Installation Instructions
08.02.2016
5
Assembly and installation
The following cables are recommended for connection to the intrusion detection control unit and seismic detec-
tors:
From control panel to key module
I-Y(St)Y 4 x 2 x 0.6mm
From indicator module to seismic detector
I-Y(St)Y 2 x 2 x 0.6mm
Cable between modules
1 x Ribbon cable 1 x 4 x AWG26
1 x Ribbon cable 1 x 5 x AWG26
The remote testing system contains components that are susceptible to electrical discharge. Always
eliminate electrostatic charge before touching these components.
Only connect plug and cable joints when the system is switched off and free of any supply voltage.
5.1
Figure 1: Connections with housing open
A
Key module
B
Indicator module
C
Intruder alarm system
D
Connection cable to intruder alarm sys-
tem
E
Connection cable to indicator module
F
Mounting aid as mechanical connection
between modules
G
Connection cable to seismic detector
H
Seismic detector
I
Mounting screws
5.2
Assembly guidelines
1. The system must be assembled by a suitably trained person and all country-specific requirements must be
observed.
2. Assemble the system on a hard, level surface.
3. When positioning, ensure the necessary space and note the wiring arrangement. Each module must be se-
cured with two screws (Fig. 1, Item I).
4. Modules should preferably be joined together on the long side. Use the mounting aid (Fig.1, item F) for this
purpose. If modules are to be connected on the short side, at least two pairs of modules should be con-
nected next to one another on this side.