    WARNING

Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death.

!

CAUTION

Identifies an instruction which, if not followed, may severely damage the unit and/or its components.

ABOUT THIS MANUAL

Because of the large amount of models covered by this publication, the illustrations are typical ones. Some details of your unit may be 
slightly different than the ones shown.
Please take note that this manual uses the following symbols to emphasize particular information:

NOTE: Indicates supplementary information needed to fully complete an instruction.

We welcome any suggestions you may have concerning this manual or the unit, and we would appreciate hearing your comments on ways 
to better serve you. Please contact us by phone at 1-800-567-3855.

ABOUT THESE UNITS
LIMITATION

For residential (domestic) installation only. Installation work and electrical wiring must be done by a qualified person(s) in accordance with 
all applicable codes and standards, including fire-rated construction codes and standards.

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING:
1.

  Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or 

telephone number listed in the warranty.

2.

  Before servicing or cleaning the unit, disconnect power cord from electrical outlet.

3.

  This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.

4.

  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

5.

  Do not use this unit with any solid-state speed control device other than following wall controls: 

6.

  This unit must be grounded. The power supply cord has a 3-prong grounding plug for your personal safety. It must be plugged into a 

mating 3-prong grounding receptacle, grounded in accordance with the national electrical code and local codes and ordinances. Do 
not remove the ground prong. Do not use an extension cord.

7.

  Do not install in a cooking area or connect directly to any appliances.

8.

  Do not use to exhaust hazardous or explosive materials and vapors.

9.

  When performing installation, servicing or cleaning these units, it is recommended to wear safety glasses and gloves.

10.

 Due to the weight of the unit, two installers are recommended to perform installation.

11.

 When applicable local regulation comprise more restrictive installation and/or certification requirements, the aforementioned 

requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.

CAUTION

1.

  To avoid prematurate clogged filters, turn OFF the unit during construction or renovation.

2.

  Please read specification label on product for further information and requirements.

3.

  Be sure to duct air outside – Do not intake/exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage. 

4.

  Intended for residential installation only in accordance with the requirements of NFPA 90B (for a unit installed in U.S.A.) or Part 9 of the 

National Building Code of Canada (for a unit installed in Canada).

5.

  Do not run any air ducts directly above or closer than 2 ft (0.61 m) to any furnace or its supply plenum, boiler, or other heat producing 

appliance. If a duct has to be connected to the furnace return plenum, it must be connected not closer than 9’ 10” (3 m) from this plenum 
connection to the furnace. 

6.

  The ductwork is intended to be installed in compliance with all local and national codes that are applicable.

7.

  When leaving the house for a long period of time (more than two weeks), a responsible person should regularly check if the unit 

operates adequately.

8.

  If the ductwork passes through an unconditioned space (e.g.: attic), the unit must operate continuously except when performing 

maintenance and/or repair. Also, the ambient temperature of the house should never drop below 18°C (65°F).

WARNING

U

NIT

M

AIN

 C

ONTROL

A

UXILIARY

 C

ONTROLS

V

ENMAR

 AVS C

ONSTRUCTO

 1.2 ERV

A

LTITUDE

, D

ECO

-T

OUCH

, L

ITE

-T

OUCH

 C

ONSTRUCTO

,

S

IMPLE

-T

OUCH

 C

ONSTRUCTO

 

OR

 C

ONSTRUCTO

D

EHUMIDISTAT

20-

MINUTE

 

LIGHTED

 

PUSH

-

BUTTON

 

TIMER

AND

 60-

MINUTE

 

CRANK

 

TIMER

VÄN

EE 60H+ ERV

P

LATINUM

, D

ECO

-T

OUCH

, L

ITE

-T

OUCH

 B

RONZE

S

IMPLE

-T

OUCH

 B

RONZE

 

OR

 B

RONZE

 

Содержание Venmar AVS 41553

Страница 1: ...ERGY STAR requirements only when used in Canada 21784 rev 01 INSTALLATION GUIDE FOR VENMAR AVS UNITS CONSTRUCTO 1 2 ERV AND V NEE 60H ERV Model no 41556 ERV with top ports Model no 41554 ERV with side...

Страница 2: ...sion cord 7 Do not install in a cooking area or connect directly to any appliances 8 Do not use to exhaust hazardous or explosive materials and vapors 9 When performing installation servicing or clean...

Страница 3: ...NSTALLING 2 EXTERIOR HOODS 10 2 9 INSTALLING THE TANDEM TRANSITION KIT 10 3 CONTROLS 11 13 3 1 INTEGRATED CONTROL 11 3 2 ELECTRICAL CONNECTION TO OPTIONAL WALL CONTROLS 12 13 3 2 1 ELECTRICAL CONNECTI...

Страница 4: ...in the lowest liveable level Homes with more than one level require at least one exhaust register at the highest level See figure at right 1 2 CENTRAL DRAW POINT CONNECTION TO A FORCED AIR SYSTEM Stal...

Страница 5: ...H0102 2 INSTALLATION 2 1 INSPECT THE CONTENTS OF THE BOX Inspect the exterior of the unit for shipping damage Ensure that there is no damage to the door door latches power cord etc Remove and discard...

Страница 6: ...rew them from the unit Install the latches on their new locations VD0176 Latches on sides of the unit Latches in front of the unit VB0094 VO0089 VO0090 2 4 HOW TO HANG THE UNIT Hang the unit with the...

Страница 7: ...a register must be floor installed direct the airflow up the wall 2 6 2 CENTRAL DRAW POINT SYSTEM AS ILLUSTRATED IN SECTION 1 2 Stale air exhaust ductwork Same as for Fully Ducted System described on...

Страница 8: ...tions to the furnace air handler NOTE For Method 1 it is not essential to synchronize the furnace blower operation with the unit operation but we recommend it WARNING When performing duct connections...

Страница 9: ...of the double collar then pull down the vapor barrier shaded part in illustrations below over the insulation and over the outer ring of double collar Apply duct tape to the joint making an airtight se...

Страница 10: ...e grill Any exhaust from a combustion source Garbage bin and any other source of contamination VD0028 EXHAUST HOOD INTAKE HOOD TAPE AND DUCT TIE 18 457 MM 6 1 8 M 18 457 MM 18 457 MM 6 1 8 M 6 152 MM...

Страница 11: ...control If a problem occurs during the unit operation its integrated control LED 2 will blink The color of the blinking light depends on the type of error detected Refer to Section 8 TROUBLESHOOTING o...

Страница 12: ...between themselves or by touching any other components on the wall control Avoid poor wiring connections To reduce electrical interference noise potential do not run wall control wiring next to contro...

Страница 13: ...Amber light LOW speed Green ligh HIGH speed Blinking light See User Manual Sans lumi re Arr t ou contr l par contr le mural Lumi re ambre Basse vitesse Lumi re verte Haute vitesse Clignotant Voir guid...

Страница 14: ...2 9 5 V class 2 120 V neutral J9 1 J9 2 J9 3 J4 2 J9 4 Exhaust fan motor capacitor Supply fan motor capacitor J8 1 J8 2 J8 4 J8 5 K4 J12 2 J12 1 A1 Damper motor J3 2 J3 1 J2 2 J2 1 F1 J12 5 J12 4 J12...

Страница 15: ...running in defrost while balancing By waiting 10 minutes after plugging the unit in you are assured that the unit is not in a defrost cycle 2 Place the magnehelic gauge on a level surface and adjust i...

Страница 16: ...ommends to contact a certified service depot for all replacement parts and repairs NO DESCRIPTION PART NO 41554 ERV SIDE PORTS 41556 ERV TOP PORTS 41654 ERV SIDE PORTS 41656 ERV TOP PORTS 1 OVAL PORT...

Страница 17: ...l is set The shortest delay is obtained when the wall control is set on MIN or MAX in VENT Mode Ensure the RED wire is not damaged and properly connected 3 Altitude Platinum or Deco Touch wall control...

Страница 18: ...rk but exhaust motor works The supply motor may be defective The supply motor capacitor or the PCB may be defective Plug supply motor to J5 connector and exhaust motor to J4 connector If the integrate...

Отзывы: