Vanguard FBST Скачать руководство пользователя страница 15

www.desatech.com

105116-01D

15

OPERaTiNg gUiDELiNES 

aND MaiNTENaNCE 

iNSTRUCTiONS

When lit for the first time, a vent-free log heater will 

emit a slight odor for about an hour or two. This is 

a normal occurrence which is due to the “curing” 

of the logs and the “burn-in” of internal paints and 

lubricants used in the manufacturing process.

Keep control compartments, logs, burners and 

areas surrounding the logs clean by vacuuming or 

brushing at least twice a year. Temporary removal 

of the log set may ease the cleaning of the burner 

and pilot assembly. In cleaning, take care not to 

alter the settings on the pilot assembly. See the 

operating instructions supplied with your vent-free 

log heater for additional cleaning instructions.

 WARNING: Logs can be very 

hot!  Allow  logs  to  cool  before 

handling.

IMPORTANT: 

Turn off the gas supply at the exter

-

nal shutoff valve before servicing appliance. Any 

safety screen or guard removed for servicing must 

be replaced prior to operating the appliance.

Installation and repair should be done by a quali-

fied person. The appliance should be inspected 

before use and at least annually by a professional 

service person. More frequent cleaning may be 

required due to excessive lint from carpeting, pet 

hair, etc. It is imperative that the control compart-

ments, burners and circulating air passageways of 

the appliance be kept clean.

  WARNING:  Children  and 

adults should be alerted to the 

hazards of high surface tempera

-

tures and to stay away to avoid 

burns or clothing ignition. Young 

children  should  be  carefully 

supervised when they are in the 

same room as the appliance.

For lighting and operating this vent-free firebox, 

please refer to the vent-free gas logs manufactur-

er’s instruction manual.

REPLaCEMENT PaRTS

Note:

 Use only original replacement parts. This 

will protect your warranty  coverage for parts 

replaced under warranty. 

pARTS UNDER WARRANTY

Contact authorized dealers of this product. If they 

can’t supply original replacement part(s), call 

DESA at 1-866-672-6040.

When calling DESA, have ready

•  your name

•  your address

•  model and serial numbers of your firebox 

•  how firebox was malfunctioning

•  type of gas used (propane/LP or natural gas)

•  purchase date

Usually, we will ask you to return the defective 

part to the factory.

pARTS NOT UNDER WARRANTY

Contact authorized  dealers  of  this product. If 

they can’t supply original replacement part(s), 

call DESA at 1-866-672-6040 for referral infor

-

mation.

When calling DESA, have ready

•  model number of your firebox 

•  the replacement part number

Note:

 The firebox identification label (including 

model number, serial number, clearances, etc.) is 

located above the brick liner and under the heat 

shield. See Figure 20.

Figure 20 - Location of Firebox 

Identification Label

Air Deflector

Identification Label

Brick Liner

Heat Shield

Содержание FBST

Страница 1: ...ce WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the...

Страница 2: ...local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth...

Страница 3: ...een hood and brick liner in place Make sure these parts are in place and screens are closed before running firebox The supplied hoods may not be replaced with hoods which may be provided with a log he...

Страница 4: ...ng model num ber serial number clearances etc is located directly above thebricklinerandundertheheat shield See Figure 20 page 15 Product Features Operation This firebox is designed for use with appro...

Страница 5: ...to insure proper fresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction meth...

Страница 6: ...ating only if there are doorless passageways or ventilation grills between them AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH AIR FLOW FOR Firebox LOCATION Determining if You Have a C...

Страница 7: ...two perma nent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see option 1 Figure 3 You can also remove door into adjoining room see op tio...

Страница 8: ...cause mildew to form from too much moisture See Air for Combustion and Ventilation page 5 IMPORTANT Make sure the firebox is level If firebox is not level log set will not work properly Note Your Vang...

Страница 9: ...mes Wire mesh Screen Firebox Top Mantel Shelf 3 6 9 1 4 Combustible Material 1 1 2 Max Thickness Note All vertical measurements are from top of fireplace hood to bottom of mantel shelf These minimum c...

Страница 10: ...Wiring Firebox page 12 5 Carefully set firebox in front of rough open ing IMPORTANT If installing brass trim kit see instructions included with brass trim accessory You must install shoulder screws fr...

Страница 11: ...firebox enclosure where it can be accessed with a key through a wall as shown in Figure 13 Depending on the type of installation some local codes may require you to install two 2 manual shutoff valve...

Страница 12: ...orepressure testing gas piping Damage to gas valve may result and an un safe condition may be caused The appliance and its individual shutoff valve must be disconnected from the gas supply piping syst...

Страница 13: ...de door panel forward and up to remove tabs on panel from locating slots in firebox see Figure 16 3 Locatethetwostripsofhookandloopmounting strips on one side of the base of the lower com partment Ali...

Страница 14: ...th Blower Receptacle Hook and Loop Mounting Strips Control Knob Lock Nut Speed Control Shaft Figure 18 Installing Optional Blower GA3500A Operating Optional Blower GA3500A Light your gas appliance wit...

Страница 15: ...rners and circulating air passageways of the appliance be kept clean WARNING Children and adults should be alerted to the hazardsofhighsurfacetempera tures and to stay away to avoid burnsorclothingign...

Страница 16: ...Illustrated Parts Breakdown Model FBST These items are used on both sides of fireplace 8 14 16 16 16 7 1 7 2 2 16 11 16 12 6 6 6 15 15 15 15 13 13 10 5 15 15 15 15 6 6 15 15 4 15 15 15 15 15 15 15 4 1...

Страница 17: ...cer 4 5 26731 Deflector Hood 2 6 26740 Nailing Flange 8 7 1 02013 Side Refractory Brick Liner 2 7 2 02014 Bottom Refractory Brick Liner 2 8 24007 Side Refractory Retainer 4 9 12125 Screen 4 10 26752 E...

Страница 18: ...with the FBST fireboxes for bidirectional heat circula tion and may be installed during or after firebox installation Brass Trim GA6093 Easily clips around firebox to provide a finished appearance co...

Страница 19: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 20: ...ring a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND AL...

Отзывы: