background image

11

A

DJUSTING

 DEHUMIDISTAT

Setting during the summer months:

During this period, unless being afflicted with breathing problems, using the
Dehumidistat is unnecessary. Set the slide switch to «OFF». (Do not
exchange in day time; exchange at night time, if cool outside, or if it is not raining.)

Setting during the fall, winter and spring months:

(When severe condensation appears on windows)

1)

Determine the humidity level in your house (bring the knob (

B

counterclockwise to its maximum position, then bring it back clockwise
slowly until you hear a «click»).

2)

Set the knob to one line under this temperature level or «click».

It is possible (and normal) to experience condensation on your 
windows when drastic changes in temperature happen (for example: 
-5°C [23°F] to -20°C [-4°F]). In that case, we suggest waiting a few days
to allow the situation to stabilize.

CAUTION

Do not select a temperature below -20°C (-4°F). This could lead to 
excessive dryness in the air causing discomfort for the occupants.

2.2 Main Controls 

(cont’d)

2. Controls

(cont’d)

2.2.3 Bronze Main Control (90H-V only)

A

DJUSTING

 AIR SUPPLY CONTROL

1)

Select 

speed «MIN» or «MAX»

using slide switch (

A

).

• When «MIN» (minimum speed)

is selected, if the knob (

B

) is set

above the click, the unit will
exchange in low speed with the
outside and if it is set below the
click, the unit will exchange 
on high speed with the outside
until the desired humidity level
has been reached.

• When «MAX» (maximum speed)

is selected, the unit will exchange on high speed with the outside
either if the knob is set below or above the click.

2)

To 

turn off the unit

, slide the switch at the 

«OFF»

position.

COM

FORT

Z O N

E

O

FF

%

REL

ATIVE HUM IDI

TY

70%

60%

50%

40%

30%

25%

20%

HUMIDITY
CONTROL

DURING FALL, WINTER 
AND SPRING, SET THE 

DIAL ACCORDING TO 

THE DESIRED MAXIMUM 

INDOOR HUMIDITY LEVEL. 

DURING SUMMER SET 

THE DIAL TO THE 

OFF POSITION. 

VC00

3

9

MIN.

MAX.

OFF

MO

RE HUMID

LE

SS

HUMID

C

O

M

F

O

R

T

Z

O

N

E

-

3

0

°

C

-22

°

F

-20

°

C

-4

°

F

-5

°

C

2

3

°

F

5

°

C+

41

°

F+

A

B

Содержание 1601605

Страница 1: ...User Guide PLEASE READ AND SAVE THESE INSTRUCTIONS HEAT RECOVERY VENTILATORS HRV 90H V ECM 90H V AND 60H NOVO MODELS 08373 rev A Model no 43905 VB0124 Model no 1601630 VB0125 Model no 1601605 VB0127...

Страница 2: ...indicated on the product registration card included with this guide WARNING Identifies an instruction which if not followed might cause serious personal injuries including possibility of death CAUTIO...

Страница 3: ...ontrol 90H V only 10 2 2 3 Bronze Main Control 90H V only 11 2 3 OPTIONAL AUXILIARY CONTROLS 12 13 2 3 1 20 40 60 minute Push Button Timer HRV 90H V ECM 60H Novo 12 2 3 2 20 minute Light Push Button 9...

Страница 4: ...ection 4 Troubleshooting on last page for further details PRESS ON PUSH BUTTON LED COLOR RESULTS ONCE AMBER UNIT IS ON LOW SPEED TWICE GREEN UNIT IS ON HIGH SPEED THREE TIMES NO LIGHT UNIT IS OFF When...

Страница 5: ...amper position completely set the RED light turns off and the booting sequence is done NOTE No command will be taken until the unit is fully booted BOOT SEQUENCE HRV 90H V ECM ONLY The unit boot seque...

Страница 6: ...lation or air exchange Periods of the day morning day evening and night Week days Week end days Hour display AM or PM display Appears only when setting backlight preferences Ventilation Recirculation...

Страница 7: ...alues D Mode Pref key Mode Selects whether Ventilation Recirculation or Program mode pref Push 3 seconds to access Preference settings E Reset filter keys Press on B and D keys simultaneously for 5 se...

Страница 8: ...FRI SAT SUN MON HOUR DISPLAY 12 00 OR 24 00 12 00 CURRENT HOUR FROM 0 TO 12 OR 24 12 CURRENT MINUTE FROM 00 TO 59 00 TEMPERATURE UNIT C OR F C INSIDE TEMPERATURE ON OR OFF ON DISPLAY MINIMUM OUTSIDE...

Страница 9: ...o select the period starting hour NOTE Time changes by 15 minutes increments Press SET key B to confirm and go to select the ventilation speed or type will flash on screen Use to select the ventilatio...

Страница 10: ...FROM THE HOUSE FOR A FEW DAYS ALSO WHEN YOU DEEM THE INSIDE AIR IS TOO DRY IN HEATING SEASON OR TOO HUMID DURING COOLING SEASON IN THIS MODE THE UNIT IS OFF FOR 40 MINUTES PER HOUR AND VENTILATES AT M...

Страница 11: ...mperature below 20 C 4 F This could lead to excessive dryness in the air causing discomfort for the occupants 2 2 Main Controls cont d 2 Controls cont d 2 2 3 Bronze Main Control 90H V only ADJUSTING...

Страница 12: ...there is temporary humidity excess or pollutants Purpose To eliminate excess humidity produced by showers or other periodic activities producing pollutants Within 2 seconds push one time for 20 minute...

Страница 13: ...30 25 20 HUMIDITY CONTROL DURING FALL WINTER AND SPRING SET THE DIALACCORDING TO THE DESIRED MAXIMUM INDOOR HUMIDITY LEVEL DURING SUMMER SET THE DIAL TO THE OFF POSITION VC0038 CAUTION Do not select...

Страница 14: ...maintenance or servicing always disconnect the unit from its power source When cleaning the unit it is recommended to wear safety glasses and gloves 3 1 Semi Annual Maintenance VD0005 3 Maintenance 2...

Страница 15: ...ft brush attachment VD0208 8 Slide in the cleaned core into the unit see illustration beside 9 Slide in the cleaned filters into the unit NOTE For HRV 90H V ECM only blue side of filters must be on to...

Страница 16: ...e Check if the exterior hood is not blocked See Controls Section on page 4 to 13 Install a duct heater 7 The LED of the integrated control is blinking red a HRV 90H V ECM only There is a problem with...

Отзывы: