off with the hand-held remote control unit. 

IMPORTANT:

 Do not leave the selector switch 

in the REMOTE or ON position when the pilot 

is not lit. This will drain the battery.

Figure 15 - Correct Pilot Flame Pattern 
(Your pilot may vary from pilot shown)

Figure 16 - Incorrect Pilot Flame Pattern 

(Your pilot may vary from pilot shown)

Thermocouple

Thermocouple

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat-

terns often.

PILOT FLAME PATTERN

You can view the pilot light through the pilot view-

ing hole on the pilot bracket. This is located under 

the front grate bar on the right side of the log set.
Figure 15 shows a correct pilot flame pattern. Figure 

16 shows an incorrect pilot flame pattern. The incor-

rect pilot flame is not touching the thermocouple. 

This will cause the thermocouple to cool. When the 

thermocouple cools, the appliance will shut down.
If pilot flame pattern is incorrect, as shown in 

Figure 16
•  turn appliance off (see

 To Turn Off Gas to 

Appliance, 

page 10)

•  see 

Troubleshooting

, page 13

Note:

 The pilot flame on natural gas units will 

have a slight curve but flames should be blue and 

have no yellow or orange color.

Figure 13 - Setting the Selector Switch, 

Control Knob and Flame Adjustment 

Knob for Remote Operation 

Selector Switch in 
REMOTE Position

REMOTE
OFF
ON

Piezo 
Ignitor

Control Knob

Flame 
Adjustment 
Knob

ON/OFF SERIES (MODEL HRC100)

Hold the control button on the hand-held remote 

until burner turns on. Hold the control button 

again until burner turns off (see Figure 14).

To  Lock

  press  both  buttons  on  hand-held 

remote control until light stops flashing. Hand-

held remote control is now locked. If the fire is 

on it will be turned off automatically. In the 

locked state, the light will not light up when 

any button is pressed. 

To Unlock

 press both buttons together on hand-

held remote control until the light stops flashing. 

The hand-held remote is now unlocked.

Figure 14 - On/Off Hand-Held Remote 

Control Unit (HRC100)

Control Button 
Turns Burner 
On and Off

OPERATING APPLIANCE

Continued

BURNER FLAME PATTERN

Figure 17 shows correct burner flame pattern.

NOTICE: Do not mistake orange 

flames with yellow tipping. Dirt 

or other fine particles are burned 

by  appliance,  causing  brief 

patches of orange flame.

Figure 17 - Correct Burner Flame Pattern

Yellow Flames 
with Orange 
Streaks

Содержание Firewerks VTDMV24NA

Страница 1: ...ny other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s...

Страница 2: ...33 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This app...

Страница 3: ...be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Do not pla...

Страница 4: ...rovided by other means screens shall have openings for introduction of combustion air 8 Toreducethecreationofsoot followtheinstruc tions in Cleaning and Maintenance page 12 SAFETY INFORMATION Continue...

Страница 5: ...d ser vice person must install heater Follow all local codes WARNING Before installing in a solid fuel burning replace the chimney ue and rebox must be cleaned of soot creo sote ashes and loose paint...

Страница 6: ...nly in a solid fuel burning or UL127 factory built re place constructed of noncombustible material and connected to a working ue The replace chimney must have a permanent vent opening to outside with...

Страница 7: ...e control valve INSTALLATION Continued CAUTION Never connect propane LP unit directly to the propane LP supply This unit re quiresanexternalregulator not supplied Install the external regulator betwee...

Страница 8: ...om External Regulator 11 W C to 14 W C Pressure 3 Min Pipe Cap Tee Nipple Joint CHECKING GAS CONNECTIONS WARNING Testallgaspiping and connections internal and external to unit for leaks after installi...

Страница 9: ...valve 3 Make sure control knob of appliance is in the OFF position 4 Check all joints from equipment shutoff valve to gas control see Figure 9 or 10 Apply noncorrosive leak detection uid to all joint...

Страница 10: ...d separately see Accessories page 17 Follow instructions included with the remote control OPERATING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING Keep ue open when operating unit WARNING If y...

Страница 11: ...thermocouple to cool When the thermocouple cools the appliance will shut down If pilot ame pattern is incorrect as shown in Figure 16 turn appliance off see To Turn Off Gas to Appliance page 10 see Tr...

Страница 12: ...ropane LPunits only propane LPgas supply may be low You may feel your gas pressure is too low If so contact your local propane LP or natural gas supplier TECHNICAL SERVICE You may have further questio...

Страница 13: ...as lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 External gas regulator setting is incorrect When ignitor button is pressed there is no spark at ODS pilot When...

Страница 14: ...n burner s see Cleaning and Maintenance page 12 1 Clean burner see Cleaning and Maintenance page 12 or replace burner ori ce 2 Replace damaged burner 3 Replace gas regulator 4 Correct external gas reg...

Страница 15: ...oved from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 6 4 Clean burners see Cleaning and Maintenance page 12 or replace bur...

Страница 16: ...nding while heating or contracting while cooling 1 Appliance burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply propane LP onl...

Страница 17: ...HAND HELD REMOTE CONTROL KIT HRC100 Allows the gas log heater to be turned on and off using a hand held remote control A wall mount docking station is included CLEANING KIT GCK Not Shown Your vented g...

Страница 18: ...www desatech com 114926 01C 18 ILLUSTRATED PARTS BREAKDOWN MODELS VTDMV24NA VTDMV24PA VTDMV18NA AND VTDMV18PA 1 2 3 4 5 6 17 16 15 7 8 9 10 11 12 14 13...

Страница 19: ...Pilot Assembly 1 103778 01 Pilot Assembly 1 11 111828 01 Brass Fitting 2 12 114930 01 Pilot Bracket 1 13 26205 Gas Ori ce 1 23109 Gas Ori ce 1 14 114930 01 Venturi 1 114936 01 Venturi 1 15 Burner 1 16...

Страница 20: ...The heater MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original conditi...

Отзывы: