Vanguard FBST Скачать руководство пользователя страница 4

www.desatech.com

105116-01D

4

12.  Do not use the firebox if it has been under water 

due to the shock hazard that could result with 

the blower accessary (if installed) in place. 

13.  Provide  adequate  clearances  around  air 

openings.

LOCaL CODES

Install and use firebox with care. Follow all local 

codes. In the absence of local codes, use the lat-

est edition of 

The National Fuel Gas Code ANS 

Z223.1

/

NFPA 54

*. Firebox must be electrically 

grounded in accordance with the 

National Electri-

cal Code, ANS/NFPA70 

(latest edition). 

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPaCkiNg

1.  Remove all protective packaging from inside 

firebox. Carefully lift the firebox off the bot

-

tom corrugated tray. 

2.  Carton  should  contain  2  deflective  hoods 

and hardware packet in addition to firebox 

assembly. If items are missing, inform dealer 

where you bought firebox. 

3.  Check all items for any shipping damage. If 

damaged, promptly inform dealer where you 

bought firebox.

NOTICE: The firebox identifica

-

tion label (including model num

-

ber,  serial  number,  clearances, 

etc.)  is  located  directly  above 

the brick liner and under the heat 

shield. See Figure 20, page 15.

PRODUCT FEaTURES

OpERATION

This firebox is designed for use with approved ANS 

Z21.11.2 decorative type unvented room heaters. 

(Physical size limitations apply. Refer to minimum 

firebox requirements supplied with log heater.) It 

requires no outside venting or chimney making in-

stallation easy and inexpensive. When used without 

the blower, the firebox requires no electricity mak

-

ing it ideal for emergency backup heat. 

PRODUCT 

SPECiFiCaTiONS

Figure 1 - Dual-Sided Firebox

1

/

4

"

5

/

8

"

5

12"

4"

1

/

4

"

1/2"

5/8"

20 

1

/

2

"

19 

1

/

2

"

1

/

2

"

1

/

4

"

40"

18 

1

/

2

"

1

/

8

"

36 

1

/

4

"

3

/

4

"

24"

36 

1

/

2

"

3" TYP.

42 

1

/

2

"

44 

1

/

4

"

1

/

4

"

5

/

8

"

5

12"

4"

1

/

4

"

1/2"

5/8"

20 

1

/

2

"

19 

1

/

2

"

1

/

2

"

1

/

4

"

40"

18 

1

/

2

"

1

/

8

"

36 

1

/

4

"

3

/

4

"

24"

36 

1

/

2

"

3" TYP.

42 

1

/

2

"

44 

1

/

4

"

BLOWER ACCESSORY 

The FBST firebox will accept the GA3500A ac

-

cessory. The variable blower allows you to select 

the fan speed you desire. The blower circulates 

heated air from the firebox into the room. Use of 

blower is optional.

BRICK LINER 

This firebox features a concrete brick liner. As 

with all concrete liners, this liner may develop 

slight cracks when exposed to heat. These cracks 

will not affect the performance of the firebox or 

vent-free gas logs. 

SaFETy iNFORMaTiON

Continued

Содержание FBST

Страница 1: ...ce WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the...

Страница 2: ...local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth...

Страница 3: ...een hood and brick liner in place Make sure these parts are in place and screens are closed before running firebox The supplied hoods may not be replaced with hoods which may be provided with a log he...

Страница 4: ...ng model num ber serial number clearances etc is located directly above thebricklinerandundertheheat shield See Figure 20 page 15 Product Features Operation This firebox is designed for use with appro...

Страница 5: ...to insure proper fresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction meth...

Страница 6: ...ating only if there are doorless passageways or ventilation grills between them AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH AIR FLOW FOR Firebox LOCATION Determining if You Have a C...

Страница 7: ...two perma nent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see option 1 Figure 3 You can also remove door into adjoining room see op tio...

Страница 8: ...cause mildew to form from too much moisture See Air for Combustion and Ventilation page 5 IMPORTANT Make sure the firebox is level If firebox is not level log set will not work properly Note Your Vang...

Страница 9: ...mes Wire mesh Screen Firebox Top Mantel Shelf 3 6 9 1 4 Combustible Material 1 1 2 Max Thickness Note All vertical measurements are from top of fireplace hood to bottom of mantel shelf These minimum c...

Страница 10: ...Wiring Firebox page 12 5 Carefully set firebox in front of rough open ing IMPORTANT If installing brass trim kit see instructions included with brass trim accessory You must install shoulder screws fr...

Страница 11: ...firebox enclosure where it can be accessed with a key through a wall as shown in Figure 13 Depending on the type of installation some local codes may require you to install two 2 manual shutoff valve...

Страница 12: ...orepressure testing gas piping Damage to gas valve may result and an un safe condition may be caused The appliance and its individual shutoff valve must be disconnected from the gas supply piping syst...

Страница 13: ...de door panel forward and up to remove tabs on panel from locating slots in firebox see Figure 16 3 Locatethetwostripsofhookandloopmounting strips on one side of the base of the lower com partment Ali...

Страница 14: ...th Blower Receptacle Hook and Loop Mounting Strips Control Knob Lock Nut Speed Control Shaft Figure 18 Installing Optional Blower GA3500A Operating Optional Blower GA3500A Light your gas appliance wit...

Страница 15: ...rners and circulating air passageways of the appliance be kept clean WARNING Children and adults should be alerted to the hazardsofhighsurfacetempera tures and to stay away to avoid burnsorclothingign...

Страница 16: ...Illustrated Parts Breakdown Model FBST These items are used on both sides of fireplace 8 14 16 16 16 7 1 7 2 2 16 11 16 12 6 6 6 15 15 15 15 13 13 10 5 15 15 15 15 6 6 15 15 4 15 15 15 15 15 15 15 4 1...

Страница 17: ...cer 4 5 26731 Deflector Hood 2 6 26740 Nailing Flange 8 7 1 02013 Side Refractory Brick Liner 2 7 2 02014 Bottom Refractory Brick Liner 2 8 24007 Side Refractory Retainer 4 9 12125 Screen 4 10 26752 E...

Страница 18: ...with the FBST fireboxes for bidirectional heat circula tion and may be installed during or after firebox installation Brass Trim GA6093 Easily clips around firebox to provide a finished appearance co...

Страница 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 20: ...ring a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND AL...

Отзывы: