background image

6

3. Maintenance

 (cont’d)

3.2 Annual Maintenance

Do the same operations as the Quarterly Maintenance (Section 3.1), and clean the 
recovery core as follows (refer to the core label):

HRV units

: Soak the heat recovery core in a mixture of lukewarm water and mild soap. 

Rinse thoroughly. Shake the core to remove excess water and let it dry.

ERV units

: Remove the dust on the core using a vacuum cleaner and a soft brush 

attachment.

After reinstalling the core, the filters and the unit’s door, then clean the exterior hoods.

If the problem is still not solved, call your installer or the nearest approved Service Center. 
You can also reach the Customer Service Department at the following phone number: 
1-800-567-3855.

P

ROBLEM

T

RY

 

THIS

...

1. Nothing 

works.

• See if the unit is plugged in.
• See if the unit is receiving power from the house 

circuit breaker or fuse.

2.  Condensation on windows (air too 

humid).

• Operate the unit on maximum speed ventilation

until the situation is corrected.

• Leave curtains half-open to allow air circulation.
• Store all firewood in a closed room with a dehumidifier 

or in a well ventilated room, or store the wood outside.

• Do not adjust the thermostat of your heating system 

below 18°C (64°F).

3. Indoor air too dry.

• Temporarily use a humidifier.
•  Operate the unit in recirculation mode (if available).

4.  Air too cold at the air supply grille.

• Check if the exterior hood is blocked.
•  Operate the unit in low speed ventilation, in intermittent

or in recirculation mode (if available).

•  Install a duct heater.

5.  The LED of the integrated control is 

blinking green.

• There is a problem with the thermistor. The unit is still 

working, but will defrost frequently. 

  Contact your installer.

6.  The LED of the integrated control is 

blinking amber.

• There is a problem with the motorized damper. The 

unit is OFF. For a 2½-hour period, the unit will try to 
reset the damper every 30 minutes. After 2½ hours, 
if the problem is not solved, the unit stops trying to 
reset damper.

• Contact your installer.

7.  The integrated control push button 

does not work.

• The 30-second boot sequence is not completed.
• See 

Integrated Control 

on page 4.

4. Troubleshooting

If the unit does not work properly, reset the unit by unplugging it for one minute and then 
replug it. If it is still not working properly, refer to table below. First make sure that the 
integrated control is set to OFF (no LED lit).

For wall controls problems, refer to the Troubleshooting section in the

 Main and 

auxiliary wall controls user guide 

(included with the ventilation unit and also available at 

www.vanee.ca).

Содержание 40E 44262

Страница 1: ...RESOURCES CANADA AND THE US EPA THEY MEET ENERGY STAR REQUIREMENTS ONLY WHEN USED IN CANADA READ AND SAVE THESE INSTRUCTIONS User Guide 40E 40H AND 50H VB0200 VB0200 VB0201 VB0201 40E MODEL NO 44262 TOP PORTS SIDE PORTS 40E MODEL NO 44263 40H MODEL NO 44252 50H MODEL NO 44600 40H MODEL NO 44253 50H MODEL NO 44602 ...

Страница 2: ...not use your unit during construction or renovation of your house or when sanding drywall This type of dust may damage your system Since the electronic control system of the unit uses a microprocessor it may not operate correctly because of external noise or very short power failure If this happens unplug the unit and wait approximately 10 seconds Then plug the unit in again CAUTION CAUTION NOTE I...

Страница 3: ...e unit shifts to maximum speed and the dampers close After defrosting the unit returns to the operating mode selected by the user REPLACEMENT PARTS AND REPAIR In order to ensure your ventilation unit remains in good working condition you must use vänEE genuine replacement parts only vänEE genuine replacement parts are specially designed for each unit and are manufactured to comply with all the app...

Страница 4: ...to table below LED COLOR RESULTS AMBER Unit is on Low speed GREEN Unit is on High speed NO LIGHT Unit is OFF or controlled by a main control Ifaproblemoccursduringtheunitoperation itsintegrated control LED 2 will blink The color of the blinking light depends on the type of error detected Refer to Section 4 Troubleshooting on last page for further details CAUTION When using optional main control th...

Страница 5: ...or 3 VO0191 A B 1 2 3 3 Slide out both filters 1 and recovery core 2 from the unit 4 Clean the inside walls of the unit with a clean damp cloth then wipe with a clean dry one 5 Remove dust on filters and on core using a vacuum cleaner and a soft brush attachment 6 Wash both core filters under lukewarm water with mild soap Rinse thoroughly and let dry completely before reinstalling on the core 7 Sl...

Страница 6: ...of your heating system below 18 C 64 F 3 Indoor air too dry Temporarily use a humidifier Operate the unit in recirculation mode if available 4 Air too cold at the air supply grille Check if the exterior hood is blocked Operate the unit in low speed ventilation in intermittent or in recirculation mode if available Install a duct heater 5 The LED of the integrated control is blinking green There is ...

Отзывы: