background image

5

3. Maintenance

Risk of electric shock. Before performing any maintenance or servicing, always 
disconnect the unit from its power source. 
Sharp edges may be present. When cleaning the unit, it is recommended to wear 
safety glasses and gloves.

3.1 Quarterly Maintenance

WARNING

!

VD0244

1

2

1) Core 

 

2) Core filters

Refer to illustration at right to identify the inner parts of 
your unit.

1.  Unplug the unit.

2.  Remove the unit door by following 
 these 

steps:

 

A.  Remove both door bottom machine

 

screws no. 8-32 x 1” (

1

) and set 

 aside.
 B. 

Open 

(

2

) and lift out the door (

3

).

VO0191

A

B

1

2

3

3.  Slide out both filters (

1

) and recovery core (

2

 

from the unit.

4.  Clean the inside walls of the unit with a clean 
 

damp cloth, then wipe with a clean dry one. 

5.  Remove dust on filters and on core using a 
 

vacuum cleaner and a soft brush attachment.

6.  Wash both core filters under lukewarm water 
  with mild soap. Rinse thoroughly and let dry 
 

completely before reinstalling on the core.

7.  Slide the core and the cleaned filters into the unit.

8.  Reinstall the door. Secure it with both mechanical screws no. 8-32 x 1” previously 
 

removed and plug the unit.

  NOTE:   The unit will return to its previous setting after a 30-second delay for boot
  

sequence.

VD0243

1

2

CAUTION

Follow the instructions on the core label to 
reinstall it correctly.

Содержание 40E 44262

Страница 1: ...RESOURCES CANADA AND THE US EPA THEY MEET ENERGY STAR REQUIREMENTS ONLY WHEN USED IN CANADA READ AND SAVE THESE INSTRUCTIONS User Guide 40E 40H AND 50H VB0200 VB0200 VB0201 VB0201 40E MODEL NO 44262 TOP PORTS SIDE PORTS 40E MODEL NO 44263 40H MODEL NO 44252 50H MODEL NO 44600 40H MODEL NO 44253 50H MODEL NO 44602 ...

Страница 2: ...not use your unit during construction or renovation of your house or when sanding drywall This type of dust may damage your system Since the electronic control system of the unit uses a microprocessor it may not operate correctly because of external noise or very short power failure If this happens unplug the unit and wait approximately 10 seconds Then plug the unit in again CAUTION CAUTION NOTE I...

Страница 3: ...e unit shifts to maximum speed and the dampers close After defrosting the unit returns to the operating mode selected by the user REPLACEMENT PARTS AND REPAIR In order to ensure your ventilation unit remains in good working condition you must use vänEE genuine replacement parts only vänEE genuine replacement parts are specially designed for each unit and are manufactured to comply with all the app...

Страница 4: ...to table below LED COLOR RESULTS AMBER Unit is on Low speed GREEN Unit is on High speed NO LIGHT Unit is OFF or controlled by a main control Ifaproblemoccursduringtheunitoperation itsintegrated control LED 2 will blink The color of the blinking light depends on the type of error detected Refer to Section 4 Troubleshooting on last page for further details CAUTION When using optional main control th...

Страница 5: ...or 3 VO0191 A B 1 2 3 3 Slide out both filters 1 and recovery core 2 from the unit 4 Clean the inside walls of the unit with a clean damp cloth then wipe with a clean dry one 5 Remove dust on filters and on core using a vacuum cleaner and a soft brush attachment 6 Wash both core filters under lukewarm water with mild soap Rinse thoroughly and let dry completely before reinstalling on the core 7 Sl...

Страница 6: ...of your heating system below 18 C 64 F 3 Indoor air too dry Temporarily use a humidifier Operate the unit in recirculation mode if available 4 Air too cold at the air supply grille Check if the exterior hood is blocked Operate the unit in low speed ventilation in intermittent or in recirculation mode if available Install a duct heater 5 The LED of the integrated control is blinking green There is ...