background image

PAGE 12

PRINTED IN THE U.S.A.

DISCHARGE AIR USED FOR
BREATHING WILL CAUSE SEVERE
INJURY OR DEATH.  CONSULT
FILTRATION SPECIALIST FOR
ADDITIONAL FILTRATIONS AND
TREATMENT EQUIPMENT TO
MEET HEALTH AND SAFETY
REGULATIONS.

DANGER

AIR AND OIL UNDER PRESSURE
WILL CAUSE SEVERE
PERSONAL INJURY OR DEATH.
SHUT DOWN COMPRESSOR AND
RELIEVE SYSTEM OF ALL
PRESSURE BEFORE REMOVING
VALVES, CAPS, PLUGS,
FITTINGS, BOLTS AND FILTER.

DANGER

ELECTRICAL SHOCK FROM
IMPROPER GROUNDING CAN
CAUSE INJURY OR DEATH.

GROUND UNIT AND RELATED
EQUIPMENT ACCORDING TO
NATIONAL ELECTRICAL CODE
AND LOCAL REGULATIONS.

WARNING

WARNING

READ THE OPERATOR'S
MANUAL BEFORE STARTING
THIS UNIT.  FAILURE TO ADHERE
TO INSTRUCTIONS CAN RESULT
IN SEVERE PERSONAL INJURY
OR DEATH.  REPLACEMENT
MANUALS CAN BE
PURCHASHED BY CONTACTING
THE MANUFACTURER.

SAFETY PRECAUTIONS

Safety is everybody's business and is based on your use of good common sense.  All situations or circumstances cannot
always be predicted and covered by established rules.  Therefore, use your past experience, watch out for safety hazards
and be cautious.

Содержание HLS-120

Страница 1: ...PERSONAL INJURY DO NOT REMOVE REPAIR OR REPLACE ANY ITEM ON THIS DRYER WHILE IT IS UNDER PRESSURE NEVER OPERATE THIS DRYER ABOVE THE RATED OPERATING CONDITIONS OPERATION ABOVE SPECI FIED CONDITIONS WI...

Страница 2: ...INJURY AND OR EQUIPMENT DAMAGE MAY RESULT MAKE SURE THAT ALL EQUIPMENT BEING USED TO LIFT THE DRYER IS CAPABLE OF LIFTING THE WEIGHT OF THE DRYER IF THE DRYER IS TO BE TRANSPORTED OVERHEAD MAKE SURE T...

Страница 3: ...S 80 HLS 120 HLS 150 ELECTRICAL Nema 4 Electrical enclosure Standard 115V 115V 1PH 50 60Hz Optional 230V 230V 1PH 50 60Hz DESICCANT Material Activated Alumina 1 8 2 5 MM Bead type Quantity Per Tower L...

Страница 4: ...to start up 4 3 REMOTE PURGE EXHAUST PIPING To reduce the noise during purging and tower depressurization this dryer was supplied with a muffler for installation on the purge exhaust valve If the soun...

Страница 5: ...RSONAL INJURY AND DAMAGE TO THE DRYER WILL OCCUR IF THE DRYER IS CONNECTED TO A POWER SOURCE OTHER THAN THE VOLTAGE LISTED ON THE DATA TAG WHEN INSTALLING THE ELECTRICAL CONNECTIONS FOR THIS DRYER COM...

Страница 6: ...d the purge air which was vented to atomosphere earlier in the cycle is now used to repressurize the regenerated tower FIGURE 6A PNEUMATIC SCHEMATIC 6 1 2 CHANGEOVER DEPRESSURIZATION STAGE Tower chang...

Страница 7: ...ressurize both towers of the dryer until there is demand on the compressor The Hold LED will light if the dryer is wired as described and the compressor is not running IMPORTANT Operating this dryer o...

Страница 8: ...ING THE DUST AND PROLONGED CONTACT WITH THE SKIN FIRST AID IN CASE OF EYE CONTACT IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES CONSULT A PHYSICIAN Take dryer off stream followin...

Страница 9: ...ions correct them and condition the bed following the procedures in Section 5 3 ARE THE BYPASS VALVES OPEN OR LEAKING Check the valves if installed Repair or replace if faulty IS THE POWER ON AND RUN...

Страница 10: ...ntrol Air Filter Element control air filter Desiccant Activated Alumina 1 8 dia 25 pail Control Box complete Circuit Board only Membrane Panel Pressure Switch HLS 55 115V PART NO 14 2073 26 6516 26 65...

Страница 11: ...rol Air Filter Element control air filter Desiccant Activated Alumina 1 8 dia 25 pail Control Box complete Circuit Board only Membrane Panel Pressure Switch HLS 120 115V PART NO 14 2075 26 6515 26 651...

Страница 12: ...FROM IMPROPER GROUNDING CAN CAUSE INJURY OR DEATH GROUND UNIT AND RELATED EQUIPMENT ACCORDING TO NATIONAL ELECTRICAL CODE AND LOCAL REGULATIONS WARNING WARNING READ THE OPERATOR S MANUAL BEFORE START...

Отзывы: