Configuration: Set HDCP Compliance status for every input, and manage EDID. See the screenshot below:

If there is any modification, press Save to restore the settings, or press Cancel to withdraw.
Interface: Set title bar label and button labels, press Save to save the settings

Network: Inquire and configure network settings including MAC address, IP address, subnet mask, and Gateway

Note: Log in as user access main interface only.

Содержание 4x3 HDBaseT

Страница 1: ...4x3 HDBaseT Matrix Selector Switch with Additional HDMI Output Vanco Part Number HDBT4X3 Technical Support www vanco1 com techsupport vanco1 com 800 626 6445 ...

Страница 2: ...cularly at the plugs 9 Use unit only with accessories specified by the manufacturer 10 Refer all servicing to qualified personnel CAUTION HDMI is a very complex technology requiring continuous authentication of the signal and the same video resolution and audio settings on all electronic equipment in the system When there are multiple sources and displays the video resolution and audio setting on ...

Страница 3: ...nstall kit includes 3 HDBaseT PoC receivers 4 IR Emitter and Receiver sets and IR remote control Supports HDCP 2 2 and is backwards compatible with previous version of HDCP and HDMI Transmits 4Kx2K 60Hz 4 2 0 up to 26 ft 8m via HDMI port and 131 ft 40m via HDBaseT port 3 HDBaseT outputs with distances up to 230 ft 70m at 1080p and 131 ft 40m at 4Kx2K on a single Cat5e 6 cable HDBaseT Receivers are...

Страница 4: ...Dolby DTS DTS HD Frequency Response 20Hz 20KHz Output Connector 1 L R RCA 1 SPDIF Control Ports 4 IR OUT 3 IR IN 1 IR EYE 1 TCP IP female RJ45 1 RS232 3 pin pluggable terminal block Panel Control Front panel buttons RS232 Control 3 pin pluggable terminal block IR Extended IR receiver TCP IP Control Web based GUI Power Supply Input 100 240V 50 60Hz Output DC 24V 2 71A Power Consumption 35W Max Temp...

Страница 5: ... 10 HDMI Output Connect an HDMI cable from the Matrix Switcher to the displayer 11 SPDIF Output Digital audio output connects directly via an optic fibre cable to the Toslink input on a sound bar 12 RCA L R Output PCM Analogue audio output sockets connect the de embedded audio additional speakers 13 Control TCP IP RJ45 port Connect with PC for Web based GUI control RS232 Serial port for unit contr...

Страница 6: ...n the IR Emitters to the IR OUT sockets 1 4 on Matrix Switcher to make up as IR Matrix 8 Plug the phoenix connector in to the RS232 socket on the matrix this will enable the Matrix Switcher to be controlled via a PC 9 Plug in a Patch lead from the router in to the Ethernet port on Matrix Switcher to control Matrix Switcher by TCP IP protocol 10 Plug in the Power supply adapter 24V DC and tighten t...

Страница 7: ...ely 3 Control the Matrix Switcher locally remotely Switching I O connection 1 To convert one input to an output Example Input 1 to Output 3 Press INPUTS 1 OUTPUTS 3 ENTER NOTE Default status on first boot up this matrix assigns the IR outputs to the corresponding HDMI input meaning IR out 1 is directly associated to HDMI input 1 and so on When you switch an HDMI input to a different output the cor...

Страница 8: ...rred to IR OUT port of the Matrix Switcher If the IR receiver connected to HDBaseT receiver or the Matrix Switcher is without an IR carrier signal send the command 0901 to enter infrared carrier enforcing mode and then IR signal can be transferred to IR OUT port Control Far end Device Locally Connect an IR receiver to IR IN on the Matrix Switcher and use the IR Remote of far end device to control ...

Страница 9: ...ports and the 3 IR IN ports on the far end receivers make up a 4x3 IR matrix See as below The IR signal is sent by IR remote then it is transferred to HDBaseT receiver then to corresponding zone of the matrix through the twisted pair finally it is transferred to IR OUT port and received by controlled device Switching Operation Sending command reference to RS232 Control x1 R x2 x1 Corresponding to ...

Страница 10: ...e control software files in corresponding file path Basic Settings First connect the Matrix Switcher with an input device and an output device Then connect it with a computer which is installed with RS232 control software Double click the software icon to run this software Here we take the software CommWatch exe as example The icon is showed as below The interface of the control software is showed...

Страница 11: ... network segment to the same as the Matrix Switcher s See right Controlled by PC s in LAN Connect the Matrix Switcher a router and several PCs to setup a LAN as shown in the following figure Set the network segment of the Matrix Switcher to the same as the router s then PCs within the LAN are able to control the Matrix Switcher Follow these steps to connect the devices Step1 Connect the TCP IP por...

Страница 12: ...as admin can access more configuration interfaces than user Enter username and the right password Here is a brief introduction to the interfaces Main Interface shown after logging in provide intuitive I O connection switching See the screenshot below The button matrix displays every possible connection between every input and output users can carry on the connections by clicking corresponding butt...

Страница 13: ...there is any modification press Save to restore the settings or press Cancel to withdraw Interface Set title bar label and button labels press Save to save the settings Network Inquire and configure network settings including MAC address IP address subnet mask and Gateway Note Log in as user access main interface only ...

Страница 14: ...e the username and password the same as the GUI log in settings modified password will be available only after rebooting to log in the configuration interface After that click Administration at the source menu to get to Upload Program as shown below Select the desired update file and press Apply it will start upgrading ...

Страница 15: ...ile bin to PC Step2 Connect the USB ports of the Matrix Switcher and the PC via USB cable Step3 Double click the update software icon see as below FIRMWARE UPDATE It will enter the upgrade interface shown as below Step4 Click Connect USB Step5 Click Open to load the upgrade file then click Updata to start firmware upgrading Note To ensure available control the COM number of the PC should be 1 9 ...

Страница 16: ...CAUSE The IR receiver connected to IR IN port is not with carrier SOLUTION Change for an IR receiver with carrier 10 PROBLEM Power Indicator remains off when powered on CAUSE Failure in power connection SOLUTION Check whether the cables are connected correctly 11 PROBLEM EDID management does not work normally CAUSE The HDMI cable is broken at the output end SOLUTION Change for another HDMI cable w...

Страница 17: ...isk of damage to the unit Follow all instructions and warnings marked on this unit Do not attempt to service this unit yourself except where explained in this manual Provide proper ventilation and air circulation and do not use near water Keep objects that might damage the device and assure that the placement of this unit is on a stable surface Use only the power adapter and power cords and connec...

Страница 18: ...ninterruptible power supply must be installed in the electrical circuit to protect against power surges If repairs are needed during the warranty period the purchaser will be required to provide a sales receipt sales invoice or other acceptable proof of purchase to the seller of this equipment The seller will then contact Vanco regarding warranty repair or replacement LIABILITY STATEMENT Every eff...

Страница 19: ...Instruction Manual prior to calling or installing this unit since it will familiarize you with the capabilities of this product and its proper installation All active electronic products are 100 inspected and tested to insure highest product quality and trouble free installation and operation The testing process utilizes the types of high definition sources and displays typically installed for ent...

Страница 20: ...Vanco International 506 Kingsland Drive Batavia Illinois 60510 call 800 626 6445 fax 630 879 9189 visit www vanco1 com ...

Отзывы: