Vanguard Firewerks VTDMV24NA Скачать руководство пользователя страница 1

Save this manual for future reference.

For more information, visit www.desatech.com

WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.

—  Do  not  store  or  use  gasoline  or  other  flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

—  Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

VENTED DECORATIVE GAS LOG HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

VTDMV24NA, VTDMV24PA, 

VTDMV18NA AND VTDMV18PA

Содержание Firewerks VTDMV24NA

Страница 1: ...ny other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s...

Страница 2: ...33 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This app...

Страница 3: ...be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Do not pla...

Страница 4: ...rovided by other means screens shall have openings for introduction of combustion air 8 Toreducethecreationofsoot followtheinstruc tions in Cleaning and Maintenance page 12 SAFETY INFORMATION Continue...

Страница 5: ...d ser vice person must install heater Follow all local codes WARNING Before installing in a solid fuel burning replace the chimney ue and rebox must be cleaned of soot creo sote ashes and loose paint...

Страница 6: ...nly in a solid fuel burning or UL127 factory built re place constructed of noncombustible material and connected to a working ue The replace chimney must have a permanent vent opening to outside with...

Страница 7: ...e control valve INSTALLATION Continued CAUTION Never connect propane LP unit directly to the propane LP supply This unit re quiresanexternalregulator not supplied Install the external regulator betwee...

Страница 8: ...om External Regulator 11 W C to 14 W C Pressure 3 Min Pipe Cap Tee Nipple Joint CHECKING GAS CONNECTIONS WARNING Testallgaspiping and connections internal and external to unit for leaks after installi...

Страница 9: ...valve 3 Make sure control knob of appliance is in the OFF position 4 Check all joints from equipment shutoff valve to gas control see Figure 9 or 10 Apply noncorrosive leak detection uid to all joint...

Страница 10: ...d separately see Accessories page 17 Follow instructions included with the remote control OPERATING APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING Keep ue open when operating unit WARNING If y...

Страница 11: ...thermocouple to cool When the thermocouple cools the appliance will shut down If pilot ame pattern is incorrect as shown in Figure 16 turn appliance off see To Turn Off Gas to Appliance page 10 see Tr...

Страница 12: ...ropane LPunits only propane LPgas supply may be low You may feel your gas pressure is too low If so contact your local propane LP or natural gas supplier TECHNICAL SERVICE You may have further questio...

Страница 13: ...as lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 External gas regulator setting is incorrect When ignitor button is pressed there is no spark at ODS pilot When...

Страница 14: ...n burner s see Cleaning and Maintenance page 12 1 Clean burner see Cleaning and Maintenance page 12 or replace burner ori ce 2 Replace damaged burner 3 Replace gas regulator 4 Correct external gas reg...

Страница 15: ...oved from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 6 4 Clean burners see Cleaning and Maintenance page 12 or replace bur...

Страница 16: ...nding while heating or contracting while cooling 1 Appliance burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply propane LP onl...

Страница 17: ...HAND HELD REMOTE CONTROL KIT HRC100 Allows the gas log heater to be turned on and off using a hand held remote control A wall mount docking station is included CLEANING KIT GCK Not Shown Your vented g...

Страница 18: ...www desatech com 114926 01C 18 ILLUSTRATED PARTS BREAKDOWN MODELS VTDMV24NA VTDMV24PA VTDMV18NA AND VTDMV18PA 1 2 3 4 5 6 17 16 15 7 8 9 10 11 12 14 13...

Страница 19: ...Pilot Assembly 1 103778 01 Pilot Assembly 1 11 111828 01 Brass Fitting 2 12 114930 01 Pilot Bracket 1 13 26205 Gas Ori ce 1 23109 Gas Ori ce 1 14 114930 01 Venturi 1 114936 01 Venturi 1 15 Burner 1 16...

Страница 20: ...The heater MUST be installed by a quali ed installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original conditi...

Отзывы: